SHINKAWA MODEL VM-5C ECCENTRICITY MONITOR
MODEL VM-5C ECCENTRICITY MONITOR
onitor range
pk-pk
Monitor range
direct
Input signal
(Rotor pulse:CH1)
Input signal
(Ecc:CH2)
Direct
Eccentricity
polarity
*2
Measurement range
*3 Recorder
output
1 0 to 100 m pk-pk -50 to 0 to +50 m 1 VK-202A,VK-202P *1 1 VK-202A,VK-202P,FK-202F 1 Direct 1 1 to approx.300rpm 0 4 to 20mADC
2 0 to 200 m pk-pk -100 to 0 to +100 m 2 RD,FK Series 2 VK-302P,FK-302F 2 Reverse 2 1 to approx.600rpm 1 1 to 5VDC
3 0 to 250 m pk-pk -125 to 0 to +125 m 3 MS Series
4 or more pulses per
revolution with even duty
3 VK-452A,FK-452F
2
Output card
/IS or /RE
option
4 0 to 500 m pk-pk -250 to 0 to +250 m 4 VK-602P,FK-602F
5 0 to 1000 m pk-pk -500 to 0 to +500 m 5 VC Series(Voltage output only)
6 0 to 5mils pk-pk -2.5 to 0 to +2.5mils
7 0 to 10mils pk-pk -5 to 0 to +5mils
8 0 to 20mils pk-pk -10 to 0 to +10mils
A 0 to 30mils pk-pk -15 to 0 to +15mils
B 0 to 50mils pk-pk -25 to 0 to +25mils
Hysteresis set value
(shaped waveform circuit)
Alarm reset
(DANGER)
Alarm reset
(ALERT)
Alarm reset
(OK)
Relay mode
(DANGER)
Relay mode
(ALERT)
Relay mode
(OK)
First out
*4
Phase marker
input
0 1.0V 0 AUTO-RESET 0 AUTO-RESET 0 AUTO-RESET 0 NORMALLY
DE-ENERGIZED
0 NORMALLY
DE-ENERGIZED
0 NORMALLY
DE-ENERGIZED
0 OFF 0 CH1(VM-5C)
1 0.1V 1 SELF-HOLD 1 SELF-HOLD 1 SELF-HOLD 1 ON 1 CH1(VM-5P)
2 0.2V 1 NORMALLY
ENERGIZED
1 NORMALLY
ENERGIZED
1 NORMALLY
ENERGIZED
3 0.5V
Isolate output Recorder option
output
Input power supply
requirements*5
Tropical
spec.
Sensitivity
correction
0 4 to 20mADC 2 0 to -10VDC 0 85 to 264VAC 1 TIIS(IEC)
1 1 to 5VDC 3 0 to 10VDC 1 24VDC 2 FM
2 0 to -10VDC 4 0 to -5VDC 2 110VDC 4 CSA
3 0 to 10VDC 5 0 to 5VDC 5 ATEX
4 0 to -5VDC
5 0 to 5VDC
Ordering Information Standard Specifications
ALARM SET VALUE DANGER1 :
ALERT1 :
H-DANGER2 :
H-ALERT2 :
L-ALERT2 :
L-DANGER2 :
DANGER1,ALERT1 : For eccentricity pk-pk
DANGER2,ALERT2 : For direct
Unless specified otherwise, preset to :
DANGER1 : 100% of monitor range
ALERT1 : 90% of monitor range
H-DANGER2 : Invalid
H-ALERT2 : Invalid
L-ALERT2 : Invalid
L-DANGER2 : Invalid
MEASURED VALUE LCD digital meter with 5 digits (7 segments,with back light)
LCD bar graph meter (40 segments,with back light)
* Measurement value and alarm set value are indicated on the
digital meter and bar graph meter simultaneously.
ALAMR INDICATOR DANGER : (red LED)
ALERT : (yellow LED)
ABNOR. ALAMR
INDICATOR OK : (green LED)
BYPASS INDICATOR BYPASS : (red LED)
TRANSDUCER INPUT VK-202A,VK-202P,FK-202F,
VK-302P,FK-302F,VK-452A,FK-452F,VK-602P,FK-602F (only eccentricity),
VC Series(only eccentricity),
RD-05A(only phase marker),MS Series(only phase marker)
Number of input points : 2 points(phase marker,eccentricity)
NO. OF INPUT P/R Can be specified from 1 to 120 pulse.
Pulses/rev. :
INPUT IMPEDANCE Approx.50k
MIN. PULSE WIDTH Approx.50μsec
DIMENSION OF TARGET
(Model VK,RD,FK)
Note) To detect a projection (gear), provide surface A of the projection with a concentric curve.
Do not make it flat.
A= mm
B= mm
C= mm
D= mm
| Foxboro | FBM217 |
| Foxboro | FBM201 P0914SQ |
| Foxboro | FBM237 P0914XS |
| Foxboro | FBM203 RH914SV |
| Foxboro | FBM201TA P0916AA |
| Foxboro | FBM237TA P0916CC |
| Foxboro | FBM203TA PO916AE |
| Foxboro | P0916DE |
| ABB | 3BHE057901R0101 PCD235C101 |
| Triconex | 3704E |
| Triconex | 3504E |
| Triconex | 3504E |
| EMERSON | 1X00781H01L |
| EMERSON | PR6423 009-041+CON 041/913-030 |
| KONSGBERG | RCU500 |
NO. OF INPUT PULSE 1 to 120 pulse
TRIGGER MODE AUTO, MANUAL (selectable)
In case of auto trigger mode, input pulse duty ratio should be between
10 and 90% and input pulse frequency should be 1Hz and over.
It depends on the target.
EXTERNAL CONTACT
INPUT
(FROM REAR PANEL)
Contact type : Dry contact
Contact for external reset
BAR GRAPH METER Recorder output conversion accuracy 2.5% of F.S.
ZERO SHIFT 0 to 100% of monitor range
DIGITAL METER Recorder output conversion accuracy 1.0% of F.S.
RECORDER OUTPUT
CONVERSION
ACCURACY
1.0% of F.S. at 25°C
2.0% of F.S. at 0 to 65°C
RECORDER OUTPUT
(FROM REAR PANEL)
Voltage or current output proportional to monitor range
1 to 5VDC (output impedance : 250)
4 to 20mADC (max. load resistance : 500)
0 to -10VDC*,0 to 10VDC*,0 to -5VDC*,0 to 5VDC*
(output impedance : 100) (*option)
Number of output points : 2 points(eccentricity pk-pk,direct)
SUPPRESSION
FUNCTION SET VALUE
: 0.0 to 10.0 % of monitor range (0.1 % step)
Preset to 2.0 % unless specified otherwise.
CAUTION : When the measurement value is not more than
suppression function set value, indication and
recorder output value shall be as 0 %.
MONITOR/PULSE
OUTPUT
(FROM FRONT,REAR
PANEL)
Monitor output/Pulse output, selectable
(preset to CH1 : Pulse output, CH2 : Monitor output)
Monitor output : Input signal is output via a buffer amplifier.
Signal level : -0.8 to -22VDC (VK,RD),± 15V (MS),
0 to 5VDC(VC)
Pulse output : Shaped pulse signal is output via a buffer
amplifier.
Signal level : -1 to +1V(PL),4 to 6V(PH)
Output impedance : Approx.100 (load resistance 50k or more)
Standard Specifications
ALARM SET POINT