Part Number IS220PPRFH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS220PPRFH1A is a PROFIBUS Master Gateway pack developed by GE.
The PROFIBUS Master Gateway (PPRF) pack is a PROFIBUS DPV0, Class 1 master that maps I/O from PROFIBUS slave devices to I/O Ethernet Mark VIe controllers. The module includes a processor board shared by all Mark VIe distributed I/O modules and an acquisition carrier board outfitted with a Hilscher GmbH COM-C PROFIBUS communication module. IS220PPRFH1A Functional Description A PROFIBUS RS-485 interface is provided by the COM-C module via a DE-9 D-sub receptacle connector. It functions as a PROFIBUS DP master, with transmission rates ranging from 9.6 KBaud to 12 MBaud and up to 125 slaves, each with 244 bytes of inputs and outputs. Other IO packs use the same dual I/O Ethernet connection configuration. In the hot-backup mode, however, two PPRFs are used, one as the active PROFIBUS master communicating with slave devices and the other in a passive, stand-by mode, ready to become the active master in the event of an active master failure.
Features The following redundancy options are supported by the PPRF: One I/O pack with one Ethernet connection (no redundancy) Dual I/O Ethernet connections on a single I/O pack Dual I/O Ethernet connections on the hot-backup I/O pack Compatibility The PROFIBUS Master Gateway Terminal board (SPIDG1A) is used to install the PPRF and provide an electronic ID. Its only connection is to the PPRF, as the PROFIBUS connection is made to the DE-9 D-sub receptacle connector exposed on the PPRF's side. On the PPRF, indicator LEDs provide visual diagnostics. The number of I/O packs used in a signal path is referred to as the control mode: Simplex employs a single I/O pack and one or two network connections. Hot backup employs two I/O packs, each with two network connections. IS220PPRFH1A Installation Firmly secure the SPID terminal board. Insert the PPRF directly into the terminal board connector. Repeat steps 1 and 2 with a second SPID and PPRF for hot-backup configurations.
Use the threaded inserts next to the Ethernet ports to mechanically secure the packs. The inserts connect to a terminal board-specific mounting bracket. Adjust the bracket so that no right angle force is applied to the DC-37 pin connector between the pack and the terminal board. This adjustment is required only once during the product's lifetime Depending on the system configuration, connect one or two Ethernet cables. The pack can be used with either port. Standard practice is to connect ENET1 to the network associated with the R controller when using dual connections; however, the PPRF is not sensitive to Ethernet connections and will negotiate proper operation over either port. Insert the PROFIBUS cable into the DE-9 D-sub receptacle connector and secure it. PROFIBUS must be terminated on either end, according to PROFIBUS specifications. Connect power to the connector on the pack's side. It is not necessary to insert the connector with the cable's power disconnected. The PPRF includes an inherent soft-start capability that regulates current inrush during power application. Configure the I/O pack and PROFIBUS as needed using the ToolboxST application.IO PACK, PROFIBUS INTERFACE
Related models
0880001-01
104X905BA603
12A0-0103-A3
12HFA51A42H
12HGA11J52
269 PLUS-D/O-100P-125V
369-A200
369B1860G0026
369B1860G0030
369-C100
369-C101
369-HI-0-0-0-0
369-HI-0-M-F-E-0
369-HI-R-M-0-0-0-E
369-HI-R-M-0-E-0
369-HI-R-M-0-P-0-E
application area
Industries such as petroleum, coal, metal ore, nonmetal ore and wood;
Industries of basic materials, power and fuel.
Metal smelting and processing, coking and coke, chemistry, chemical raw materials, cement, wood-based panels and power, petroleum and coal processing industries;
Machinery and equipment manufacturing industry, metal structure, cement products, chemical fertilizer and pesticide industry.
Wind power generation, thermal power generation, hydropower generation, nuclear power generation and other energy sources; For example, thermal power in China is mainly distributed in the northern coal-producing areas of China, mainly using coal. Hydropower is mainly distributed in the source area of south China, which is rich in hydropower. The distribution of nuclear power is not very typical.
Power transmission, including AC power transmission and DC power transmission: For example, the largest power transmission project in China is the West-to-East Power Transmission Project.
Substation; Power distribution; Electricity, electrical machinery and equipment manufacturing.
These are the application fields of our products.
About Xiamen kongjiang automation technology co., ltd:
Xiamen kongjiang automation technology co., ltd is a technology-based entity company established on may 11th, 2017, located in Xiamen, Fujian province. The company is mainly engaged in the sales of imported industrial control parts, electrical engineering design, installation, programming, debugging, construction and other businesses. The company has an experienced and well-trained technical team, which is committed to providing customers with services such as electrical automation system development, automatic upgrading and transformation of the original production line, energy
User name | Member Level | Quantity | Specification | Purchase Date |
---|
Add: Building F05, High-tech Software Park, Xiamen City, Fujian Province
Tel: 0592-5211302
Mobile: 17750019513 (WhatsApp)
Email: yy4291644@gmail.com
ivy@kongjiangauto.com
Website: https://www.abb-sis.com