KONG -Y
NameDescriptionContent
Location:
product
LAUER  PCS 9000 / PCS 910  HMI
❤ Add to collection

LAUER PCS 9000 / PCS 910 HMI

LAUER PCS9100: Leading the Way in Automation Solutions
U.S.$18038.00
U.S.$17110.00
U.S.$16254.50
U.S.$15912.30
Weight:4.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
LAUER PCS9100: Leading the Way in Automation Solutions

The electrial connection between an arbritrary programming controller and a PCS is made via a matching adapter cable PCS. Data communication is based on an intelligible principle: The PCS writes functions or preset values into predefined word areas of the programmable controller. The programmable controller then reads these words and interpretes them. The programmable controller writes  functions or actual values into predefined word areas. The PCS automatically reads and interpretes those word contents. Depending on the type of the program mable controller, a maximum of 256 words with 16 bits each are available resulting in 4096 I/O points for PCS/ programmable controller communica tion. The data words DW 00 ... DW 24 are reserved for the PCSmaxi  (please refer to page 16 ... 22). The data words 25 up to 255 are available for any operating application. The assignment of these data words is free.

For the communication of the PCSmaxi with an arbritrary programmable controller, data words (flags or simular) are used. A defined task or function is assigned to each data word DW: Data word ERROR WORD DW 03 KEY WORDS: DW 04 DW 05 DW 06 DW 07 Function Error word/synchronizing word - driver specific (please refer to the driver manual PCS 91.xxx) Function keys F1...F16 Vertical soft-keys T1...T10 (PCS 9100 only) Control and cursor keys Numeric keypad, DIL switch PCS STATUS WORDS: DW 08 Priority state The currently highest priority is stored in bits 15...8. Bit 15...8 = 28 Bit 15...8 Bit 15...8 Bit 15...8 Bit 15...8 Bit 15...8 = 24 = 20 = 16 = 12 = 0 Recipe (highest priority) Menu Fault Warning Info Idle page (lowest priority) The currently active priorities are stored in bits 7...0. Bit 3 Fault Bit 2 Bit 1 Bit 0 DW 09 Warning Info Menu Page number with focus The page number with the highest priority is stored: PCS Prog. contr. Data direction 

 • with help active the number of the help page (HLP_PAGE) 

 • with recipe active the number of the recipe page 

 • with a menu active the number of the operating page (OP_PAGE) 

 • with messages active the number of the message page (MSG_PAGE) 

 • otherwise the number of the idle page (REPORT_PAGE)

Data word DW 10 DW 11 DW 12 Function Number of the menu node Basically, 0 is returned for menus with only 1 node PCS Prog. contr. Data direction Preset value word number, length of the preset value Bits 15...8 Bit 7...0 DW Number of the last modified preset value Length in bytes of the last modified preset value. If the bits 7...0 = 0, it is a BIT or GBIT variable Bit mask of the last modified BIT/GBIT variable DW 12 is only valid, if in DW 11 the bits 7...0 = 0 COMMAND WORDS: DW 13 values. Transfer locking Locking the transfer reduces the response time of further transmitted Bit 4 Bit 1 Bit 0 Bit X 1 if no LEDs should be transmitted 1 if no messages should be transmitted 1 if no menus should be transmitted 1 if no date information should be transmitted. The X position (0...15) is defined by the internal variable [CLK_DBIT] which can be specified optionally. Locking of the transfer is not possible, if the internal variable is not parameterized. Bit X 1 if no time information should be transmitted. The X position (0...15) is defined by the internal variable [CLK_CBIT] which can be specified optionally. Locking of the transfer is not possible, if the internal variable is not parameterized. Bit X 1 if no operating printer pages should be transmitted. The X position (0...15) is defined by the internal variable [OPPRT_SBIT] which can be specified optionally. Locking of the transfer is not possible, if the internal variable is not parameterized.

Data word DW 14 DW 15 Function Display locking Bit 5 Bit 4 1 if no status page should be displayed PCS Prog. contr. Data direction 1 if no soft-key labeling should be displayed Bit 3 Bit 2 Bit 1 Bit 0 1 if no faults should be displayed 1 if no warnings should be displayed 1 if no infos should be displayed 1 if no menus should be displayed Activating bits Bit 10 if set to 1, counter ZR2 is set to 0 Bit 9 if set to 1, counter ZR1 is set to 0 Bit 8 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 if set to 1, counter ZR0 is set to 0 set to 1 to activate the elasped-hour meter set to 1 to enable the alarm output if set to 1, positive pulses are counted at input ZR2 if set to 0, counting is interrupted if set to 1, positive pulses are counted at input ZR1 if set to 0, counting is interrupted if set to 1, positive pulses are counted at input ZR0 if set to 0, counting is interrupted

  • ADLINK cPCI-8168 Advanced 6U CompactPCI 8-axis Motion Controller with One HSL Network
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Centralized Motion Controllers PCI-8254/8258
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3o
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output