KONG -Y
NameDescriptionContent
Location:
product
IS220PRTDH1A Manufacturer General Electric Country
❤ Add to collection

IS220PRTDH1A Manufacturer General Electric Country

IS220PRTDH1A
U.S.$38887.00
U.S.$2985.00
U.S.$2835.75
U.S.$2776.05
Weight:7.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS220PRTDH1A

Part Number IS220PRTDH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS220PRTDH1A is a Resistance Temperature Device Input Module manufactured and designed by General Electric as part of the Mark VIe Series used in distributed control systems. 

An RTD input terminal board and one or more I/O Ethernet networks are connected electrically by the Resistance Temperature Device (RTD) Input (PRTD) pack. An acquisition board dedicated to the thermocouple input function is included in the pack, along with a processor board that is shared by all Mark VIe distributed I/O packs. Up to eight RTD inputs can be supported by the I/O pack, while the TRTD terminal boards can support up to sixteen RTD inputs. A DC-37 pin connector that links directly to the terminal board connector for the pack, as well as a three-pin power input, are used for input. There are two RJ45 Ethernet connectors for the output. Indicator LEDs are used to display visual diagnostics. 

 IS220PRTDH1A Compatibility The RTD input terminal boards TRTDH1D, H2D, and SRTD board are all compatible with PRTDH1A, but the DIN-rail mounted DRTD board is not. 

The compatibility information is provided in the table below. One I/O pack and one or two network connections are used in simplex. Two I/O packs with one or two network connections are used by Dual. Three I/O packs with one network connection each are used by TMR. The TRD input circuit is galvanically isolated by the PRTD. This necessitates modifications to the TRTDH1D and TRTDH2D boards' terminal board transient protection. The board's H1D version offers filtering that is compatible with the PRTD standard scan rate. When the rapid scan rate of PRTD is chosen, the H2D version of the terminal board offers less filtering to enable proper performance. Although there won't be any physical harm, if PRTD is mounted on an earlier version of the TRTD board, an incompatibility will be detected. IS220PRTDH1A Installation Securely mount the desired terminal board. Directly connect one or two PRTDs to the connections on the terminal board (for simplex control of eight or 16 RTDs). Utilizing the threaded inserts next to the Ethernet ports, mechanically secure the packs. The inserts attach to the terminal board type-specific mounting bracket. It is important to position the bracket such that the DC-37 pin connector between the terminal board and the pack is not subjected to a right angle force. Only one adjustment should be necessary during the lifespan of the product. Depending on the system configuration, connect one or two wires to ensure optimal operation across either port. It is customary to link ENET1 to the network connected to the R controller when dual connections are employed. Connect the connector on the side of the pack to provide electricity to the battery. The I/O pack includes a built-in soft-start feature that limits current inrush when power is applied, so it is not essential to unplug the cable before connecting it. To customize the I/O pack as appropriate, use the ToolboxST* application. Processor Board Operation The I/O pack or module function-specific acquisition board is connected to the processor board. The soft-start circuit ramps up the voltage available on the processor board when input power is applied. The processor reset is turned off and the local power supply is turned on in order. After finishing self-test routines, the processor loads application code from flash memory that is particular to the I/O pack or module type. To verify that the application code, acquisition board, and terminal board are correctly matched, the application code reads the board ID information. When there is a good match, the processor makes an effort to start Ethernet connections by asking for a network address. The dynamic host configuration protocol (DHCP), which is the industry standard, and the terminal board's unique identifier are both used in the address request. Following Ethernet startup, the CPU runs the application, programs the on-board logic, and permits the acquisition board to start working.

