The 3500/40M Proximitor Monitor is a four-channel monitor  that accepts input from Bently Nevada proximity transducers,  conditions the signal to provide various vibration and  position measurements, and compares the conditioned  signals with user-programmable alarms. The user can  program each channel of the 3500/40M with the 3500 Rack  Configuration Software to perform any of the following  functions:  l Radial  vibration  l Thrust  position  l Eccentricity  l REBAM  l Differential  expansion  The primary purpose of the 3500/40M Proximitor Monitor is to  provide the following:  l Machinery protection by continuously comparing  monitored parameters against configured alarm  setpoints to drive alarms                 l Essential machine information for both operations and  maintenance personnel  Each channel, depending on configuration, typically  conditions its input signal to generate various parameters  called static values. You can configure alert setpoints for  each active static value and danger setpoints for any two of  the active static values
Specifications
Inputs Signal Accepts from 1 to 4 proximity transducer signals Power consumption 7.7 watts, typical Input Impedance Standard I/O 10 kΩ (Proximitor and acceleration inputs TMR I/O The effective impedance of three bussed TMR I/O channels wired in parallel to one transducer is50 kΩ Sensitivity Radial Vibration 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil) Thrust 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil) Eccentricity 3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil) Differential Expansion 0.394 mV/μm (10 mV/mil) or 0.787 mV/μm (20 mV/mil) REBAM 40 mV/μm (1000 mV/mil) or 80 mV/μm (2000 mV/mil)
Accuracy
Direct and Gap Exclusive of filtering Within ±0.33% of full-scale typical ±1% maximum 1X and 2X Within ±0.33% of full-scale typical ±1% maximum Smax Within ±5% maximum Not 1X ±3% for machine speeds less than 30,000 cpm ±8.5% for machine speeds greater than 30,000 cpm Thrust and Differential Expansion Accuracy Within ±0.33% of full-scale typical ±1% maximum Frequency Response Direct filter-3 dB at 1.2 Hz Gap filter-3 dB at 0.41 Hz Eccentricity Accuracy Within ±0.33% of full-scale typical ±1% maximum Frequency Response Direct filter-3 dB at 15.6 Hz Gap filter-3 dB at 0.41 Hz
Environmental Limits
Operating Temperature When used with Internal/External Termination I/O Module:-30°C to +65°C (-22°F to +150°F) When used with Internal Barrier I/O Module (Internal Termination): 0°C to +65°C (32°F to +150°F) Storage Temperature-40°C to +85°C (-40°F to +185°F). Humidity 95%, noncondensing
Physical
Monitor Module (Main Board) Dimensions (Height x Width x Depth) 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in) Weight 0.91 kg (2.0 lb) I/O Modules (non-barrier) Dimensions (Height x Width x Depth) 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in) Weight 0.20 kg (0.44 lb) I/O Modules (barrier) Dimensions (Height x Width x Depth) 241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in) Weight 0.46 kg (1.01 lb