IS220PTCCH1A

Part Number IS220PTCCH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS220PTCCH1A is a thermocouple input module developed by General Electric. 

It serves as a bridge, connecting I/O Ethernet networks to a thermocouple input terminal board through a sophisticated electrical interface. Thermocouple Input Module is a sophisticated and versatile component of the Mark VIe series, designed to provide precise temperature monitoring in a wide range of industrial applications. Its compatibility with various thermocouple types, scalability in handling inputs, and user-friendly features make it a valuable asset in control and monitoring systems where temperature control and measurement are paramount. Features At the core of the module is a processor board that is common to all Mark VIe distributed I/O packs. This central processing unit acts as the brain of the module, orchestrating data acquisition and communication. 

It forms the foundation upon which the module's functionality is built. To cater to the precise requirements of thermocouple inputs, the module is equipped with a thermocouple input-specific acquisition board. This dedicated hardware ensures accurate and reliable measurement of temperature variations, essential for applications where temperature control is critical. The module boasts impressive scalability, offering flexibility in handling thermocouple inputs. In a Simplex setup with the TBTCH1B terminal board, each module can manage up to 12 thermocouple inputs. When two modules are employed in conjunction, this configuration allows for the monitoring of a total of 24 inputs. Accommodates various thermocouple types, including E, J, K, S, and T thermocouples, as well as mV inputs. It encompasses a broad mV input range from -8 mV to +45 mV, ensuring compatibility with a wide array of temperature measurement devices. 

To power the module, it features dual RJ45 Ethernet ports and a three-pin power input, simplifying power connection and providing redundancy for reliable operation. The module's output interface is a DC-37 pin connector that directly interfaces with the terminal board connector, enabling a secure and efficient connection. For real-time status monitoring and diagnostics, the module incorporates indicator LEDs. These LEDs provide visual feedback, allowing operators to assess the module's operational status and swiftly identify any potential issues. Compatibility Dual RJ45 Ethernet ports and three-pin power input are used to power the pack. 

The output is a DC-37 pin connector that connects directly to the terminal board connector. Indicator LEDs are used to display visual diagnostics. It accepts E, J, K, S, and T thermocouples as well as mV inputs. IS220PTCCH1A Installation Secure the Terminal Board: Begin by selecting the terminal board that is suitable for your application. The terminal board provides the interface between the I/O pack and your system. Ensure that it is securely mounted and positioned as needed for your specific setup. Connect the PTCC I/O Pack: Connect the I/O to the terminal board connectors directly. 

This step establishes the electrical connection between the I/O pack and your system. Make sure the connections are secure to prevent any loose or intermittent contact issues. Mechanical Securing of Packs: To physically secure the I/O in place, use the threaded studs located close to the Ethernet ports. This step ensures that the I/O pack remains firmly attached to the terminal board and prevents any unintentional disconnection due to vibrations or movement. Ethernet Connections: Depending on your system configuration and networking requirements, you may need to connect one or two Ethernet wires to the I/O pack. You have the flexibility to use either port for network connectivity. If you opt for dual connections, make sure to connect ENET1 to the network linked with the R controller for proper network communication. Power Connection: Connect the I/O pack to the power source by plugging in the connector on the side of the pack. It is important to note that the I/O pack incorporates an inbuilt soft-start feature. This feature regulates the current inrush when power is applied, eliminating the need to disconnect the connection before plugging it in. 

