KONG -Y
NameDescriptionContent
Location:
product
IS220PSCAH1B IO PACK SERIAL COMM, BPPC BASED
❤ Add to collection

IS220PSCAH1B IO PACK SERIAL COMM, BPPC BASED

IS220PSCAH1B
U.S.$5920.00
U.S.$74255.00
U.S.$70542.25
U.S.$69057.15
Weight:2.880KG
Quantity:
(Inventory: 5)
Buy now
Add to cart
Description
IS220PSCAH1B

Part Number IS220PSCAH1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS220PSCAH1B is a Serial Communications I/O Pack designed by General Electric as a part of the Mark VIe series. The Serial Communication Input/Output (PSCA) pack interfaces one or two I/O Ethernet networks with a serial communications terminal board. The pack includes a processor board that is shared by all Mark* VIe distributed I/O packs as well as a serial communications board. The communications board has six serial transceiver channels, each of which can be configured to meet RS-232, RS-422, or RS-485 half duplex standards. The pack is powered by three-pin power input and two RJ45 Ethernet connectors. Output is via a DC-62 pin connector that is directly connected to the associated terminal board connector. On Simplex Networks, one of the Ethernet ports can be used to support Ethernet Modbus communication. Visual diagnostics are provided through indicator LEDs. IS220PSCAH1B Installation To install the PSCA pack Securely mount the terminal board of choice. Insert one PSCA pack directly into the terminal board connector. Use the threaded inserts next to the Ethernet ports to mechanically secure the packs. The inserts connect to a terminal board-specific mounting bracket. The bracket should be positioned so that no right-angle force is applied to the DC-62 pin connector between the pack and the terminal board. The adjustment should only be needed once during the product's lifetime. Depending on the system configuration, connect one or two Ethernet cables. The pack can be used with either port. The PSCA is not sensitive to Ethernet connections and will negotiate proper operation over either port if dual connections are used. Connect the pack to power by plugging in the connector on the pack's side. Because the I/O pack has the inherent soft-start capability that controls current inrush on power application, it is not necessary to disconnect power from the cable before plugging it in. Configure the I/O pack as needed using the ToolboxST application. Processor All Mark VIe Ethernet I/O packs or modules share the same processor board. It includes the following: Two fully independent 10/100 Ethernet ports with connectors Hardware watchdog timer and reset circuit Internal temperature sensor Status-indicating LEDs Electronic ID and the ability to read IDs on other boards Soft start/current limiter on the input power connector Local power supplies, including sequencing and monitoring The processor board is linked to an acquisition board dedicated to the function of the I/O pack or module. When input power is applied, the soft-start circuit increases the voltage available on the processor board. The local power supplies are turned on in sequence, and the processor reset is disabled. After finishing self-test routines, the processor loads application code specific to the I/O pack or module type from flash memory. The application code reads board ID information to ensure that the application code, acquisition board, and terminal board are all correctly matched. With a good match, the processor attempts to establish Ethernet communications, beginning with a network address request. The address request employs the industry-standard dynamic host configuration protocol (DHCP) and the terminal board's unique identification. Following Ethernet initialization, the processor programs the on-board logic, executes the application, and allows the acquisition board to start up. Auto-Reconfiguration The Auto-Reconfiguration feature allows the operator to replace I/O packs without having to manually reconfigure each pack or module. When the controller detects an I/O pack booting with a different configuration and the Auto-Reconfiguration feature is enabled, a reconfiguration file is automatically downloaded from the controller to the I/O pack. The bootload, baseload, firmware, and parameters are all reconfigured. Unless it already has the latest version, each I/O