KONG -Y
NameDescriptionContent
Location:
product
IS420UCSCH1B - UCSC CONTROLLER, QUAD CORE
❤ Add to collection

IS420UCSCH1B - UCSC CONTROLLER, QUAD CORE

IS420UCSCH1B - UCSC CONTROLLER, QUAD CORE
U.S.$5920.00
U.S.$1569.00
U.S.$1490.55
U.S.$1459.17
Weight:5.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS420UCSCH1B - UCSC CONTROLLER, QUAD CORE

Part Number is420ucsch1b Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS420UCSCH1B is a Quad Core Controller manufactured and designed by General Electric. It is a part of the Mark VIe Series used in GE Distributed Control Systems. It is a version of the quad-core controller that is used with the QNX Neutrino operating system. TMR, Simplex, and Dual redundancy are supported by the component. The QNX operating system is used in high-speed, highly reliable industrial applications. Another type of technology used on this controller is Embedded Field Agent (EMA) technology, which allows Predix cloud-based applications and possibly web applications to be applied over a stable connection, allowing real-time data to be delivered to the connecting controllers. IS420UCSCH1B Features The controller comes with 4 GB of DDR3-1333 SDRAM, which is a type of memory used in computers and other digital devices for high-speed data storage. The controller has 5 Ethernet ports, which allow it to connect to other devices and networks for data transfer and communication. The controller uses ControlST as its Human-Machine Interface (HMI), which is a software application used to interact with and control the device. The Mark VIe quad-core controller runs high-speed, high-reliability industrial applications using real-time hypervisor technology and QNX Neutrino, a real-time, multi-tasking operating system (OS). PredixTM cloud-based apps and/or locally hosted web applications are applied through a secure connection and delivered real-time data using embedded field agent (EFA) technology. A software package tailored to the UCSCH1x controller's use is preloaded. It leverages IONet interfaces as a turbine or balance of plant (BoP) controller and runs Mark VIe firmware and applications. Only supporting Mark controls I/O packs and controllers, IONet is a private special-purpose Ethernet. To synchronize the clocks of the I/O modules and controllers to within 100 microseconds, IEEE 1588 protocol is employed through the IONet interfaces. With the IONet connections, external data is transmitted to and from the controller's control system database. To the I/O modules, this also refers to process inputs and outputs. The UCSC controller lacks any application I/O, in contrast to conventional controllers that host application I/O on a backplane. Operation The operation of the system involves several key aspects, including the installation of the ToolboxST application, configuring the UDH network communication, and establishing the necessary IP address for communication with site HMIs. Here is an expanded explanation of these operations: ToolboxST Application Installation: To facilitate configuration and management tasks, the ToolboxST application is typically installed on a minimum 4 GB unencrypted flash drive. This flash drive serves as the storage medium for the application and contains the necessary files and settings. The ToolboxST application provides a user-friendly interface for configuring various aspects of the system, including network communication. UDH Network Configuration: The UDH (User Datagram Header) network is utilized for communication within the system. During the configuration process, the ToolboxST application is employed to define the communication parameters for the UDH network. This involves setting up network addresses, ports, protocols, and other relevant settings. The configuration ensures that the control module can establish reliable and secure communication with other devices and systems within the network. Default IP Address: By default, the control module is assigned the IP address 192.168.101.111. This IP address serves as the initial configuration for the module's network connectivity. However, it is important to note that this default IP address may need to be modified to match the specific requirements and setup of the site or network where the system is deployed. Configuring Relevant UDH IP Address: In order for the control module to effectively communicate with the site HMIs (Human-Machine Interfaces), it must be configured with the relevant UDH IP address. This IP address is specific to the UDH network and enables seamless communication between the control module and the site HMIs. Through the ToolboxST application, the control module's IP address can be customized and set to the appropriate value that aligns with the network configuration and addressing scheme of the site. Virtual Network The virtual network feature in controllers is