The whole circuitry required to enable the I/O pack to function from one or two Ethernet inputs is contained in the processor application code. Both network pathways are constantly active when two Ethernet inputs are used. The I/O pack or module operation will not be hampered by a failure of either network, and the functioning network connection will reveal the failure. Compared to a traditional hot-backup system, where the second port is only used when the primary port fails to function, this configuration is more fault tolerant. The processor's Ethernet ports automatically negotiate between half-duplex and full-duplex operation at speeds between 10 MB/s and 100 MB/s. The processor board is common to all Mark VIe Ethernet I/O packs or modules. It contains the following: A quick processor with RAM and flash memory is number one. 

Two plugs for entirely independent 10/100 Ethernet ports Hardware reset and watchdog timer circuit A sensor for internal temperature LEDs that indicate the status The capacity to read IDs on other boards and electronic identification An input power connector with a current limiter and a gentle start Local power supplies, which also include monitoring and sequencing IS220PRTDH1A Diagnostics A power-up self-test that examines the hardware on the CPU board, Ethernet ports, RAM, and Flash memory. Constantly checking if the internal power supply is operating properly Verifying that the hardware set matches by comparing the electronic ID data from the CPU, acquisition, and terminal boards, then checking that the application code loaded from flash memory is appropriate for the hardware set. Hardware limit checking for each RTD type is based on predetermined (non-configurable) high and low levels that are placed close to the working range's edges. The input is no longer examined once this limit is reached, and a logic signal is set instead. A composite diagnostic alarm, L3DIAG PRTD, referring to the entire board is generated if the hardware limits for any one of the eight inputs are reached. Information about each diagnosis is available from the toolbox. Individual diagnostic signals may be latched, and the RESET DIA signal may be used to reset them. System limit testing for each RTD input is done using customizable high and low levels. These restrictions, which can be adjusted for enable/disablement and latching/non-latching, can be utilized to trigger alarms. The out-of-limit signals are reset via RESET SYS. The toolbox offers information on each diagnosis in detail. The diagnostic signals can be individually latched and, if they become healthy, reset with the RESET DIA signal.IO PACK, RTD IN/OUT

