KONG -Y
NameDescriptionContent
Location:

3500 System Overview Bently Nedahua

From: | Author:kongjiang | Time :2025-02-17 | 543 Browse: | 🔊 Click to read aloud ❚❚ | Share:

3500 System Overview Bently Nedahua

Description 

 The 3500 System provides continuous, online monitoring suitable for machinery protection applications, and is designed to fully meet the requirements of the American Petroleum Institute’s API 670 standard for such systems.  It represents our most capable and flexible system in a traditional rack-based design, and represents numerous features and advantages not provided in other systems.   The system’s highly modular design consists of: 

 • 3500/05 Instrument Rack (required) 

 • One or two 3500/15 Power Supplies (required) 

 • 3500/22M Transient Data Interface or 3500/20 Rack Interface Module (required) 

 • One or two 3500/25 Keyphasor® Modules (optional) 

 • 3500 Rack Configuration Software (required) 

 • One or more 3500/XX Monitor Modules (required) 

 • One or more 3500/32 Relay Modules or 3500/34 TMR Relay Modules (optional) 

 • One or more 3500/92 Communication Gateway Modules (optional) 

 • 3500/93, 3500/94, or 3500/95 display OR 3500 Operator Display Software running on a compatible PC (optional) 

 • Internal or external intrinsic safety barriers, or galvanic isolators for hazardous area installations (optional) These are described in more detail in the following section and in the individual datasheets for each system component.  

System Components 

Rack   The full-size 3500 Rack is available in 19” EIA rail mount, panel-cutout-mount, and bulkhead-mount versions.  The rack provides slots for two Power Supplies and a Rack Interface Module in the left-most rack positions that are reserved exclusively  for these modules.  The remaining 14 slots in the rack can accommodate any combination of monitor, display, relay, Keyphasor module, and communications gateway modules.   All modules plug into the rack’s backplane and consist of a main module and an associated I/O module.  The I/O module installs at the rear of the rack for panel-mount systems, and above the main module for bulkhead-mount systems.   The rack depth is 349 mm (13.75 inches) and NEMA 4 and 4X weatherproof housings are available when required for environmental protection or when purge air is used.   A mini-rack (12” wide instead of 19”) is also available and features 7 available monitor slots instead of 14.  Like its larger counterpart, the left-most slots are reserved for the Power Supply or Supplies and Rack Interface Module.  The mini-rack may be mounted in a panel cutout or, using an optional adapter plate, on 19” EIA mounting rails.   Bulkhead mounting is not available.  

Power Supply 

The 3500/15 Power Supply can be ordered for ac or dc input power, providing compatibility with voltage sources worldwide.  Line noise filters are standard.   The 3500 Rack can operate from a single supply, or dual Power Supplies can provide redundancy for situations which cannot tolerate power interruption. Dual supplies reside in the upper and lower positions of the left-most rack slot.  Redundant Power Supplies can use with separate voltage sources.  For example, the primary (bottom) supply can be operate with 120 Vac power while the backup (upper) supply can be powered from an uninterruptible 24 Vdc source.   Each Power Supply can individually provide power to the entire rack and its modules.  When redundant supplies are used, one supply acts as primary power for the rack while the other acts as a backup, ready to instantly and automatically operate as the primary rack supply without interrupting rack functions., should the primary supply fail.   The 3500/15 Power Supply module has self monitoring functions that allow it to determine if all its output voltages are within specifications.  The module annunciates this via a green “Supply OK” LED on the Power Supply’s front panel.

Rack Interface Module/Transient Data Interface 

The Transient Data Interface (TDI) or the Rack Interface Module (RIM) are the 3500 Rack’s primary interfaces to the configuration, display, and condition monitoring software.  Each rack requireas one TDI or RIM, which resides in the rack slot immediately adjacent to the Power Supply slot. The TDI and RIM support a proprietary protocol used by both the 3500 Configuration Software to configure the rack and the 3500 Operator Display Software to retrieve rack data and statuses. TDI provides a direct interface with GE’s Bently Nevada  System 1® machinery management software without the need for an external communications processor.  The RIM requires an external communications processor, such as TDXnet™, TDIX, or DDIX to interface to Data Manager® condition monitoring software. The System OK relay1 is located within the TDI/RIM’s I/O module.  It is driven by NOT OK conditions within the TDI/RIM itself and within other modules in the rack.  