a powerful capability provided by the hypervisor, enabling seamless communication and data exchange between virtual machines (VMs) running on the same physical machine or across multiple physical machines in the network. The virtual network functions similarly to a conventional Ethernet network, facilitating data transmission between VMs just as physical Ethernet networks facilitate data transfer between physical machines. Virtual network plays a crucial role in connecting different components of the system and enabling efficient data transfer. Specifically, it facilitates data exchange between the Embedded Field Agent (EFA) and the Mark VIe control, both of which run as separate VMs on the UCSCH1 controller. Here's how the virtual network enables data communication between the EFA and the Mark VIe control: EFA and Mark VIe Control VMs: In the UCSCH1 controller, the EFA and the Mark VIe control are both running as virtual machines (VMs) within the same hypervisor environment. Each VM operates independently, emulating separate computing environments within the same physical machine. Data Transfer through Virtual Network: When data needs to be exchanged between the EFA and the Mark VIe control, it is transmitted through the virtual network provided by the hypervisor. The virtual network efficiently routes the data between the two VMs, enabling seamless and fast communication. Connection to the Cloud: The EFA, being an essential component for remote monitoring and management, requires a connection to the cloud for data exchange with remote servers or cloud-based applications. This connection allows the EFA to send data to the cloud and receive commands or updates from the cloud-based systems. Physically Managed Switch for Network Division: To maintain proper network segregation and security, a physically managed switch is used to divide the networks. The physically managed switch creates distinct network segments, ensuring that the Mark VIe control, which contains sensitive control data, remains isolated from the cloud network. This network division helps protect critical control systems from potential external threats. By leveraging the virtual network, the controller achieves efficient and secure data communication between its different VMs, enabling seamless coordination and control of various components in the system. The integration of a physically managed switch adds an extra layer of security, ensuring the safety and integrity of critical control systems while allowing the EFA to establish connections with cloud-based systems for enhanced functionality and remote monitoring capabilities. Ethernet Ports/Controller Communications Support 3 IONet ports (R/S/T) for I/O module communications (simplex, dual, TMR, and Shared I/O supported). ENET 1 - EGD/UDH communications to ToolboxST PC, HMIs, UCSCS2A Safety controller, and GE PACSystems products. Modbus TCP Slave, Read/Write. ENET 2 - Secondary UDH communications, Modbus TCP Slave and OPC UA. IICS Cloud port for Embedded Field Agent (EFA). Module Ports The control module is equipped with various ports on its front and bottom panels, serving different purposes and enabling connectivity and functionality. Here is an expanded explanation of each port: Ethernet Ports: The front panel of the module features five Ethernet ports. These ports are used for establishing network connections and enabling communication with other devices or systems within the network. Predix Connectivity Port: Located on the bottom panel, this Ethernet port is specifically designated for connectivity to Predix, a cloud-based platform developed by GE. It facilitates data exchange and integration with Predix for enhanced monitoring and analytics capabilities. USB Ports: The module has two USB ports, which are primarily used for specific functions. These ports are typically utilized during the initial setup of the UDH (User Datagram Header) network IP address. Additionally, they can be utilized for a restore function, allowing for the restoration of the module's configuration or software. COM Port: The COM port is a serial communication port that employs an RJ-45 connector and operates at a speed of 115200 bits per second (bit/s). The configuration for this port is 8N1, which denotes eight data bits, no parity bit, and one stop bit. This port does not employ flow control and is commonly used by GE for troubleshooting purposes in the field. It supports the serial redirection of UEFI-setup, facilitating configuration adjustments and troubleshooting activities. Display Port: The module features a Display Port, although it is disabled after the system's startup. The Display Port is typically used to connect an external display device for video output, but its functionality is limited or deactivated once the module is operational. microSD Port: While the module includes a