KONG -Y
NameDescriptionContent
Location:
product
HIRSCHMANN MM20-Z6T1T1T1EBH  Fast Ethernet media card.
❤ Add to collection

HIRSCHMANN MM20-Z6T1T1T1EBH Fast Ethernet media card.

HIRSCHMANN MM20-Z6T1T1T1EBH  Fast Ethernet media card.

U.S.$21400.00
U.S.$15190.00
U.S.$14430.50
U.S.$14126.70
Weight:1.290KG
Quantity:
(Inventory: 2)
Buy now
Add to cart
Description

HIRSCHMANN MM20-Z6T1T1T1EBH  Fast Ethernet media card.


Here is a technical overview for the HIRSCHMANN MM20-Z6T1T1T1EBH modular Fast Ethernet media card.

Unlike the previously discussed standard-temperature unit (SAHH), this specific model features Hirschmann's EBH environmental hardening specification, combining an extended operating temperature range with conformal PCB coating for protection against harsh chemical and outdoor conditions.

Product Introduction / Overview

The HIRSCHMANN MM20-Z6T1T1T1EBH is an industrial-grade, 4-port Fast Ethernet media module designed for Belden Hirschmann MICE (MS20/MS30 series) modular Ethernet switches.

It features a hybrid port layout—1 x Fast Ethernet SFP slot (Z6) and 3 x 10/100Base-TX RJ45 copper ports (T1T1T1).

 Engineered for high-reliability environments, the EBH tier adds conformal PCB coating (to resist conductive dust, corrosive vapors, and high humidity) and an extended temperature range ($-40^circtext{C}$ to $+70^circtext{C}$).

Technical Table

AttributeSpecification
ManufacturerBelden / Hirschmann
Product LineMICE Series Media Modules (MS20/MS30 compatible)
Part / Model NumberMM20-Z6T1T1T1EBH (Config code: MM20-Z6T1T1T1EBHH)
Port Configuration

• 1 x Fast Ethernet SFP Slot (100 Mbps)


• 3 x RJ45 Ports (10/100Base-TX)

Copper Port FunctionAuto-Negotiation, Auto-MDI/MDI-X (Auto-Crossover)
SFP Slot FunctionAccepts Hirschmann M-FAST SFP transceivers
Board ProtectionConformal Coated (Protective resin coating over PCBs)
Backplane SupportHot-swappable live insertion/removal
Ingress RatingIP20
Power ConsumptionApprox. $2.3text{ W}$ (supplied via switch backplane)

Environmental Tolerance Conditions

Operating Temperature: $-40^circtext{C}$ to $+70^circtext{C}$ (Extended Range)

Relative Humidity: 10% to 95% (non-condensing)

PCB Protection: Conformal coating against moisture, salt spray, conductive dust, and corrosive airborne contaminants.

Vibration Resistance: Tested per IEC 60068-2-6 ($1text{g}$, 10 Hz–150 Hz)

Shock Resistance: Tested per IEC 60068-2-27 ($15text{g}$ shock, 11 ms duration)

Operating Instructions

Hot-Swap Insertion: Locate an open bay on the MS20 or MS30 switch. Slide the card along the guide rails into the backplane until firmly seated.

Mechanical Fastening: Tighten top and bottom captive thumbscrews on the faceplate to ground the module body to the switch chassis.

SFP & Copper Connection: Insert the M-FAST SFP transceiver into the Z6 port until locked, then attach optical cables. Insert RJ45 Cat5e/Cat6 STP cables into the T1 ports until the tab clicks.

Unused Port Protection: Keep rubber protective plugs over unpopulated SFP slots and RJ45 jacks to avoid dust accumulation inside IP20 cabinets.

Fault Diagnosis

LED SymptomPossible CauseTroubleshooting Action
Link/Data LED OffPhysical link fail, broken cable, or unpowered remote device.Check line continuity; verify remote end is powered; check copper length ($le 100text{ m}$).
SFP Link OffUnseated SFP, dirty fiber connector, or optical wavelength mismatch.Reseat SFP module; clean fiber end-faces; confirm TX/RX fiber polarity and SFP compatibility.
Intermittent Dropped PacketsCable damaged, excessive EMI, or duplex/speed mismatch.Use shielded cables (STP); check switch management log for port speed/duplex errors.
Module UnresponsivePoor backplane connection.Loosen thumbscrews, unseat the module, and firmly re-seat it into the switch backplane.

Related Models of the Same Series

The MICE MM20/MM30 series allows mixing and matching port types and environmental tiers:

Model Part NumberPort LayoutEnvironmental / Temp Grade
MM20-Z6T1T1T1EBH (This Model)1x SFP + 3x RJ45Extended ($-40^circtext{C}text{ to }+70^circtext{C}$) + Conformal Coating
MM20-Z6T1T1T1SAHH1x SFP + 3x RJ45Standard ($0^circtext{C}text{ to }+60^circtext{C}$), Uncoated
MM20-T1T1T1T1EBH4x RJ45 CopperExtended ($-40^circtext{C}text{ to }+70^circtext{C}$) + Conformal Coating
MM20-Z6Z6EBH4x SFP SlotsExtended ($-40^circtext{C}text{ to }+70^circtext{C}$) + Conformal Coating
MM20-M4M4T1T12x Multimode SC + 2x RJ45Hybrid Fiber/Copper Module
MM22-T1T1T1T14x RJ45 CopperSupports Power over Ethernet (PoE)

Storage Conditions

Storage Temperature: $-40^circtext{C}$ to $+85^circtext{C}$ ($-40^circtext{F}$ to $+185^circtext{F}$)

Storage Relative Humidity: 5% to 95% (strictly non-condensing)

Packaging: Keep inside anti-static ESD packaging until immediate installation to protect delicate backplane connectors.


  • CTI 2500 Series® Slice Ethernet Remote I/O System
  • CTI 500 Series® Compact Programmable Automation Control System
  • CTI 2500 Series® Classic Programmable Automation Control System
  • CTI 2500 Series® Bases
  • SHINKAWA VM-25 Condition Monitoring System UPDATED
  • SHINKAWA VM-5 SERIES OPTIONS
  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 XMx16 + XIO16T extended condition monitoring modules
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK cPCI-8168 Advanced 6U CompactPCI 8-axis Motion Controller with One HSL Network
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Centralized Motion Controllers PCI-8254/8258
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3o
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET