THQD22150WL GE Molded Case Circuit Breaker
Product Description P/N: THQD22150WL DESCRIPTION / SPECIFICATIONS Description THQD22150WL - General Electric THQD series double pole single phase 150 ampere feed-thru molded case circuit breaker with maximum voltage rating of 240V. Trip type is fixed thermal magnetic common trip. Standard interrupting rating is 22 kiloampere at 240V. Includes non-interchangeable trip unit and line & load side lug terminals. Technical Specifications Part Number THQD22150WL Manufacturer General Electric Family Q-Line Pole 2 Amp 150 Volt 240 Phase 1 Category Molded Case / 2-Pole Connection Feed-Thru Type THQD Functions LI - Long-Time and Instantaneous Protection Thermal Magnetic AIC Ratings 22kA@240V Information About THQD22150WL The THQD22150WL from General Electric belongs to the Q-Line series of molded case circuit breakers. It is a double-pole, single-phase unit designed for feed-thru applications, rated at 150 amperes with a maximum voltage capacity of 240V. The circuit breaker features a fixed thermal magnetic trip type with a common trip mechanism. It adheres to standard interrupting ratings of 22 kiloamperes at 240V. This model is equipped with a non-interchangeable trip unit, ensuring consistent performance and reliability in interrupting current during overloads and short circuits. The line and load sides of the breaker are fitted with lug terminals, facilitating secure electrical connections within the circuit. Designed for robust industrial applications, the THQD22150WL ensures effective protection against overcurrent events with its thermal magnetic mechanism. It operates within a broad temperature range suitable for various environmental conditions typically found in industrial settings. Manufacturer information General Electric (GE) is a multinational conglomerate founded in 1892, based in the United States. It operates in various industries, including aviation, healthcare, renewable energy, and power.
You can eliminate unnecessary exchanges for a module type by removing the allocation of the time slot to that TVA. For example, for performance reasons, validator TVAs for that module type could be eliminated. (You cannot eliminate exchanges for an entire module type). If you edit exchange definitions for remote racks, the changes will take effect when a remote I/O rack connects to the network segment or when an I/O module is inserted. Changed exchange definitions do not affect devices already in place. For remote I/O racks (and Field Control I/O Stations), the I/O Racks tab has three tabs: System TVAs Input Modules Output Modules
Inventory-related model
IS230TNPAH2A
F650BABF2G0LOSHE
IS220PAICH1A
DS215TCQAG1BZZ01A
IS215UCVEH2AE
IS200SDIIH1ADB MRP683026
IS200TREGH1BDB
IS220PDOAH1B
IS220PAICH1A
IC697CPM925
IS200TREAH2AED
UR6DH
HR911103A VMIVME-7750的RJ45
User name | Member Level | Quantity | Specification | Purchase Date |
---|
Add: Building F05, High-tech Software Park, Xiamen City, Fujian Province
Tel: 0592-5211302
Mobile: 17750019513 (WhatsApp)
Email: yy4291644@gmail.com
ivy@kongjiangauto.com
Website: https://www.abb-sis.com