microSD port, it is not currently supported. The microSD port is designed to accommodate a microSD card, which can be utilized for storage purposes. However, in this particular system, the functionality of the microSD port is not enabled or actively supported. Product Attributes Altitude for Normal Operation: Designed to operate within an altitude range of 0-1000 meters. It can function reliably in environments with varying atmospheric pressure, ranging from 101.3 to 89.9 kilopascals (kPa). This attribute ensures that the module can maintain optimal performance even at different altitudes. Dimensions with Mounting: The module has specific dimensions when considering its mounting. It has a height of 8.03 inches, a depth of 5.99 inches, and a width of 2.17 inches when properly mounted. These dimensions provide guidance for installation and integration into the overall system architecture. HMI (Human-Machine Interface): Supports ControlST V07.00.00C or later as its human-machine interface. The HMI facilitates interaction between the module and the human operator, allowing for intuitive control, monitoring, and configuration of the system. Memory Type: The module is equipped with 4 GB DDR3-1333 SDRAM memory. This type of memory is commonly used for storing and processing data within the module. The 4 GB capacity provides sufficient space for efficient data management and enables the module to handle complex control algorithms and calculations effectively. Number of Ethernet Ports: Features a total of six Ethernet ports. Five of these ports are located on the front panel, providing convenient access for networking purposes. Additionally, one Ethernet port is available on the bottom of the module, specifically designed for Predix connectivity. These Ethernet ports facilitate seamless communication and data exchange between the module and other devices or systems within the network. NVSRAM (Nonvolatile Static Random-Access Memory): The module incorporates NVSRAM, which includes 3067 nonvolatile program variables, 64 totalizers, and 338 forces. NVSRAM allows the module to retain critical information, such as program variables and configuration settings, even during power outages or system failures. This attribute ensures data integrity and reliability, crucial for applications where data loss is not acceptable. Platform Configuration Supported Features: Supports EFA (Embedded Functionality Automation), Embedded EtherCAT (Ethernet for Control Automation Technology), and Embedded PPNG (Predix Process & Notification Gateway) as its platform configuration features. These advanced networking capabilities enhance the module's connectivity, compatibility, and overall performance in complex industrial control systems. Storage Temperature: The module is designed to withstand a wide range of storage temperatures, from -40 to 85 degrees Celsius. This attribute allows the module to be stored safely in environments with extreme temperature conditions, ensuring its durability and long-term reliability. Diagnostics The Control Module's circuit cards include system (software) limit checking, high/low (hardware) limit checking, and comprehensive diagnostics for abnormal hardware conditions. System limit checking consists of two limits for each analog input signal, which can be set with the I/O Configurator in engineering units for high/high, high/low, or low/low. Each input limit can be configured for latching/non-latching and enable/disable. System limit checking logic outputs are generated per frame and stored in the database (signal space) for use in control sequencing and alarm messages. Each analog input has high/low (hardware) limit checking, with typically two occurrences required before an alarm is triggered. These limits are not programmable and are chosen to be outside the normal control requirements range but within the linear hardware operational range (before the hardware reaches saturation). The software maintenance tools provide access to diagnostic messages for hardware limit checks and all other hardware diagnostics for the card (Control System Toolbox). In the database, each card has a composite logic output, and another logic output indicates a high/low (hardware) limit fault of any analog input or the associated communications for that signal. Characteristics HMI: ControlST - The human-machine interface (HMI) used in this system is ControlST. ControlST is a software or hardware component that allows users to interact with and control the system. Trip Solenoid Rating: 125 V dc - The trip solenoid used in the system has a rating of 125 volts direct current (V dc). The trip solenoid is an electromechanical device that is used to trip or close circuit breakers or other devices in response to specific conditions. Span: -8 mV to +45 mV - The span refers to the range of values that can be measured