SHINKAWA MODEL VM-5N RAMP DIFFERENTIAL
MODEL VM-5N RAMP DIFFERENTIAL
EXPANSION MONITOR
onitor range Input signal Frequency
response Polarity*1 Operation method Recorder output Alarm reset
(DANGER)
Alarm reset
(ALERT)
Alarm reset
(OK)
1 -5 to 0 to +5mm 1 VK-143P,
FK-143F
0 DC to 0.5Hz 1 Direct 1 Differential
(both CH:same ramp angle)
0 4 to 20mADC 0 AUTO-RESET 0 AUTO-RESET 0 AUTO-RESET
2 0 to 10mm 2 Reverse 1 1 to 5VDC 1 SELF-HOLD 1 SELF-HOLD 1 SELF-HOLD
3 -10 to 0 to +10mm 2 VK-263P,
FK-263F
2 Additional
(both CH:same ramp angle) 2
Output card
/IS or /RE
option
4 0 to 20mm
5 -25 to 0 to +25mm VC Series 3 CH1:specified ramp angle
CH2:0°
6 0 to 50mm 3 Voltage
7 -0.25 to 0 to +0.25inch output
8 0 to 0.5inch only
A -0.5 to 0 to +0.5inch
B 0 to 1.0inch
C -1.0 to 0 to +1.0inch
D 0 to 2.0inch
Relay mode
(DANGER)
Relay mode
(ALERT)
Relay mode
(OK)
Alarm delay time
(DANGER)
Alarm delay time
(ALERT) Alarm output type First out*2
0 NORMALLY
DE-ENERGIZED 0 NORMALLY
DE-ENERGIZED 0 NORMALLY
DE-ENERGIZED
0 3 sec. 0 3 sec. 1 CH1 : 2 points (DANGER1,ALERT1)
H,L are OR output
0 OFF
1 1 sec. 1 1 sec. 1 ON
1 NORMALLY
ENERGIZED 1 NORMALLY
ENERGIZED 1 NORMALLY
ENERGIZED
2 6 sec. 2 6 sec. 2 CH1 : 4 points (H-DANGER,H-ALERT,
L-ALERT,L-DANGER)
3 None 3 None
Isolate output Recorder option
output
Input power supply
requirements*3
Tropical
spec.
Sensitivity
correction
0 4 to 20mADC 2 0 to -10VDC 0 85 to 264VAC 2 FM
1 1 to 5VDC 3 0 to 10VDC 1 24VDC 4 CSA
2 0 to -10VDC 4 0 to -5VDC 2 110VDC 5 ATEX
3 0 to 10VDC 5 0 to 5VDC
4 0 to -5VDC
5 0 to 5VDC
ALARM SET VALUE H-DANGER :
H-ALERT :
L-ALERT :
L-DANGER :
Unless specified otherwise, preset to :
H-DANGER : 100% of monitor range
H-ALERT : 90% of monitor range
L-ALERT : 10% of monitor range
L-DANGER : 0% of monitor range
ALARM INDICATOR DANGER : (red LED)
ALERT : (yellow LED)
ABNOR.ALARM
INDICATOR
OK : (green LED)
| ABB | REF601CE446BB1NH 24-240V 50/60Hz |
| ABB | UFC765AE102 3BHE00364R0102 |
| bently | 3500/60 |
| PROCONTROL P | GJR2395500R1210 83SR50 |
| PROCONTROL P | 5102-MCM4-DFCM4 |
| ABB | 81943A059-1 |
| ABB | 81943A059-2 |
| ABB | A419471 |
| ABB | AINT-14C |
| bently | 3500/92-02-01-01 |
| bently | 3500/32-01-01 |
| bently | 3500/33-01-01 |
| bently | 3500/25-01-01-00 |
| bently | 3500/40M-01-01 |
| bently | 3500/22M-01-02-01 |
| Meggitt | CA202 – 144-202-000-203 |
| Meggitt | TQ402 – 111-402-000-012 |
| bently | 3500/92-02-01-01 |
BYPASS INDICATOR BYPASS : (red LED)
TRANSDUCER
INTPUT
VK-143P,FK-143F,VK-263P,FK-263F,VC Serie
Number of input points : 2 points
INPUT IMPEDANCE Approx. 50kΩ
EXTERNAL CONTACT
INPUT
(FROM REAR PANEL)
Contact type : Dry contact
Contact for external reset
RAMP ANGLE Installation angle allows between 4 to 90°00’
Ramp angle :
OTHERS
BAR GRAPH METER Recorder output conversion accuracy ±2.5% of F.S.
ZERO SHIFT 0 to 100% of monitor range
DIGITAL METER Recorder output conversion accuracy ±1.0% of F.S.
RECORDER OUTPUT
(FROM REAR PANEL)
±0.5% of F.S. at 25°C
±2.0% of F.S. at 0 to 65°C
Standard Specifications
RECORDER OUTPUT
(FROM REAR PANEL)
Voltage or current output proportional to monitor range
1 to 5VDC (output impedance : 250Ω)
4 to 20mADC (max.load resistance : 500Ω)
0 to 10VDC*, 0 to 10VDC*, 0 to -5VDC*, 0 to 5VDC*
(output impedance : 100Ω) (*option)
Number of output points : 1 point
ALARM SET POINT 4 points (DANGER1, ALERT1, DANGER2, ALERT2)
ALARM SET RANGE -10 to 110% of monitor range
ALARM SET
ACCURACY
±1.0% of F.S. or less
ALARM SET
REPEATABILITY
±0.1% of F.S. or less
MONITOR OUTPUT
(FROM FRONT,REAR
PANEL)
Input signal is output via a buffer amplifier.
Signal level : -0.8 to -22VDC(VK), 0 to 5VDC(VC)
Output impedance : 100Ω (load resistance 50k or more) ALARM OUTPUT 3 points (DANGER, ALERT, OK) or
4 opints (DANGER, ALERT, OK1, OK2) (H, L are OR output)
(6 points when 4-point alarm is selected for CH1)
TEMPERATURE
RANGE
Operating temperature : 0 to 65°C(32 to 149°F)
Storage temperature : -30 to +85°C (-22 to +185°F)
Relative humidity : 20 to 95%RH(noncondensing) MEASURED VALUE LCD digital meter with 5 digits (7 segments, with back light)
LCD bar graph meter (40 segments, with back light)
* Measurement value and alarm set value are indicated
on the digital meter and bar graph meter
simultaneously.
MATERIAL AND
FINISH
Face plate : Aluminum Munsell N-4.0 (equiv.)
MASS Monitor : max.0.7kg
(including single unit instrument rack : max.2.5kg)
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
Add: High-tech Software Park, Xiamen City, Fujian Province
Mobile: +86-17750019513(WhatsApp)
Email: yy4291644@gmail.com
Website: https://www.abb-sis.com