KONG -Y
NameDescriptionContent
Location:
product
UNITROL 1010 3BHE035301R1002 UNS 0121A-Z,V1 UN1010-0001 ABBcontrol unit
❤ Add to collection

UNITROL 1010 3BHE035301R1002 UNS 0121A-Z,V1 UN1010-0001 ABBcontrol unit

UNITROL1010-3BHE035301R1002-UNS0121A-Z-V1-UN1010-0001

U.S.$5920.00
U.S.$86300.00
U.S.$81985.00
U.S.$80259.00
Weight:1.190KG
Quantity:
(Inventory: 99999)
Buy now
Add to cart
Description

UNITROL1010-3BHE035301R1002-UNS0121A-Z-V1-UN1010-0001


UNITROL 1010 3BHE035301R1002 UNS 0121A-Z,V1 UN1010-0001 ABBcontrol unit

Obey these safety precautions before you do work on the system: 

  1. Clearly identify the work location and equipment.

  2. 2. Disconnect all possible voltage sources. Make sure that reconnection is not possible. Lock out and tag out.

  3. • Open the main disconnecting device of the AVR.

  4. • Disconnect any external power sources from the control circuits before you do work on the control cables.

  5. • If you have a permanent magnet generator connected to the AVR, disconnect it from the AVR with a safety switch or by other means.

  6. • After you disconnect the AVR, always wait for 5 minutes to let the intermediate circuit capacitors discharge before you continue.

  7. • Do not do work on the AVR when the amber warning LED flashes. 3. Protect any other energized parts in the work location against contact. 4. Take special precautions when you are near bare conductors. 5. Measure that the installation is de-energized.

  8. • Use a multimeter with an impedance of at least 1 Mohm.

  9. • Make sure that the voltage between the AVR input power terminals (PWR L1, PWR L2 and PWR L3) and the grounding terminal (PE) is near 0 V.

  10. • Make sure that the voltage between the AVR output terminals (IE+, IEand ExCap) and the grounding terminal (PE) is close to 0 V. 6. Install temporary grounding as required by the local regulations. 7. Ask for a permit to work from the person in control of the electrical installation work.  Residual danger areas WARNING! Do not do work on the AVR when the amber warning LED flashes. When the AVR operates,

  11. • The voltage in the power section can be up to 300 V AC and the short-circuit current is very high.

  12. • The voltage in the control cabinet is more than 50 V. When the AVR is disconnected from power supplies, the large capacitors in the AVR hold a charge for some time. Wait for at least 5 minutes for the capacitors to discharge before you do work on the AVR. An amber warning LED flashes if the internal voltage is more than 30 V DC. Warning labels are attached to all of the cubicle doors to warn personnel against opening the doors during operation. If the device is built into a larger system, additional warning labels are attached to the inside of the cubicle doors and to the covers of the power converter modules. Consider the residual danger areas when you do work on the excitation system:

  13. • Danger from live equipment inside the excitation system, if the protective covers are removed.

  14. • Hazardous voltages from the rotor field winding and the secondary side of the excitation transformer.

  15. • Danger from charged capacitors if a cabinet door is open immediately after the system stops.

  16. • Danger from main and auxiliary voltages when cubicle doors are open. Introduction This document is a quick installation guide for the UNITROL 1010 and UNITROL 1020 automatic voltage regulator. Make sure that you read and understand this document before you install or use the product. This document is meant only as a brief guide to the product. For detailed information on the product, refer to the User Manual. Device description UNITROL 1010 and UNITROL 1020 are automatic voltage regulators (AVR) for synchronous machines of up to 80 MVA. The AVRs can be used for the excitation of indirectly excited synchronous machines and motors. The AVRs can also operate as a reactive power regulators, power factor regulators or field current regulators. Product package Contents of the product package:

  17. • UNITROL 1000 series AVR

  18. • Special red USB cable that is used to power and to connect with the AVR. Keep this USB cable in a safe place.

  19. • Red jumper blocks (3 pcs.)

