ABB REF630 UBFNAAABBBAZANBBXB Feeder Protection and Device
ABB REF630 UBFNAAABBBAZANBBXB Feeder Protection and Device
Overview
REM630 is a comprehensive motor management relay for protection, control,
measuring and supervision of medium and large synchronous and asynchronous
motors in medium voltage industrial power systems. REM630 is a member of ABB’s
Relion® product family and a part of its 630 series characterized by functional
scalability and flexible configurability. REM630 also features necessary control
functions required for the management of industrial motor feeder bays. The protection
relay can be used with both circuit-breaker controlled and contactor controlled drives.
The supported communication protocols including IEC 61850 offer seamless
connectivity to industrial automation systems.
Product version history
Product version
Product history
First release
• Support for IEC 60870-5-103 communication protocol
• Analog GOOSE
• RTD module
• New analog input modules
• Stabilized three-phase differential protection for motors and generators
• High-impedance/flux-balance-based differential protection for motors
and generators
• Synchronized motor protections
No new functions
• Operation time counter
• Comparison functions
• AND and OR gates with 20 inputs
PCM600 and IED connectivity package version
• Protection and Control IED Manager PCM600 Ver. 2.5 or later
• ABB REM630 Connectivity Package Ver. 1.3 or later
• Application Configuration
• Parameter Setting
• Signal Matrix
• Signal Monitoring
• Disturbance Handling
• Event Viewer
• Graphical Display Editor
Hardware Configuration
• IED Users
• IED Compare
• Communication Management
• Configuration Migratio
Product variants
The IED capabilities can be adjusted by selecting a product variant. The IED
capabilities can be extended by adding HW and/or SW options to the basic variant. For
example, the physical communication connector can be either an electrical or optical
Ethernet connector.
The number of binary inputs and outputs depends on the amount of the optional BIO
modules selected. For a 4U IED, it is possible to take 2 additional BIO modules at the
maximum, and for a 6U IED, it is possible to take 4 additional BIO modules at the
maximum.
• Basic variant: 14 binary inputs and 9 binary outputs
• With one optional BIO module: 23 binary inputs and 18 binary outputs
• With two optional BIO modules: 32 binary inputs and 27 binary outputs
• With three optional BIO modules: 41 binary inputs and 36 binary outputs
• With four optional BIO modules: 50 binary inputs and 45 binary outputs
Optional functions
Some of the available functions are optional, that is, they are included in the delivered
product only when defined by the order code.
• Frequency protection
• Overfrequency protection
• Underfrequency protection
• Frequency gradient
• Phase sequence voltage functions
Positive-sequence overvoltage protection
• Positive-sequence undervoltage protection
• Negative-sequence overvoltage protection
• Stabilized differential protection for motors
• Additional functions for synchronous motor
• Reverse power/directional overpower protection
• Three-phase underexcitation protection
• Rotor E/F protection
Physical hardware
The mechanical design of the IED is based on a robust mechanical rack. The HW
design is based on the possibility to adapt the HW module configuration to different
customer applications.
Table 2:
IED contents
Content options
LHMI
Communication and
CPU module
Auxiliary power/binary
output module
1 electrical Ethernet connector for the detached LHMI module (the connector
must not be used for any other purpose)
1 Ethernet connector for communication (selectable electrical or optical
connector)
IRIG-B (external time synchronization) connector
1 fibre-optic connector pair for serial communication (selectable plastic or
glass fibre)
14 binary control inputs
48-125 V DC or 100-240 V AC/110-250 V DC
Input contacts for the supervision of the auxiliary supply battery level
3 normally open power output contacts with TCS
3 normally open power output contacts
1 change-over signalling contact
3 additional signalling contacts
1 dedicated internal fault output contact
Analog input module
4. 7 or 8 current inputs (1/5 A)
4. 3 or 2 voltage inputs (100/110/115/120 V)
With 4 current inputs (1/5 A) also max. 1 accurate current input for sensitive
earth fault protection (0.1/0.5 A)
| ABB | 07BR61R1 GJV3074376R1 |
| ABB | 6231BP10910 |
| ABB | TU847 3BSE022462R1 |
| ABB | 5SHY35L4520 5SXE10-0181 AC10272001R0101 |
| ABB | PM825 3BSE010796R1 |
| ABB | PFEA112-20 3BSE030369R0020 |
| ABB | CI858-1 3BSE018137R1 |
| ABB | PFTL201C 10KN 3BSE007913R0010 |
| ABB | DSAI133A 3BSE018290R1 |
| ABB | DSAI133A 3BSE018290R1 |
| ABB | PFSK142 3BSE006505R1 |
| ABB | 216DB61 HESG324063R100/J |
| ABB | 216EA62 1MRB150083R1/F 1MRB178066R1/F |
| ABB | UNS4881b,V4 3BHE009949R0004 |
| ABB | UNS2882A 3BHE003855R0001 |
| ABB | UNS0887A-P 3BHE008128R0001 |
| ABB | UNS2880b-P,V2 3BHE014967R0002 |
| ABB | UNS2881b-P,V1 3BHE009319R0001 |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
Add: High-tech Software Park, Xiamen City, Fujian Province
Mobile: +86-17750019513(WhatsApp)
Email: yy4291644@gmail.com