The TDI and RIM supply “self monitoring” functions both for themselves and for the rack, in addition to those provided by the individual monitor, relay, communications, and other modules.  While the TDI and RIM provide certain functions common to the entire rack, neither is part of the critical monitoring path and has no effect on the proper, normal operation of the overall 3500 System or its machinery protection functions.   The TDI and RIM provide 4 front-panel LEDs as follows: OK Indicates that the Rack Interface Module and its I/O modules are operating correctly. TX/RX Flashes at the rate that communications between the RIM and other rack modules are occurring. TM Indicates when the rack is in the Trip Multiply mode. CONFIG OK Indicates that any module in the rack is not configured or has a configuration error; that the stored configuration of the Rack Interface Module does not match the physical configuration of the rack; or that a security option condition was not met. System configuration is secured by means of a keylock switch on the front of the TDI/RIM and two levels of software password protection, preventing unauthorized changes to or tampering with the configuration.  Both the TDI and the RIM can be connected to a portable computer via a front-panel serial communications port for local changes to configuration.  The RIM can also be permanently connected to a configuration workstation via a rear panel serial communications port, or to a remote computer via an optional modem I/O module. The TDI provides permanent system connectivity via Ethernet ports. The TDI/RIM provides a front-panel DIP switch that permits the user to assign a unique rack address when multiple 3500 racks are networked with one another.   The TDI/RIM provides a system reset switch on the front panel, allowing the user to clear any latched alarms in the system as well as latched NOT OK conditions.  An I/O module provides a set of rear panel connections as well, allowing users to remotely activate this switch.   For Triple Modular Redundant (TMR) applications, the 3500 System requires a TMR version of the TDI/RIM (refer to the TMR section of this datasheet for additional information).   Notes:   1.  Dozens of possible event conditions within the rack can drive the NOT OK relay.  For this reason, it is not intended for use as part of a machinery auto-shutdown circuit and should be used for general annunciation purposes only.     Monitors   Table 1 summarizes available monitor types in the 3500 System.  Each monitor occupies a single slot in the rack.  All monitors are microprocessor-based and offer digitally adjustable Alert and Danger setpoints for each channel1.  Users can configure alarms for latching or non-latching operation.  Status indications for each monitor and channel are provided with bright, front-panel LEDs, allowing observation without operator interaction for easy and convenient operation. Most monitors provide independent 4 to 20 mA proportional outputs for each channel of the I/O module for connection to strip chart recorders or for older process control systems that do not support a digital interface. Where applicable, the monitor’s I/O modules provide transducers with appropriate power via short circuit-protected terminals.  OK detection routines within each monitor continuously check the integrity of each transducer and the associated field wiring.   Transducer input signals are buffered and sent to front-panel coaxial connectors2.  Buffered output terminals are also available upon request on the rear of the TDI/RIM’s I/O module.