This simplifies the power connection process while maintaining system stability. Configuration with ToolboxST Application: Once the I/O pack is physically installed and connected, the final step involves configuring the pack as needed for your application. This can be accomplished using the ToolboxST application, which provides a user-friendly interface for configuring and customizing the I/O pack's settings to meet your specific requirements. Operation Processor The processor board is connected to an acquisition board that is appropriate to the purpose of the I/O pack or module. The soft-start circuit ramps up the voltage available on the processor board when input power is applied. The processor reset is removed, and the local power supplies are sequenced on. The CPU runs self-test procedures before loading application code from flash memory that is particular to the I/O pack or module type. To verify that the application code, acquisition board, and terminal board are all correctly matched, the application code reads board ID information. Auto-Reconfiguration The Auto-Reconfiguration capability enables the operator to swap I/O packs without having to manually reconfigure each pack or module. When the Auto-Reconfiguration functionality is activated, a reconfiguration file is automatically downloaded from the controller to the I/O pack when the controller detects an I/O pack booting with a different configuration. Analog Input Hardware The thermocouples linked to the terminal board send 12 signals at mV levels to the PTCC input board. Six differential multiplexers, the main multiplexer, and a 16-bit analog to digital converter deliver the digital data to the next processor board make up the analog input portion. 

 Diagnostics The following self-diagnostic tests are carried out by the pack: Power-Up Self-Test: Upon powering up, the pack initiates a comprehensive self-test. This test encompasses an array of critical hardware components, including RAM (Random Access Memory), flash memory, Ethernet ports, and the processor board. By examining these components, the pack can promptly detect any issues or discrepancies that might hinder its performance. Power Supply Monitoring: The pack maintains constant vigilance over its internal power supply. It continually monitors power levels to ensure that the device is receiving the requisite voltage and current to operate optimally. This proactive monitoring safeguards against power-related failures or disruptions. Electronic ID Verification: To confirm the integrity of the hardware setup, the pack verifies the electronic identification information of the terminal board, acquisition board, and processor board. This verification process ensures that the hardware components are consistent and that no unauthorized changes or replacements have occurred. 

Relay Drive Validation: The pack performs a thorough check of the commanded state of each relay drive and cross-references it with the feedback received from the command output circuit. This cross-validation is critical for verifying that the relays are operating as expected, preventing potential issues caused by relay malfunction. Relay Board Feedback Processing: The pack reads and processes feedback specific to the relay boards. This step is instrumental in evaluating the performance of relay boards and identifying any irregularities or issues that may need attention or maintenance. Multicast Communications Monitoring: When configured with a PGEN pack, the system continuously monitors multicast communications. 

This real-time monitoring ensures the integrity and effectiveness of the communication system, helping to detect any anomalies, delays, or disruptions in the transmission of data.IO PACK, THERMOCOUPLE




