SHINKAWA VM-771B MCL VIEW
VM-771B MCL VIEW
SYSTEM REQUIREMENTS
HARDWARE REQUIREMENTS
PC/AT compatible personal computer
Processor Intel Pentium® compatible (1GHz or higher)
processor clock speed recommended
Memory 4GB or higher recommended
Display 1024 X 768 or higher-resolution
Hard disk drive 15GB of available hard-disk space
Drive DVD-ROM drive
Network Ethernet 100 BASE-TX
SOFTWARE REQUIREMENTS
Category Model Edition Version
OS Microsoft® Windows® 10 (32/64bit) Pro or higher Any
Microsoft® Windows® 11 (64bit) Pro or higher Any
Others Microsoft® Windows® installer - 3.1 or later
Microsoft® .NET Framework - 3.5
CONNECTION
Supported devices : VM-7B Monitor, VM-7 Monitor*2
Total input : 4 devices (Max.)*3
*2 Modules with firmware versions V0.9.0 or later are required.
*3 Multiple concurrent communication requires a hub.
COMMUNICATION
Network : Ethernet 100Base-TX
Protocol : TCP/IP
RECORDING
SHORT TERM DATA
Data : Measured values of each modules
Acquisition interval : 1 sec.
Period : 1 week
LONG TERM DATA
Data : Maximum values and mean values of
measured values
Acquisition interval : 1 hour
Period : 3 years
SCREEN

Bar graph screen : Measured values are displayed in rectangular bars.
Relay status screen : Relay status and logic is displayed.
Trend graph screen : Short term data or long term data is displayed.
Range of short term data display
: 1 hour / 30 minutes / 15 minutes / 10 minutes /
5 minutes / 2 minutes
Range of long term data display
: 3 months / 1 month / 2 weeks / 1 week /
3 days / 1 day
Train screen : Displays measured values and the train diagram.
Detailed information window
: Monitor range and alarm set values are displayed.
DISPLAY DATA
MEASURED VALUES
GAP (bias) voltage indications, Digital indication of measured values
ALARM
DANGER alarm, ALERT alarm, OK alarm (NOT-OK), GAP alarm*4.
System OK alarm (SYSTEM-OK), Power OK alarm (POWER-OK)
*4 Outputs as ALERT alarm.
STATUS
DANGER bypass status, Channel bypass status,
Demo-mode (simulated value setting mode) status, Sequence mode status,
10-pole high-pass filter (10-pole low-cut filter) status, Peak hold status,
First-out status*5. Internal bus communication abnormality status*6.
Communication board install status*7
*5 Only the ALERT LED of the module first set off DANGER/ALERT alarm flashing.
*6 Only the ALERT LED on the left-end of the screen flashing.
*7 Only available of VM-7B Monitor.
SET VALUES
Channel name, Tag name, Serial number, Firmware ID*8. Monitor range,
DANGER alarm set values, ALERT alarm set values
*8 Only available of VM-7B Monitor.
CONTROL FUNCTIONS
RESET INSTRUCTION
Alarm reset, Peak hold reset, First-out reset
BYPASS INSTRUCTION
DANGER bypass, Channel bypass
OTHER FUNCTIONS
Password protection : Password authentication is executed to
the instruction of the control operation.
Screen capture
: Captures active screen in PNG form.
CSV output
: The data of the trend graph under the display is
output by Comma Separated Value.
SOFTWARE DISTRIBUTION MEDIA
Media
!
: DVD-ROM
WARNING
Some functions may not be available with old version.
For details, please refer to "infiSYS Family Improvement
Information" (6H16-011).
※ The specifications and other items indicated herein are subject to change without notice.
※ All company and product names in this brochure are trademarks or registered trademarks.
Default Value
Communication
IP Address (Rack1) : 192.168.8.8
IP Address (Rack2) : 192.168.8.9
IP Address (Rack3) : 192.168.8.10
IP Address (Rack4) : 192.168.8.11
Port Number (All)
: 8888
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
Add: High-tech Software Park, Xiamen City, Fujian Province
Mobile: +86-17750019513(WhatsApp)
Email: yy4291644@gmail.com