pack is updated with the current configuration that matches the configuration used by the controller. While an Auto-Reconfiguration is running, the controller will not allow a reboot until the Auto-Reconfiguration is complete. Other I/O pack downloads cannot be started while it is being Auto-Reconfigured. Auto-Reconfiguration only performs diagnostics if an I/O pack is already running. The Component Editor in the ToolboxST application allows you to enable or disable auto-reconfiguration. If necessary, the operator can manually reconfigure each pack or module. Terminal board and controller auto-reconfiguration is not supported. When a terminal board is replaced, the I/O pack must be reconfigured manually. Install or replace the I/O pack according to the instructions in the Installation section. When you turn on the power, the I/O pack boots up and the Auto-Reconfiguration process begins. It sends a signal to the controller indicating that it requires an IP address and configuration. The controller searches the I/O pack for existing files to determine whether a reconfiguration is required. The controller will then begin downloading the IP address and reconfiguration files. When the download is finished, the controller notifies the I/O pack. The I/O pack reboots, runs a self-diagnostic test, and returns to service. Data Flow from IS220PSCAH1B to Controller There are two types of data flow from PSCA to the Mark VIe controller: fixed I/O and Modbus I/O. The smart pressure transducers and the Kollmorgen脗庐 electric drive data are linked to fixed I/O. Every frame, this data is completely processed, just like conventional I/O. The frame rate required is 100 Hz. The.tre file is used to map these signals into signal space, and they have individual health bits, system limit checking, and offset/gain scaling. Modbus I/O refers to the I/O associated with Modbus ports. Because of the volume of these signals, they are not completely processed every frame; instead, they are packaged and transferred to the Mark VIe controller via a special service over the IONet. This can support up to 2400 bytes at 4 Hz or 9600 bytes at 1 Hz, or a combination of the two. This is known as second class I/O, and coherency is only at the signal level. Health bits are assigned at the device level, the Mark VIe controller expands for all signals, and there is no system limit checking. Before a signal is declared unhealthy, it must time out twice in a row. All communication issues are announced using diagnostic messages. Power Management The 28 V input circuit of the I/O pack includes power management. Soft start is provided by the management function to control current inrush during power application. Following power application, the circuit implements a fast current limit function to prevent a pack or terminal board failure from propagating back onto the 28 V power system. The green PWR LED indicator will illuminate when power is present and functioning properly. When the current limit function is activated, the PWR LED will remain dark until the problem is resolved. Connectors A DC-62 pin connector on the I/O pack's underside connects directly to a discrete output terminal board. The primary system interface is an RJ-45 Ethernet connector on the pack side labeled ENET1. The redundant or secondary system interface is a second RJ-45 Ethernet connector on the pack side labeled ENET2. IS220PSCAH1B Features The PSCA provides the electrical interface between one or two I/O Ethernet networks and the serial communication terminal board. The pack contains a processor board common to all Mark VIe distributed I/O packs and the serial communication board. The communication board contains 6 serial transceiver channels, each of which can be individually configured to comply with RS-485 standards inputs to the pack is through dual RJ-485 Ethernet connectors and 3-Pin power inputs output is through a DC-62 pin connector that connects directly with the associated terminal board connector. One of the ethernet ports can be used to support ethernet Modbus communication on simplex networks visual diagnostics are provided through indicator LEDs on local diagnostics serial communications are possible through an infrared port.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