or controlled. In this case, the system has a span of -8 millivolts (mV) to +45 mV. This indicates that the system can measure or control signals within this voltage range. Power supply voltage: 28 V dc - The power supply voltage for the system is 28 volts direct current (V dc). This voltage is used to provide power to the various components of the system. Voltage Range: 18 - 32 VDC - The system operates within a voltage range of 18 to 32 volts direct current (VDC). This indicates that the system is designed to function properly within this voltage range. Platform Configuration Supported Features: EFA, Embedded EtherCAT, and Embedded PPNG - The platform configuration of the system supports several features, including EFA (Electronic Function Blocks), Embedded EtherCAT (Ethernet for Control Automation Technology), and Embedded PPNG (Powerful Programmable Numeric Gateway). These features enhance the system's capabilities and functionalities. NVSRAM: 3067 Nonvolatile Program Variables, 64 Totalizers, and 338 Forces - The system has NVSRAM (Nonvolatile Static Random Access Memory) that can store 3067 nonvolatile program variables, 64 totalizers, and 338 forces. NVSRAM is a type of memory that retains its stored information even when power is removed from the system. Number of Ethernet Ports: 6 - The system is equipped with six Ethernet ports. Ethernet ports are used for connecting the system to a network, allowing for communication with other devices or systems. Altitude for Normal Operation: 0-1000 m at 101.3 to 89.9 kPa - The system is designed to operate normally within an altitude range of 0 to 1000 meters. The atmospheric pressure range for normal operation is 101.3 to 89.9 kilopascals (kPa). HMI: ControlST V07.00.00C or Later - The specific version of the ControlST HMI used in the system is V07.00.00C or later. This indicates the minimum version requirement for compatibility and functionality with the system. Cable Separation and Routing When it comes to cable separation and routing in control systems, it is important to consider certain factors to ensure optimal system performance. One significant consideration is the prevention of electrical noise interference caused by different voltage levels in the cabling. Electrical noise can disrupt the operation of microprocessor-based control systems, leading to malfunctions or unreliable performance. To mitigate the risks associated with electrical noise interference, it is essential to follow proper guidelines and recommendations during the installation of cables. Before proceeding with the cable installation, it is advisable to consult the relevant manuals and documentation provided by the manufacturer or system designer. These manuals often contain specific instructions and precautions for cable installation in various scenarios. If the installation site presents unique circumstances or if the guidelines mentioned in the documentation cannot be met, it is crucial to seek further guidance or clarification. During the planning stages of system revamps or upgrades, adherence to level rules is highly recommended. Level rules refer to established standards and guidelines for cable separation and routing in control systems. These rules ensure that cables are appropriately organized and spaced to prevent interference and optimize system performance. By considering level rules during the planning process, the chances of a trouble-free installation and proper application of the control system are significantly increased. By following these guidelines and best practices, potential issues arising from electrical noise interference can be minimized. Proper cable separation and routing help maintain the integrity of the control system, ensuring reliable and efficient operation. It is important to prioritize these considerations during the design, installation, and maintenance phases to maximize the performance and longevity of the control system. Environment Features The Mark VIe control system cabinet should be installed in an environmentally controlled room or in the control room itself. The cabinet should be installed in a location where the floor surface allows for attachment in only one plane (a flat, level, and continuous surface). The mounting hardware is supplied by the customer. Lifting lugs are provided, and lifting cables must not exceed 45掳 from the vertical plane if used. Finally, the cabinet has a door handle that can be locked for security. Interconnecting cables can enter the cabinet from the top or bottom via removable access plates. Convection cooling of the cabinet necessitates the sealing of conduits to access plates. Furthermore, the temperature of the air passing through the conduit must be within the acceptable range. This is true for both the top and bottom access plates.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