  • 81EU50 83SR50 88TK50 Universal I/O and control modules 丨ABB
  • GJR2390200R1411 83SR04R1411 Control Module Universal
  • ABB INSUMMCU2 MCU2A02V24 INSUM® PROFIBUS Gateway Manual SW 2.1
  • ABB REF542 series 1VCR007346 G0028 Function and configuration
  • ABB 216AB61 HESG324013R101 Control Panel-Specifications
  • ABB 216EA61B HESG448230R1/G
  • 216VC62A HESG324442R112/F 丨ABB
  • 500PSM03A 1MRB150038R1 series丨ABB Power control panel
  • REG216, CompactREC216 Numerical Generator ProtectionNumerical Control Unit
  • ABB Panel 800 series 3BSE092980R1 PP886 Standard Panel 15"
  • 500CIM05 1MRB150077R1/B ABB
  • 500CPU05 1MRB150081R1/E ABB-Module
  • 500SCM01 1MRB200059/C 1MRB15004R0001丨ABB Star coupler module
  • ABB SYNCHROTACT ® 5
  • ABB 3BHB006716R0277 SYN 5302a-Z,V277: Auto dual channel Syn
  • ABB Pressductor-PillowBlock Load cells series PFCL201
  • ABB UNS4684A-P,V.1 HIEE305114R00R0001 control panel
  • Tension Electronics PFEA 111, 112, 122 and 113 丨ABB
  • ABB PFRL101C-1.0KN 3BSE023316R1002 Web Tension Measurement
  • 1VCF750090804 HMI SUE 3000 (110...220 V) ABB
  • 57120001-AT DSAO 110 ABB
  • S100 I/O Modules DSAO 120 57120001-EY 丨ABB
  • Advant Controller 500 series 500BIO01 1MRB150005R0001 1MRB200060/E ABB
  • 3BHE023784R2530 PP D113 B01-25-111000: AC 800PEC Static Excitation Systems›UNITROL 6000 X-power
  • ABB EXC3BSE008105R1 SC560 Exchange
  • HR Series Turbine control systems SD Series remote I/O ABB
  • HR Series (Harmony Rack) I/O RSPASI23
  • ABB SPBRC400 Controller with Expanded Memory
  • E3HAB8101-18 Modules Drive System 丨ABB
  • ABB 3BHL000986P7000 LXN 1604-6, 27V 500W
  • ABB REF615_series_ Feeder protection and control
  • ACS 6000 series Medium voltage AC drives for control of 3–27 MW motors up to 3.3 kV
  • I/O Systems - S800 I/O series-ABB
  • SPAJ 140 C Series ABB
  • INCLUDING PFSK 113 7625013-S 丨ABB
  • AC 800PEC The high-performance control system for model-based design
  • HKQCS PARTS ON LINE 129740-002 ABB
  • UNITROL 6000 X-power 3BH022294R0103 GFD233A103
  • AO810 AO810V2 - ABB Ability™ System 800xA® hardware
  • Elastimold® molded vacuum reclosers – MVR MVR 0.44-10KA
  • AC 800M series PM865 3BSE030193R1 discontinued products
  • 1MRK000838-HA ABB RXIDK 2H series
  • ABB 605 series
  • Feeder protection REJ601 BD446NN1XG
  • ABB SAFT183VMC expansion module board unit specifications
  • 3BHB004661R0101 KU C711 AE; GATE UNIT POWER S GUSP
  • PRC3BSE066490R1 PM856AK01 Processor Unit
  • SM560-S (1SAP280000R0001) AC500 CPU Firmware SM560-S-FD-4
  • 769137 Detector 13CO2 10% (Uras26) ABB control unit
  • AC500 CPU Firmware
  • 0002-07-2-00001-01 BMXS Science Module (ADC)
  • Safety instructions for AC500 PLCs 3ADR025003M9903
  • ABB I/O Systems - S800 I/O AI830A
  • AC500-eCo PM556-TP-ETH; PLC-eCo CPU PM556-TP-ETH 3ABD00034186
  • ABB I/O Remote Unit ICSF08D1 CS31 CS 31 Procontic FPR3323101R1012-L
  • WMDOLT2-A75(65KA)6E 1TGE106812P0001 System circuit breaker Drawer type
  • Technical analysis of ABB 1MRK002247-Apr04 protection relay module
  • PFTL101A 0.5KN 3BSE004160R1 Pressductor PillowBlock horizontal load cell
  • 3BSE004166R1 PFTL 101A-1.0kN, Load cell
  • SD Series I/O Interface cRBX01 2VAA008424R1
  • ABB 3BSC950193R1 TB850 CEX-Bus Terminator
  • LDGRB-01 3BSE013177R1 Analysis of module technology
  • GRBTU 3BSE013175R1 Communication gateway module
  • 3BHE037864R0101P UF C911 B101: CVMI2B -PROGRAMMED-
  • Panel 800 version 6
  • 3BHE024577R0101 PPC907BE ACS 2000 Drive Manuals
  • I/O Systems - 3BSE028602R1 DO880 - ABB Ability™ System