IC600CB527M

DS3800XTFP1E1C

IS200DSPXH1DBC

IC693MDL640

IS220PDIAH1A 336A4940CSP1

IS200EGPAG1BCA

IC698CRE030

IC693CPU341

IC697CPX772

IS210BPPBH2BMD

IS200ERDDH1ABA

IS220PDOAH1A

DS200SDCIG1ABA

IC698CPE020

531X303MCPBBG1

IC687BEM731-AB

IC697CPM925

VMIVME-4140

DS200DMCBG1AED

IS200VCRCH1B

IC687RCM711

IS200TVIBH2BBB

IC670ALG310-JA

IC697CHS790

IS210SAMBH2AA

DS200SHVMG1AFE

IC660ELB912

IS220PPRFH1A

  • PACIFIC SCIENTIFIC PC800 PC832 PC830 Series Digital Brushless Servo Drive
  • PSS41S-3FDCTSAA Triconex DCS System Access Application Driver for Field Device Controller 280
  • Alstom controller of ICP232 029.359325
  • DEIF DU-2/MKIII Paralleling And Protection Unit General information
  • ABB 3ADT220134R0001 SDCS-COM-81 board 10MBd
  • ABB 3BHB006338R0002 UNS 0881a-P,V2:GDI PCB assembled *PB
  • ABB GRID BREAKER UNIT GBU72 3BHE055094R0002 / 3BHE031197R0001 / 3BHB030310R0001
  • ABB PCS6000 PRODUCT FAMLIY
  • ALSTOM SPU232.2 controller UNIT 029.366 817 029366817 SPU2322
  • ABB AO2000-LS25 Operator’s Manual 41/24-109 EN Rev. 3
  • Alstom EPSD-0603 series Circuit board redundancy architecture
  • ABB GJR2390200R1411 83SR04R1411 Control Module Universal
  • GE Digital Energy Hydran 201Ti Mark IV Essential DGA monitoring
  • Bender ISOMETER®IRDH275 IRDH275B
  • ABB 3BSE017235R1 PXAH 401 Operator Unit
  • HIMax-TECHNICALFACTS
  • Power supply CP-E 24/1.25 ABB
  • ABB NSIN0070-5 (IP23) 3ABD00024914
  • ABB 1VCR000993G0002 PCB card
  • ABB 2CSG524000R2021 TMD-T4/96 Temperature control unit
  • 3BHE014135R0011 UAD149A0011 ABB AC800PEC series
  • Alstom CT94360/01 signal regulator
  • MISP2-2W-T00-1000 GE Measurement & Control Solutions
  • DEIF AGC150 independent generator controller
  • DEIF AGC-4 10102264.10 Advanced generator set controller
  • ABB Plantguard Communications P8151B P8110B
  • ABB Plantguard series P8403 Digital input module
  • ABB 3BHE041343R0102 PCD530A102 Comm. Contr. & Meas. (CCM)
  • ABB P8431 TMR analog input module
  • ABB P129740-002 SIO Assembly,Smart Weight,Interface,Pre-
  • 3BHB007441P0001 LDSTA-01 ABB inverter control CPU driver board
  • ABB LD series LDMTR-01 63940135F I/O module
  • ABB 7525A38G01 SCV-MR 600:5 7525A38
  • ABB C86-94639 Sensor Module Assembly,PCBA,TUV
  • Melcher W Series 125, 250 Watt AC-DC and DC-DC DIN-Rail Converters Convert Select LWN2660-6E-G
  • ABB NDBU-95C; Star connection branching unit (9 outputs= 9 pcs 10 Mb)
  • ABB A2C 250 TMF 250-2500 4p F F 1SDA066792R1
  • ABB YC E1.2..E6.2-XT7M 220-240 VAC/DC 1SDA073687R1
  • ABB Electromagnetic flowmeter WaterMaster
  • ABB Model: S-PKZ2, ZM-25 -8- PKZ2,ZM-16-PKZ2,PS201PRE ,PKZMO-10-T
  • ABB 3BHE004385R0001 UNS 0884a, V1:Current Sensor 2000A
  • ABB 3AXD50000182992 ZCU-14 PACKED SP; CONTROL UNIT
  • ABB INDUSTRIALDRIVES UCU-22, UCU-23 andUCU-24control units
  • ABB LDMU series LDMUI-01 61320946C Overview of interface module
  • ABB HIEE410506P104 UAC389 Processor module
  • ABB BN5930.48 24VDC safety relay
  • ABB 3BHE006373R0101 XVC769 AE101 PC board
  • ABB 58967441 NTAC-02; PULSE ENCODER INTERFACE
  • ABB NEMA full voltage power devices
  • ABB 800xA Device Management and Fieldbus Overview
  • ABB FOUNDATION™ Fieldbus Linking Device LD 810HSE Ex V1.0
  • ABB 3BSE017235R1 PXAH 401 Operator unit
  • ABB Drives series SCYC51213 63911607C DRIVER BOARD
  • SCYC51220 63901075C ABB control panel
  • ABB HL000986P0006 High density digital input/output module
  • 3BHB004791R0101 ABB medium voltage drive ACS2000 series
  • ABB 3BHB009175R0001丨3BHB005922R0001 UNS 0880a-P,V1:CIN PCB completed
  • MTA025 EBG92026 ABB MTA series current transformers
  • ABB AF400-30-11-70 1SFL577001R7011