IC697MDL740

IC670PBI001

IC698CHS117C

DS200TCQAG1BHF

IS200AEPCH1ABC

IC697MDL250

IC697MDL250

760-P1-G1-S1-LO-A20-R

SR489-P5-LO-A20-E

IC670CHS001E

IC697MDL653

IS200VTCCH1CBB

VMIVME-4150

  • 81EU50 83SR50 88TK50 Universal I/O and control modules 丨ABB
  • GJR2390200R1411 83SR04R1411 Control Module Universal
  • ABB INSUMMCU2 MCU2A02V24 INSUM® PROFIBUS Gateway Manual SW 2.1
  • ABB REF542 series 1VCR007346 G0028 Function and configuration
  • ABB 216AB61 HESG324013R101 Control Panel-Specifications
  • ABB 216EA61B HESG448230R1/G
  • 216VC62A HESG324442R112/F 丨ABB
  • 500PSM03A 1MRB150038R1 series丨ABB Power control panel
  • REG216, CompactREC216 Numerical Generator ProtectionNumerical Control Unit
  • ABB Panel 800 series 3BSE092980R1 PP886 Standard Panel 15"
  • 500CIM05 1MRB150077R1/B ABB
  • 500CPU05 1MRB150081R1/E ABB-Module
  • 500SCM01 1MRB200059/C 1MRB15004R0001丨ABB Star coupler module
  • ABB SYNCHROTACT ® 5
  • ABB 3BHB006716R0277 SYN 5302a-Z,V277: Auto dual channel Syn
  • ABB Pressductor-PillowBlock Load cells series PFCL201
  • ABB UNS4684A-P,V.1 HIEE305114R00R0001 control panel
  • Tension Electronics PFEA 111, 112, 122 and 113 丨ABB
  • ABB PFRL101C-1.0KN 3BSE023316R1002 Web Tension Measurement
  • 1VCF750090804 HMI SUE 3000 (110...220 V) ABB
  • 57120001-AT DSAO 110 ABB
  • S100 I/O Modules DSAO 120 57120001-EY 丨ABB
  • Advant Controller 500 series 500BIO01 1MRB150005R0001 1MRB200060/E ABB
  • 3BHE023784R2530 PP D113 B01-25-111000: AC 800PEC Static Excitation Systems›UNITROL 6000 X-power
  • ABB EXC3BSE008105R1 SC560 Exchange
  • HR Series Turbine control systems SD Series remote I/O ABB
  • HR Series (Harmony Rack) I/O RSPASI23
  • ABB SPBRC400 Controller with Expanded Memory
  • E3HAB8101-18 Modules Drive System 丨ABB
  • ABB 3BHL000986P7000 LXN 1604-6, 27V 500W
  • ABB REF615_series_ Feeder protection and control
  • ACS 6000 series Medium voltage AC drives for control of 3–27 MW motors up to 3.3 kV
  • I/O Systems - S800 I/O series-ABB
  • SPAJ 140 C Series ABB
  • INCLUDING PFSK 113 7625013-S 丨ABB
  • AC 800PEC The high-performance control system for model-based design
  • HKQCS PARTS ON LINE 129740-002 ABB
  • UNITROL 6000 X-power 3BH022294R0103 GFD233A103
  • AO810 AO810V2 - ABB Ability™ System 800xA® hardware
  • Elastimold® molded vacuum reclosers – MVR MVR 0.44-10KA
  • AC 800M series PM865 3BSE030193R1 discontinued products
  • 1MRK000838-HA ABB RXIDK 2H series
  • ABB 605 series
  • Feeder protection REJ601 BD446NN1XG
  • ABB SAFT183VMC expansion module board unit specifications
  • 3BHB004661R0101 KU C711 AE; GATE UNIT POWER S GUSP
  • PRC3BSE066490R1 PM856AK01 Processor Unit
  • SM560-S (1SAP280000R0001) AC500 CPU Firmware SM560-S-FD-4
  • 769137 Detector 13CO2 10% (Uras26) ABB control unit
  • AC500 CPU Firmware
  • 0002-07-2-00001-01 BMXS Science Module (ADC)
  • Safety instructions for AC500 PLCs 3ADR025003M9903
  • ABB I/O Systems - S800 I/O AI830A
  • AC500-eCo PM556-TP-ETH; PLC-eCo CPU PM556-TP-ETH 3ABD00034186
  • ABB I/O Remote Unit ICSF08D1 CS31 CS 31 Procontic FPR3323101R1012-L
  • WMDOLT2-A75(65KA)6E 1TGE106812P0001 System circuit breaker Drawer type
  • Technical analysis of ABB 1MRK002247-Apr04 protection relay module
  • PFTL101A 0.5KN 3BSE004160R1 Pressductor PillowBlock horizontal load cell
  • 3BSE004166R1 PFTL 101A-1.0kN, Load cell
  • SD Series I/O Interface cRBX01 2VAA008424R1
  • ABB 3BSC950193R1 TB850 CEX-Bus Terminator
  • LDGRB-01 3BSE013177R1 Analysis of module technology
  • GRBTU 3BSE013175R1 Communication gateway module
  • 3BHE037864R0101P UF C911 B101: CVMI2B -PROGRAMMED-
  • Panel 800 version 6
