Schneider GUTOR OC0908 Battery Voltage Detection Board
Schneider GUTOR OC0908 Battery Voltage Detection Board
The Schneider Electric GUTOR OC0908 (also cataloged as 0C0908) is a heavy-duty, high-precision telemetry card designed for real-time monitoring of DC storage arrays.
Operating as a critical component within the monitoring architecture of Gutor PEW, PDW, and SDC industrial UPS systems and rectifiers, its primary role is to execute high-accuracy voltage sampling across battery strings.
It directly enables advanced battery management functions, cell asymmetry detection, and automated capacity testing in mission-critical power networks.
Technical Parameter Table
| Parameter | Specification / Data |
| Manufacturer | Schneider Electric (Gutor Electronic LLC) |
| Model / Part Number | OC0908 / 0C0908 / GUTOROC0908 |
| Component Type | Battery Voltage Detection & Asymmetry Supervision Board |
| Host System Compatibility | Gutor PEW (AC UPS), PDW (Three-Phase UPS), SDC (DC Rectifier) |
| Monitored Battery Types | VRLA, Flooded Lead-Acid, Nickel-Cadmium (NiCad), Lithium-ion |
| Voltage Sampling Range | Supports standard industrial nominal DC links (24V, 48V, 110V, 125V, 220V, to 400VDC) |
| Measurement Resolution | Highly precise analog-to-digital (A/D) tracking down to millivolt thresholds |
| Isolation Barrier | Galvanic isolation up to 2.5 kV to isolate high DC potentials from logic rails |
| Communications Bus | Inter-board synchronous bus linking directly to the main processor board |
| Protective Coating | Industrial conformal coating against humidity, acid mist, and particulates |
| Operating Temperature | -10°C to +55°C (+14°F to +131°F) |
Related Models & Product Ecosystem
The OC0908 functions in close coordination with central control logic and environmental sensors across the Gutor hardware ecosystem:
Gutor G.BMS (Battery Management System Modules): Works alongside decentralized cell-level balancing blocks.
Gutor OP0326 / OP0363: Central controller and signals processor boards that ingest raw data from the OC0908.
Gutor Temperature Sensors (Ambient/Battery): Paired with the OC0908 to allow the charger to execute temperature-compensated float and boost charging profiles.
Gutor External Connection Boards: Routes physical tap wires from the external battery circuit breaker box (MCCB) to the sampling inputs.
Product Advantages and Features
Advanced Battery Asymmetry Detection: Continuously compares intermediate center-tap voltages against total string voltage. It triggers instant alarms if cell imbalance, sulfation, or a short-circuited cell is detected before total string failure occurs.
High Galvanic Isolation Safety: Protects the sensitive microprocessor logic of the main UPS card rack from high-energy DC bus faults, transient ground loops, or battery short circuits.
Facilitates Safe Capacity Tests: Serves as the primary feedback loop during programmable battery discharge and monitor testing, tracking real-time curve degradation without dropping the critical plant load.
Corrosion-Resistant Industrial Design: Built to tolerate battery room environments where trace chemical outgassing, high humidity, and wide ambient temperature swings can quickly degrade standard PCBs.
Application Cases
Oil & Gas Offshore Platforms: Installed inside Gutor PEW units to provide remote operators with exact battery backup time remaining metrics under high-vibration and corrosive salt-air conditions.
Nuclear Power Plant (NPP) Safety Systems: Deployed in hardware compliant with IEC 60888 nuclear lifecycle standards, where battery tracking must execute with independent, fail-safe redundancy.
Chemical Processing Substations: Utilized in harsh electrical environments to interface large-scale NiCad battery banks directly into centralized SCADA and Schneider EcoStruxure automation networks.
Other Models in the Same Series
Depending on system scale, string topology, or generation differences within Gutor control enclosures, adjacent modules include:
Gutor 0400649: Multi-channel system signaling and telemetry board.
Gutor OC0947: IGBT and heat sink temperature measurement sampling board.
Gutor Type A/B Analog Interface Boards: Legacy voltage/current monitoring loops.
Installation and Maintenance
Installation Guidelines:
Isolate DC Potential Safely: Open the battery circuit breaker (MCCB) or pull the string fuses. Ensure zero voltage exists on the sensing lines running into the UPS control enclosure before handling.
Electrostatic Discharge (ESD) Measures: Wear an approved ESD grounding wrist strap. Handle the OC0908 card exclusively by its non-conductive edges or faceplate.
Sensing Terminal Interconnection: Ensure tap cables from the midpoints and terminals of the battery strings are securely landed on the input terminals with correct polarity. Tighten screws to prevent signal floating or resistance errors.
Maintenance & Troubleshooting:
Calibration Verification: During major multi-year service checks, cross-verify the voltage reading reported on the Gutor HMI against a calibrated handheld digital multimeter directly at the OC0908 test
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
Add: High-tech Software Park, Xiamen City, Fujian Province
Mobile: +86-17750019513(WhatsApp)
Email: yy4291644@gmail.com
Website: https://www.abb-sis.com