  • ABB YPP110A 3ASD573001A1 application controller
  • 57520001-FY DSCS 150 GCOM Communication Unit
  • AC 800M - Processor Modules 3BSE018157R1 PM861AK01 Processor Unit
  • 3BSE069274R1 PP877K Key Panel 10.4" Panel 800
  • 3BSE069449R1 (CI854BK01) PROFIBUS DP-V1
  • 3BSE018135R3 CI858 ABB Ability System 800xA
  • P3BSE042238R1 PANEL 800-PP846 PRE-OWNED
  • ABB NDBU-95 NDBU - DDCS branching unit
  • X10-14210201 605-A53842-002 Abaco Systems specification
  • HIMax®System Bus Module X-SB01 Manual
  • GE Intelligent PlatformsVersaMax* PLC User Manual 151X1235DB15SA03
  • MOTOROLA FLN3524/FCN6650 adapter power supply
  • SYMAP ECG Ship Monitoring And Control Panel 12-36V DC
  • 9200 and 74712 Seismoprobe Velocity Transducers
  • 3500/91 EGD Communication Gateway Module 161204-01
  • 1900/55 Fan Monitor: Operation Manual
  • 3701/55 ADAPT (ESD) Emergency Shutdown Device 323174-01
  • 3300 XL 8 mmProximity Transducer System 330104-00-05-10-02-CN
  • MR series (Melody rack) input and output›CAC 10-P 3BDH000610R1
  • 57160001-ADF DSDP 170 inc. Pos. and Speed meas.
  • S100 I/O - Modules DSDO 115K12 Digital Outp, 32 ch, 24
  • AC 400 Power SA168K16 Basic Power Supply and Switch
  • 3BSE018290R1 DSAI 133A Analog Input Board 32 Channels
  • 3BSE011180R1 Advant Controller 450 Version 2.3 PM511V08 Processor Module
  • 3BSC950164R30 S100 I/O Cables DSTK 221L3 Cable Assembly ,Ribbon Cable,
  • 3BSE020419R1 S100 I/O - Modules DSAO 120AK01 Analog Output 8 ch 12 Bit,
  • REF3BSE012545R1 CI546 VIP Communication Interface
  • 3BSE004772R1 Advant Controller 410 Version 1.5 Communication Modules
  • AC 400 - Communication Modules 3BSE018283R1 CI522A
  • Bently Nevada 3500/05-01-03-00-00-00 Rack Module
  • 3500 Series Status System Bently Nevada 135473-01 Vibration Monitoring Module
  • 330130-045-00-00 Bently Nevada 3300 XL Extension Cable
  • Bently Nevada 330100-90-01 3300 XL 8 mmProximity Transducer System
  • Bently Nevada 149369-01 Key components of 3500 mechanical protection system
  • 106M1081-01 Universal AC Power Input Module Description
  • PR6423 8mm Eddy Current Sensor
  • PR6424 16mm Eddy Current Sensor
  • VIBRO-METER 200-560-000-112 Communication board
  • VIBRO-METER 200-510-111-035 Mechanical protection card
  • Bently Nevada 22810-01-05-50-02 Stop production status confirmation
  • 330180-91-05 Bently Nevada 5/8 mm Proximitor Sensor
  • HIEE300690R0001 AR C093 AE01 Relay Output Card
  • Multilin UR Family Proven, State-of-the-Art Protection & Control Systems
  • Multilin 8 Series Innovative protection and control relay platform
  • Multilin 3 Series Intuitive industrial and utility protective relays for feeders, motors and transformers
  • MVME177P TM Single-Board Computer MOTOROLA
  • ABB DRIVE SERVICES Spare Parts Service product description
  • Cradlepoint IBR200 Product life cycle announcement
  • CC PUIO3 series Honeywell CC-PAOH01 analog output module
  • Honeywell TC-OAV081 Analog output module p/n 97062778
  • Honeywell TC-PRR021 Redundant module DHL, UPS fast delivery
  • Honeywell TC-FXX102 TC-FX10210 controller
  • Honeywell TK-PRS021 C200 Product overview
  • Honeywell ML6420A3007-E master controller
  • Parts on HONEYWELL automaton S4560M S4560M1036 boiler-Diesel boiler
  • Honeywell PK 81181 Installation Instructions for the
  • Honeywell 2MLR-CPUH/F-CC MasterLogic-200 Specifications and Technical Data
  • 3BSE018161R1 PM864AK01 Processor Unit ABB
  • ABB 3BHE017628R0102 PPD115A102 club.
  • FANUC WHEDCO 78004655 System controller module
  • FANUC WHEDCO 78004661 Analysis I/O module