  • 3BHE024577R0101 PPC907BE ACS 2000 Drive Manuals
  • I/O Systems - 3BSE028602R1 DO880 - ABB Ability™ System
  • ABB YPP110A 3ASD573001A1 application controller
  • 57520001-FY DSCS 150 GCOM Communication Unit
  • AC 800M - Processor Modules 3BSE018157R1 PM861AK01 Processor Unit
  • 3BSE069274R1 PP877K Key Panel 10.4" Panel 800
  • 3BSE069449R1 (CI854BK01) PROFIBUS DP-V1
  • 3BSE018135R3 CI858 ABB Ability System 800xA
  • P3BSE042238R1 PANEL 800-PP846 PRE-OWNED
  • ABB NDBU-95 NDBU - DDCS branching unit
  • X10-14210201 605-A53842-002 Abaco Systems specification
  • HIMax®System Bus Module X-SB01 Manual
  • GE Intelligent PlatformsVersaMax* PLC User Manual 151X1235DB15SA03
  • MOTOROLA FLN3524/FCN6650 adapter power supply
  • SYMAP ECG Ship Monitoring And Control Panel 12-36V DC
  • 9200 and 74712 Seismoprobe Velocity Transducers
  • 3500/91 EGD Communication Gateway Module 161204-01
  • 1900/55 Fan Monitor: Operation Manual
  • 3701/55 ADAPT (ESD) Emergency Shutdown Device 323174-01
  • 3300 XL 8 mmProximity Transducer System 330104-00-05-10-02-CN
  • MR series (Melody rack) input and output›CAC 10-P 3BDH000610R1
  • 57160001-ADF DSDP 170 inc. Pos. and Speed meas.
  • S100 I/O - Modules DSDO 115K12 Digital Outp, 32 ch, 24
  • AC 400 Power SA168K16 Basic Power Supply and Switch
  • 3BSE018290R1 DSAI 133A Analog Input Board 32 Channels
  • 3BSE011180R1 Advant Controller 450 Version 2.3 PM511V08 Processor Module
  • 3BSC950164R30 S100 I/O Cables DSTK 221L3 Cable Assembly ,Ribbon Cable,
  • 3BSE020419R1 S100 I/O - Modules DSAO 120AK01 Analog Output 8 ch 12 Bit,
  • REF3BSE012545R1 CI546 VIP Communication Interface
  • 3BSE004772R1 Advant Controller 410 Version 1.5 Communication Modules
  • AC 400 - Communication Modules 3BSE018283R1 CI522A
  • Bently Nevada 3500/05-01-03-00-00-00 Rack Module
  • 3500 Series Status System Bently Nevada 135473-01 Vibration Monitoring Module
  • 330130-045-00-00 Bently Nevada 3300 XL Extension Cable
  • Bently Nevada 330100-90-01 3300 XL 8 mmProximity Transducer System
  • Bently Nevada 149369-01 Key components of 3500 mechanical protection system
  • 106M1081-01 Universal AC Power Input Module Description
  • PR6423 8mm Eddy Current Sensor
  • PR6424 16mm Eddy Current Sensor
  • VIBRO-METER 200-560-000-112 Communication board
  • VIBRO-METER 200-510-111-035 Mechanical protection card
  • Bently Nevada 22810-01-05-50-02 Stop production status confirmation
  • 330180-91-05 Bently Nevada 5/8 mm Proximitor Sensor
  • HIEE300690R0001 AR C093 AE01 Relay Output Card
  • Multilin UR Family Proven, State-of-the-Art Protection & Control Systems
  • Multilin 8 Series Innovative protection and control relay platform
  • Multilin 3 Series Intuitive industrial and utility protective relays for feeders, motors and transformers
  • MVME177P TM Single-Board Computer MOTOROLA
  • ABB DRIVE SERVICES Spare Parts Service product description
  • Cradlepoint IBR200 Product life cycle announcement
  • CC PUIO3 series Honeywell CC-PAOH01 analog output module
  • Honeywell TC-OAV081 Analog output module p/n 97062778
  • Honeywell TC-PRR021 Redundant module DHL, UPS fast delivery
  • Honeywell TC-FXX102 TC-FX10210 controller
  • Honeywell TK-PRS021 C200 Product overview
  • Honeywell ML6420A3007-E master controller
  • Parts on HONEYWELL automaton S4560M S4560M1036 boiler-Diesel boiler
  • Honeywell PK 81181 Installation Instructions for the
  • Honeywell 2MLR-CPUH/F-CC MasterLogic-200 Specifications and Technical Data
  • 3BSE018161R1 PM864AK01 Processor Unit ABB
  • ABB 3BHE017628R0102 PPD115A102 club.
  • FANUC WHEDCO 78004655 System controller module
  • FANUC WHEDCO 78004661 Analysis I/O module