  • PACIFIC SCIENTIFIC PC800 PC832 PC830 Series Digital Brushless Servo Drive
  • PSS41S-3FDCTSAA Triconex DCS System Access Application Driver for Field Device Controller 280
  • Alstom controller of ICP232 029.359325
  • DEIF DU-2/MKIII Paralleling And Protection Unit General information
  • ABB 3ADT220134R0001 SDCS-COM-81 board 10MBd
  • ABB 3BHB006338R0002 UNS 0881a-P,V2:GDI PCB assembled *PB
  • ABB GRID BREAKER UNIT GBU72 3BHE055094R0002 / 3BHE031197R0001 / 3BHB030310R0001
  • ABB PCS6000 PRODUCT FAMLIY
  • ALSTOM SPU232.2 controller UNIT 029.366 817 029366817 SPU2322
  • ABB AO2000-LS25 Operator’s Manual 41/24-109 EN Rev. 3
  • Alstom EPSD-0603 series Circuit board redundancy architecture
  • ABB GJR2390200R1411 83SR04R1411 Control Module Universal
  • GE Digital Energy Hydran 201Ti Mark IV Essential DGA monitoring
  • Bender ISOMETER®IRDH275 IRDH275B
  • ABB 3BSE017235R1 PXAH 401 Operator Unit
  • HIMax-TECHNICALFACTS
  • Power supply CP-E 24/1.25 ABB
  • ABB NSIN0070-5 (IP23) 3ABD00024914
  • ABB 1VCR000993G0002 PCB card
  • ABB 2CSG524000R2021 TMD-T4/96 Temperature control unit
  • 3BHE014135R0011 UAD149A0011 ABB AC800PEC series
  • Alstom CT94360/01 signal regulator
  • MISP2-2W-T00-1000 GE Measurement & Control Solutions
  • DEIF AGC150 independent generator controller
  • DEIF AGC-4 10102264.10 Advanced generator set controller
  • ABB Plantguard Communications P8151B P8110B
  • ABB Plantguard series P8403 Digital input module
  • ABB 3BHE041343R0102 PCD530A102 Comm. Contr. & Meas. (CCM)
  • ABB P8431 TMR analog input module
  • ABB P129740-002 SIO Assembly,Smart Weight,Interface,Pre-
  • 3BHB007441P0001 LDSTA-01 ABB inverter control CPU driver board
  • ABB LD series LDMTR-01 63940135F I/O module
  • ABB 7525A38G01 SCV-MR 600:5 7525A38
  • ABB C86-94639 Sensor Module Assembly,PCBA,TUV
  • Melcher W Series 125, 250 Watt AC-DC and DC-DC DIN-Rail Converters Convert Select LWN2660-6E-G
  • ABB NDBU-95C; Star connection branching unit (9 outputs= 9 pcs 10 Mb)
  • ABB A2C 250 TMF 250-2500 4p F F 1SDA066792R1
  • ABB YC E1.2..E6.2-XT7M 220-240 VAC/DC 1SDA073687R1
  • ABB Electromagnetic flowmeter WaterMaster
  • ABB Model: S-PKZ2, ZM-25 -8- PKZ2,ZM-16-PKZ2,PS201PRE ,PKZMO-10-T
  • ABB 3BHE004385R0001 UNS 0884a, V1:Current Sensor 2000A
  • ABB 3AXD50000182992 ZCU-14 PACKED SP; CONTROL UNIT
  • ABB INDUSTRIALDRIVES UCU-22, UCU-23 andUCU-24control units
  • ABB LDMU series LDMUI-01 61320946C Overview of interface module
  • ABB HIEE410506P104 UAC389 Processor module
  • ABB BN5930.48 24VDC safety relay
  • ABB 3BHE006373R0101 XVC769 AE101 PC board
  • ABB 58967441 NTAC-02; PULSE ENCODER INTERFACE
  • ABB NEMA full voltage power devices
  • ABB 800xA Device Management and Fieldbus Overview
  • ABB FOUNDATION™ Fieldbus Linking Device LD 810HSE Ex V1.0
  • ABB 3BSE017235R1 PXAH 401 Operator unit
  • ABB Drives series SCYC51213 63911607C DRIVER BOARD
  • SCYC51220 63901075C ABB control panel
  • ABB HL000986P0006 High density digital input/output module
  • 3BHB004791R0101 ABB medium voltage drive ACS2000 series
  • ABB 3BHB009175R0001丨3BHB005922R0001 UNS 0880a-P,V1:CIN PCB completed
  • MTA025 EBG92026 ABB MTA series current transformers
  • ABB AF400-30-11-70 1SFL577001R7011
  • ABB 12556917-738385 RADOX GKW cable
  • ABB THYRISTOR MODUL WE-73-10/CH 64421956
  • ABB 969.105EBG 540KKS166899 automatic system
  • ABB CH-3185 3BHL000986P1006 Abbability 800xa automation system