  20. • Quick installation guide and test certificate Make sure that all of the listed items are in the product package and that there is no damage to the items. Hardware overview Primary parts of the AVR. Refer to the User Manual for more information.  Warning and status indicators Mechanical installation For detailed information on mechanical installation, refer to the User Manual. Install the AVR in an indoor area that is dry and dust-free, and that does not contain volatile gases, acid fumes or similar hazards. Examine the installation area and refer to technical data to make sure that:

  21. • The maximum ambient temperature is in the permitted range.

  22. • The vibration is limited and within the permitted class.

  23. • The ingress protection and pollution degree are suitable.

  24. • The EMC environment is suitable. Installation requirements:

  25. • Install the AVR vertically to make sure that cooling operates correctly.

  26. • Free space requirements:

  27. • 50 mm above the AVR

  28. • 20 mm below the AVR

  29. • 10 mm on the left and right sides of the AVR

  30. • Make sure that there is sufficient cooling air flow around the AVR.

  31. • Make sure that other devices do not blow hot air on to the AVR.

  32. • The AVR is designed to be installed with suitable hardware to an installation plate.

  33. • Make sure that the frame of the AVR is electrically grounded (PE) to the installation plate with a grounding wire (≥4 mm2) through a mounting hole. Use toothed washers to get a good electrical ground contact. Installation procedure: 1. Refer to Dimensions for the mounting hole dimensions. 2. Make the appropriate holes in the installation plate. 3. Attach the AVR to the installation plate with suitable hardware, for example, M6 screws to a torque of 10 Nm. The mounting holes have a diameter of 6.5 mm. 4. Make sure that there is a good electrical ground connection between the installation plate and the AVR.

  34. The installation plate must be electrically grounded (PE). Electrical installation For detailed information on electrical installation, refer to the User Manual. CAUTION! Separate control (I/O) cables from the excitation (power and measurement) cables to avoid electromagnetic interference. Cable dimension requirements: Grounding Connect the AVR to the protective earth at terminal 17 with a 4 mm2 grounding wire. Make an additional grounding connection through the mounting holes to the installation plate (if it is connected to the protective earth) or with a 4 mm2 cable to the protective earth. Make sure that the grounding connections are as short as possible. Additional signal ground terminals are provided for the control cables. Inrush current limitation The large internal DC capacitor of the AVR can cause a high inrush current especially with a strong voltage source. WARNING! To prevent damage to the AVR, make sure that the inrush current is not more than 200 A for 10 ms. To prevent damage to the AVR from a high inrush current: To calculate the inrush current, you can use a capacitor voltage of 0 V at startup.

  35. The external resistor for a 200 V AC input is typically 1.5 Ω. Power and measurement terminals 1) To reduce wiring, you can connect each phase of the excitation power inputs (PWR) and auxiliary power supply inputs (AUX) with the included jumpers. Commissioning For detailed instructions on commissioning, refer to the User Manual. Commissioning procedure overview: 1. Make sure that all of the connections are correct and safe. 2. Download the configuration file to the AVR. Make sure that the parameters are correct. 3. Examine the digital and analog I/Os in standstill. 4. Do tests with the machine: a) Standstill

  36. • Measure resistance of exciter stator winding. b) No load condition

  37. • Increase the speed of the machine to nominal.

  38. • Start excitation in Manual mode and increase the manual setpoint until machine voltage is 50%.

  39. • Use CMT 1000 to verify the AVR measurements and compare them with other equipment used, such as protection devices.

  40. • Increase the setpoint until the machine voltage is 100% and tune the AVR with the AVR tuning assistant.

  41. • Do step response tests to examine performance in Manual mode and Auto mode. c) Machine connected to grid

  42. • Select AUTO (voltage regulator).

  43. • Increase the AUTO setpoint to verify the polarity of the of IM measurement. Q must increase. d) Do step response tests to examine performance in Auto mode and direct VAR regulator modes. 5. Finalizing commissioning a) Save the parameters on the AVR and verify the status with CMT 1000. b) Save backup files for project documentation.


  • VIBRO-METER VM600Mk2/ VM600 XMx16 + XIO16T extended condition monitoring modules
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK cPCI-8168 Advanced 6U CompactPCI 8-axis Motion Controller with One HSL Network
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Centralized Motion Controllers PCI-8254/8258
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3o
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®