IBA Optical Signal Multiplier ibaBM-FOX-i-3o-D
Optical Signal Multiplier ibaBM-FOX-i-3o-D
Distributes one ibaNet line to 3 ibaNet lines
Supports 2Mbit, 3Mbit, 5Mbit and 32Mbit
Reserved bandwidth for Ethernet communication
The Ethernet channel (address 0) is used to transmit configuration data. If many devices
are configured with a lot of signals, it may happen, that only the minimum size of 1 kB/s
is reserved for Ethernet communication. This is not sufficient in many cases and may
cause, that the configuration data are transmitted only slowly or cannot be transmitted at
all.

It is now possible to reserve a fixed bandwidth for the Ethernet channel with the option
“Reserve bandwidth for ethernet communication“.
Operation as sniffer
When the device operates as sniffer, no configuration in the engineering tool of the used
EtherNet/IP scanners (master) is necessary.
To configure ibaPDA, knowledge concerning the structure of the transferred user data is
needed, basically the following information:
❑ Between which scanner and which adapter the data is transferred
❑ Will the data be transfered from the scanner to the adapter (OUTPUT) or will it be
transfered from the adapter to the scanner (INPUT)
❑ Where (Byte offset) in the slot data the corresponding signal is saved and which
data type is used.
A distinction must be made between (TCP) connections and (UDP) data streams. An
EtherNet/IP connection usually consists of one connection and two data streams (one in
each direction). The data streams are used for cyclic IO data exchange.
The following technical restrictions are to be taken into consideration:
❑ To detect the EtherNet/IP connection, the telegram traffic must be sniffed during
connection setup (CPU start-up, cable reconnection). If this is not the case, only the
running data streams are detected. In this case, it may be that the cyclic I/O data
cannot always be clearly assigned to EtherNet/IP connections. Data acquisition is
then not reasonably possible.
❑ A maximum of 1024 analog and 1024 digital signals from up to 64 bidirectional con
nections can be configured.
❑ Up to 1023 data streams and 511 connections can be displayed in the online diag
nostics.
Example for FO budget calculation
As an example, an FO connection from an ibaFOB-io-Dexp card (FO transmitter) to an
ibaBM-PN device (FO receiver) is used.
The example refers to a point-to-point connection with an FO cable of type 62.5/125 µm.
The light wavelength used is 850 nm.
The range of the minimum and maximum values of the output power or receiver sensi
tivity depends on the component and, among other things, on temperature and aging.
For the calculation, the specified output power of the transmitting device and on the other
side the specified sensitivity of the receiving device must be used in each case. You will
find the corresponding values in the respective device manual in the chapter "Technical
data" under "ibaNet interface"
| SCRIO-9627 783817-01 CompactRIO Single-Board Controller |
| REF620C_F NCFNAAAAABC2DNN1XF Feeder protection and control |
| 65040-PACV-AYU2/9049 Pendulum valve control system |
| 4000093-320 Input and output cables |
| UNITROL1000 UN1000a-Z,V3 3BHE005774R0003 brushless excitation system |
| UNITROL1000 UN1000b-Z,V3 3BHE014557R0003 brushless excitation system |
| PPC322AEV01 HIEE300697R1 PSR2-Power Supply |
| TC-501-02-4M5 Trusted TMR I/O SmartSlot Slot Cables |
| 1MRK002122-ABR02 Multi-channel analog-to-digital converter (ADC) module |
| 1788-EN2PAR Linking Device to Profibus PA Networks |
| REF615C_D HCFDACADAND2BNN1XD Feeder Protection and Control |
| REF615A_1G HAFNAEFCBGC1BQK11G Feeder Protection and Control |
| REF615E_1G HBFGDAAHNDCCBNA11G Feeder Protection and Control |
| REF615 HCFKAEADABCZDAA11E Feeder Protection and Control |
| PR6424/003-110+CON021 Eddy Current Signal Converter |
| NXL00045C1N1SSS00 vacon nx ac drives |
| TIS600-124-SIG Industrial Power Supplies TIS Series 5000 Watt |
| PPM3-6DG-6H3-1F1 Protection & power management PPM 300 |
| CI873K01 3BSE058899R1 CI871 Ethernet/IP Communication Kit |
| PPD517A3011 3BHE041576R3011 AC 800PEC Controls the CPU |
| P7LA HNEF105323R0002 Input and Output module |
| B5LA HENF327886R0001 Power conversion module |
| VMIVME4140-000 Discrete Wire 32-Channel 12-Bit Analog Output Board |
| AVR10D-Q22020 Model AVR10D Duplexed V net Router |
| IRDH575B1W-435 Insulation monitoring device |
| AX460/100010/STD Single and dual input analyzers for pH/Redox |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
Add: High-tech Software Park, Xiamen City, Fujian Province
Mobile: +86-17750019513(WhatsApp)
Email: yy4291644@gmail.com