  • ABB 500CMP04 HE401314/0001 1MRB150051R1 power-supply module
  • ABB 500TTM02 1MB150021R01161HF930712X010 control panel
  • ABB 500MBA01 1MRB150003R0002 1MRB200053/L operation manual
  • ABB 500MBA02 1MRB150003R000/B Safety rules
  • ABB 500MBA02 1MRB150003R0003 1MRB200053/M Full range of power modules
  • ABB AC 800PEC system 3BHE023784R1023 PP D113 B01-10-150000
  • ABB 4LA41100102V1.2 KB2 Display Unit
  • ABB 60 - 65 A perfect fit
  • ABB PPD113 B03-23-100110 3BHE023584R2334 AC800PEC Control Systems
  • ABB 3BHE028122R0001 XFD213A control panel
  • ABB 3BSE030220R1 CI854AK01 PROFIBUS-DP/V1 interface
  • AO845A ABB Ability™ System 800xA® hardware selector
  • ABB 64666606 DSMB-02C control panel
  • ABB 68444161 IGBT FS450R12KE3/AGDR-71C
  • ABB CTB810 HN800/CW800 Communications Terminal Board connects to LEFT side of MB810
  • ABB Ability™ Symphony® Plus SD Series controller HPC800
  • ABB 3BSE018293R1 DSAO-120A Analog Output Board 8 Channels
  • ABB REA101-AAA ARC PROTECTION
  • ABB 3BSC950262R1 TK851V010 Connection Cable, 1m
  • ABB I/O Systems - S800 I/O DI810
  • SOE - Infi 90 Series INSEM01 | ABB - DCS Center
  • ABB 3BSE010535R1 PM645B Processor Module
  • ABB Tension Electronics PFEA 111, 112, 122 and 113 User Manual
  • ABB 3HNA018564-001 DSQC355B/ANALOG IO
  • ABB 3BSE020512R2 AI801-eA S800 I/O Systems
  • ABB HIEE200130R0002 AF C094 AE02 ARCnet control panel
  • AC800M series HIEE300885R1 PPC380AE01 ABB
  • ABB SNAT604IFS REV.B code: 61029052 5761861-2B control panel
  • AC 800M - Controller Hardware - ABB
  • CP430 Installation and Operation Manual ABB,1SBC159103M0202
  • ABB 3BSE000355R1 DSPU 131 MA200 Interface Board
  • ICSI16E1 | ABB Procontic CS 31 Input Module Binary
  • MSR04X1 Wiring Accessories | Service and tools | ABB - ABB Group
  • EtherNet/IP™ to Remote I/O or DH+ Gateway AN-X2-AB-DHRIO
  • Protection Cards for AMS 6500 Classic Systems EMERSON
  • EMERSON AMS Trex™ Device Communicator
  • EMERSON AMS 2140 Machinery Health™ Analyzer
  • EMERSON CSI 2140 Machinery Health Analyzer
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB GJR2391500R1210 81EU01H-E / 81EU01 Input Module universal
  • AC31 mit AC1131 Teil 16: Systemtechnik Serie 40/50
  • ABB IEPAS02 POWER MODULE +5, +/-15, 24
  • ABB 5SHX0660F0001 Asymmetric Thyristor IGCT series
  • ABB HIER464920P0001 CURRENT RELAY,UNS 0017A-P
  • ABB 3AFA408368 IMA MODULE
  • ABB SWISS MADE 5SHY5045L0020
  • ABB 3BSE042237R1 PP836 Panel 800 Control System
  • ABB AC 800M Controller Hardware PM866
  • ABB 3BSC950192R1 TK850V007 CEX-Bus Extension Cable
  • ABB 3BHE023784R2330 PP D113 B01-23-111000: AC 800PEC
  • AO801 ABB Ability™ System 800xA® hardware selector
  • ABB EXC3BSE018106R1 CI855K01 MB 300 Dual Ethernet Port Kit
  • 57160001-AZ DSTD 150 Connection Unit ABB
  • RET670 - Transmission transformer protection 丨ABB
  • ABB EL3000 series EasyLine Continuous Gas Analyzers Model EL3020 EL3040
  • Analog signal converters Overview ABB 1SVR011718R2500
  • ABB Procontic CS 31 series ICST08A9
  • ABB ControlIT AC 800PEC Control System PPD512A10-150000
  • ABB REU615E_D VOLTAGE PROTECTION AND CONTROL RELAY
  • UFC911B108 3BHE037864R0108 ABB Main control board
  • ABB REM610C55HCNN02 Motor protection relay REM610
  • ABB 3BSE013231R1 TU811 TU811V1 Compact Module Termination Unit 1x8 signal terminals.
  • ABB GOP2 G2010A 10.4ST Interface Panel B416302
  • ABB IMRIO02R IMRIO02,Remote I/O Module
  • ABB Relion 610 Series