KONG -Y
NameDescriptionContent
Location:
product
IS220PRTDH1B IO PACK RTD IN/OUT
❤ Add to collection

IS220PRTDH1B IO PACK RTD IN/OUT

IS220PRTDH1B - IO PACK, RTD IN/OUT
U.S.$53580.00
U.S.$43580.00
U.S.$41401.00
U.S.$40529.40
Weight:8.990KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS220PRTDH1B - IO PACK, RTD IN/OUT

IS220PRTDH1B IO PACK RTD IN/OUT

Part Number IS220PRTDH1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS220PRTDH1B is a RTD Input Pack manufactured and designed by General Electric as part of Mark VIe Series distributed control system. The Resistance Temperature Device (RTD) Input (PRTD) pack interfaces one or two I/O Ethernet networks with an RTD input terminal board. The pack includes a processor board that is shared by all Mark VIe distributed I/O packs as well as an acquisition board dedicated to the thermocouple input function. IS220PRTDH1B Functional Description The PRTD pack only supports the simplex operation. The pack is powered by three-pin power input and a DC-37 pin connector that connects directly to the associated terminal board connector. Dual RJ45 Ethernet connectors are used for output. LED indicator lights provide visual diagnostics. The I/O pack can handle up to eight RTD inputs and the TRTD terminal boards can handle up to 16 RTD inputs. Compatibility The number of I/O packs used in a signal path is referred to as the control mode: Simplex employs a single I/O pack and one or two network connections. Dual employs two I/O packs with one or two network interfaces. TMR employs three I/O packs, each with one network connection. The galvanic isolation of the TRD input circuit is provided by the PRTD. This necessitates changes to the terminal board transient protection, which is available on the TRTDH1D and TRTDH2D boards. The H1D version of the board includes filtering that is compatible with the PRTD's standard scan rate. When the fast scan rate of the PRTD is selected, the H2D version of the terminal board provides less filtering to allow proper performance. The incompatibility will be reported if the PRTD is mounted on an earlier revision of the TRTD board, but no physical damage will occur. IS220PRTDH1B Processor Features The processor board is linked to an acquisition board dedicated to the function of the I/O pack or module. When input power is applied, the soft-start circuit increases the voltage available on the processor board. The local power supplies are turned on in sequence, and the processor reset is disabled. After finishing self-test routines, the processor loads application code specific to the I/O pack or module type from flash memory. The application code reads board ID information to ensure that the application code, acquisition board, and terminal board are all correctly matched. When there is a good match, the processor attempts to establish Ethernet communications, beginning with a network address request. 

The address request makes use of the industry-standard dynamic host configuration protocol (DHCP) and the terminal board's unique identification. Following Ethernet initialization, the processor programs the on-board logic, runs the application, and allows the acquisition board to begin operation. The processor application code contains all of the logic required for the I/O pack to operate from one or two Ethernet inputs. When two Ethernet inputs are used, both network paths are always active. A failure of either network will not affect the operation of the I/O pack or module, and the failure will be indicated by the working network connection. This configuration is more fault-tolerant than a traditional hot-backup system, which uses the second port only when the primary port fails. The Ethernet ports on the processor auto-negotiate between 10 MB/s and 100 MB/s speeds, as well as between half-duplex and full-duplex operation. Auto-Reconfiguration The Auto-Reconfiguration feature allows the operator to replace I/O packs without having to manually reconfigure each pack or module. When the controller detects an I/O pack booting with a different configuration and the Auto-Reconfiguration feature is enabled, a reconfiguration file is automatically downloaded from the controller to the I/O pack. The bootload, baseload, firmware, and parameters are all reconfigured. Unless it already has the latest version, each I/O pack is updated with the current configuration that matches the configuration used by the controller. Analog Input Hardware The RTD terminal board provides eight three-wire RTD inputs to the PRTD input board. Each RTD, which can be grounded or ungrounded, receives a 10 mA dc multiplexed (not continuous) excitation current from the pack. With a maximum two-way cable resistance of 15, the eight RTDs can be located up to 300 meters (984 feet) from the turbine I/O cabinet. The pack's A/D converter samples each signal and excitation current four times per second in normal mode and 25 times per second in fast mode, with a time sample interval related to the power system frequency.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

IS230TNPAH2A

F650BABF2G0LOSHE

IS220PAICH1A

DS215TCQAG1BZZ01A

IS215UCVEH2AE

IS200SDIIH1ADB MRP683026

IS200TREGH1BDB

IS220PDOAH1B

IS220PAICH1A

IC697CPM925

IS200TREAH2AED

UR6DH

HR911103A   VMIVME-7750的RJ45

  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • Reason RT431 GPS Precision-Time Clock GE
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch
  • GE Reason S20 Managed Ethernet Switches
  • GE Gridcom DIP.net
  • Central Control Station at Jaenschwalde mineLausitzer Braunkohle AG, Germany 2000
  • ABB Ability™ System 800xA Advant® Master S400 I/O to S800 I/O Evolution
  • ABB with Advant Controller 400 series
  • Advant™Automation with MOD 300™ Software
  • Bently 2300/20 and 2300/25 2300 Vibration Monitors
  • ABB NGC8206 Natural Gas Chromatograph Dual Unit
  • MOTOROLA MVME2400 TM VME Processor Modules
  • 5320 Series Foxboro DCS Control Network Ethernet Equipment
  • ExtremeSwitching™ 5420 Series
  • WOODWARD EGCP-3 Engine Generator Control Package LS (Load Sharing)
  • 5520 Series Universal Edge/Aggregation-Switch Platform
  • X440-G2 Series
  • EMERSON FloBoss™ S600 Flow Manager Specification Sheet
  • KONGSBERG RAIV400 Remote Analogue Input, Voltage
  • RMP420-Remote Multipurpose Input/Output Kongsberg
  • 610 serie ABB Feeder Protection REF610 Product Guide
  • Triconex 3351S2 Controller Features
  • HBRF Megamax – Emax2 Air Circuit Breaker ABB
  • ABB MEASUREMENT & ANALYTICS | DATA SHEET LS4000 Diode laser analyzer
  • Pressductor Pillowblock Load Cells Vertical Measuring PFCL 201 User manual
  • PARKER BFR5K Series
  • AC 900F controller ABB
  • Uniop ePAD05 and ePAD06 Technical description
  • Hitachi ABB Communication Unit 560CMR02
  • MOTOROLA MVME5500 Series VME Single-Board Computer
  • ABB Symphony Plus SD Series HPC800 controller
  • ABB AC800M Controller Hardware System
  • ABB AC800M PROFIBUS DP Installation System
  • ABB Freelance 800F AC800F Control systems
  • ABB Compact control system replaces PLC AC700F
  • abb Triguard SC300E 3BNP004720R101 TMR Safety Products
  • ABB Distributed busbar protection REB500
  • ABB Advant Controller 400 series