  • ABB 12556917-738385 RADOX GKW cable
  • ABB THYRISTOR MODUL WE-73-10/CH 64421956
  • ABB 969.105EBG 540KKS166899 automatic system
  • ABB CH-3185 3BHL000986P1006 Abbability 800xa automation system
  • ABB 500CMP04 HE401314/0001 1MRB150051R1 power-supply module
  • ABB 500TTM02 1MB150021R01161HF930712X010 control panel
  • ABB 500MBA01 1MRB150003R0002 1MRB200053/L operation manual
  • ABB 500MBA02 1MRB150003R000/B Safety rules
  • ABB 500MBA02 1MRB150003R0003 1MRB200053/M Full range of power modules
  • ABB AC 800PEC system 3BHE023784R1023 PP D113 B01-10-150000
  • ABB 4LA41100102V1.2 KB2 Display Unit
  • ABB 60 - 65 A perfect fit
  • ABB PPD113 B03-23-100110 3BHE023584R2334 AC800PEC Control Systems
  • ABB 3BHE028122R0001 XFD213A control panel
  • ABB 3BSE030220R1 CI854AK01 PROFIBUS-DP/V1 interface
  • AO845A ABB Ability™ System 800xA® hardware selector
  • ABB 64666606 DSMB-02C control panel
  • ABB 68444161 IGBT FS450R12KE3/AGDR-71C
  • ABB CTB810 HN800/CW800 Communications Terminal Board connects to LEFT side of MB810
  • ABB Ability™ Symphony® Plus SD Series controller HPC800
  • ABB 3BSE018293R1 DSAO-120A Analog Output Board 8 Channels
  • ABB REA101-AAA ARC PROTECTION
  • ABB 3BSC950262R1 TK851V010 Connection Cable, 1m
  • ABB I/O Systems - S800 I/O DI810
  • SOE - Infi 90 Series INSEM01 | ABB - DCS Center
  • ABB 3BSE010535R1 PM645B Processor Module
  • ABB Tension Electronics PFEA 111, 112, 122 and 113 User Manual
  • ABB 3HNA018564-001 DSQC355B/ANALOG IO
  • ABB 3BSE020512R2 AI801-eA S800 I/O Systems
  • ABB HIEE200130R0002 AF C094 AE02 ARCnet control panel
  • AC800M series HIEE300885R1 PPC380AE01 ABB
  • ABB SNAT604IFS REV.B code: 61029052 5761861-2B control panel
  • AC 800M - Controller Hardware - ABB
  • CP430 Installation and Operation Manual ABB,1SBC159103M0202
  • ABB 3BSE000355R1 DSPU 131 MA200 Interface Board
  • ICSI16E1 | ABB Procontic CS 31 Input Module Binary
  • MSR04X1 Wiring Accessories | Service and tools | ABB - ABB Group
  • EtherNet/IP™ to Remote I/O or DH+ Gateway AN-X2-AB-DHRIO
  • Protection Cards for AMS 6500 Classic Systems EMERSON
  • EMERSON AMS Trex™ Device Communicator
  • EMERSON AMS 2140 Machinery Health™ Analyzer
  • EMERSON CSI 2140 Machinery Health Analyzer
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB GJR2391500R1210 81EU01H-E / 81EU01 Input Module universal
  • AC31 mit AC1131 Teil 16: Systemtechnik Serie 40/50
  • ABB IEPAS02 POWER MODULE +5, +/-15, 24
  • ABB 5SHX0660F0001 Asymmetric Thyristor IGCT series
  • ABB HIER464920P0001 CURRENT RELAY,UNS 0017A-P
  • ABB 3AFA408368 IMA MODULE
  • ABB SWISS MADE 5SHY5045L0020
  • ABB 3BSE042237R1 PP836 Panel 800 Control System
  • ABB AC 800M Controller Hardware PM866
  • ABB 3BSC950192R1 TK850V007 CEX-Bus Extension Cable
  • ABB 3BHE023784R2330 PP D113 B01-23-111000: AC 800PEC
  • AO801 ABB Ability™ System 800xA® hardware selector
  • ABB EXC3BSE018106R1 CI855K01 MB 300 Dual Ethernet Port Kit
  • 57160001-AZ DSTD 150 Connection Unit ABB
  • RET670 - Transmission transformer protection 丨ABB
  • ABB EL3000 series EasyLine Continuous Gas Analyzers Model EL3020 EL3040
  • Analog signal converters Overview ABB 1SVR011718R2500
  • ABB Procontic CS 31 series ICST08A9
  • ABB ControlIT AC 800PEC Control System PPD512A10-150000
  • ABB REU615E_D VOLTAGE PROTECTION AND CONTROL RELAY
  • UFC911B108 3BHE037864R0108 ABB Main control board
  • ABB REM610C55HCNN02 Motor protection relay REM610
  • ABB 3BSE013231R1 TU811 TU811V1 Compact Module Termination Unit 1x8 signal terminals.
  • ABB GOP2 G2010A 10.4ST Interface Panel B416302
  • ABB IMRIO02R IMRIO02,Remote I/O Module
  • ABB Relion 610 Series