  • AMAT 0100-00689 | VME PCB Power Module
  • AMAT 0100-00580 | VME Intelligent System Controller Board
  • AMAT 0100-00523 | VME Multi-Channel Analog-to-Digital (A/D) Board
  • AMAT 0100-00493 | VME Multi-Function System Controller Board
  • AMAT 0100-00398 | VME Interface System Control Board
  • AMAT 0100-00369 | VME 12-Channel High-Speed Stepper Motor Controller
  • AMAT 0100-00196 | VME System Mainframe CPU Controller Board
  • AMAT 0100-00169 | VME 12-Channel Stepper Motor Controller Board
  • AMAT 0100-00162 | VME Dual Channel Serial Communication Board
  • AMAT 0100-00137 | VME Stepper Motor Controller Interface Board
  • AMAT 0100-00075 | VME Digital Input/Output (DI/O) Interface Board
  • AMAT 0100-00007 | VME Analog Input/Output Interface Board
  • AMAT 0100-00002 | VME Slave I/O Interface PCB
  • AMAT 0090-05596 High-Voltage DC Power Cable Assembly
  • AMAT 0090-01809 High-Performance RF Power Cable Assembly
  • AMAT 0010-29958 CCM HART 3 Mainframe Control Assembly
  • AMAT 0010-20003 System Controller Card Cage Assembly
  • AMAT 0010-11239 PVD High-Voltage Power Interface Assembly
  • AMAT 0010-09416 RF Matching Network Assembly
  • AMAT 0010-00019 Analog Power Supply Assembly
  • AMAT AS00009-02 (31-000-00940) | Precision Semiconductor Component
  • AMAT 0010-00028 Power Supply Module
  • AMAT 0330-1586A Serial Communication PCB
  • AMAT 0190-09690 Seriplex SENSORbus SPX-MUXADIO-001
  • AMAT 0190-04397 DeviceNet I/O Interface Board
  • AMAT 0190-02506 DeviceNet I/O Interface Card
  • AMAT 0090-00475 Seriplex 210 MUXADIO
  • AMAT 410-0198-1 Multi-Output Switching Power Supply
  • AMAT 0100-20458 high-reliability Configurable Interlock Personality Board
  • AMAT VAS104350-0415 Gasline Heater Control Unit
  • AMAT VME6U1V2 VMEbus Backplane Interface Module
  • AMAT 0920-01070 high-performance RF Power Generator
  • AMAT 0090-76133A VME Single Board Computer (SBC)
  • AMAT 0190-24115 DeviceNet I/O Interface Card
  • AMAT 0190-37607 Backplane / Base Board Assembly
  • AMAT 0190-32372 Analog Input/Output (I/O) Board
  • AMAT 0190-09956 Loadlock Interface PCB Base Assembly
  • AMAT 0190-07908 four-channel DeviceNet Interface Card
  • AMAT 0190-07905 (UPS) control board
  • AMAT 0190-07502 Precision Controller / Interface Board
  • AMAT 0190-03680 I/O Backplane
  • AMAT 0190-02200 Water Leak Detection Control Board
  • AMAT 0100-76124 Digital I/O Board Assembly
  • AMAT 0100-35563 Leak Detector Configuration PCB
  • AMAT 0100-35250 Chamber Interface DPS Centura PCB
  • AMAT 0100-35124 Seriplex I/O Distribution Board
  • AMAT 0100-35058 Loadlock Interlocks PCB
  • AMAT 0100-20213 RF Match Detector PCB
  • AMAT 0100-20063 Interface PCB Assembly
  • AMAT 0100-09225 TC AMP/INTERLOCK PCB
  • AMAT 0100-09153 Gas Panel Interface PCB
  • AMAT 0100-09127 Loader Interconnect Board
  • AMAT 0100-09009 Buffer I/O PCB Card
  • AMAT 0100-02813 Signal Conditioning Board
  • AMAT 0100-01911 AC Gas Heater Control Board
  • AMAT 0100-01708 Pedestal Integration PCB
  • AMAT 0100-00658 300mm RTP Controller Distribution PCB
  • AMAT 0100-00582 Gas Panel Controller Backplane
  • AMAT 0100-00049 Analog Signal Conditioner
  • AMAT 0100-00008 Control Interface Module
  • AMAT 0090-03402 DC Power Supply / Power Module
  • AMAT 0090-01248 DC Power Supply / Power Module
  • AMAT 0090-76109 RF Matching / Capacitor Assembly
  • AMAT 0101-57106 Substrate Voltage Board
  • AMAT 0101-57014 Deflection-Amplifier PCB
  • AMAT 0101-57012 AKT Column Control PCB (COL-C 50-10)
  • AMAT AKT 0241-58482 PCB board card
  • AMAT 0241-58255 REV05 PCB
  • AMAT 0161-57042 AKT framework
  • AMAT 0101-57196 electronic control board
  • AMAT 0101-57178 Digital Input / Interface PCB
  • AMAT 0101-57162 electronic control board
  • AMAT 0101-57127 P-DRV (Power Driver Board)
  • AMAT 0101-57126 D-AMP 50-06 (Digital/Analog Amplifier)
  • AMAT 0101-57125 AKT COL-C Communication Board
  • AMAT 0101-57120 D-OUT 50-32 (Digital Output Board)
  • AMAT 0101-57112 D-IN 50-32 (Digital Input Board)
  • AMAT 0101-57102 electronic control board
  • AMAT 0101-57065 high-precision Ion Implanter Component
  • AMAT 0100-71278 high-performance VME Communication Interface Board
  • AMAT 0100-71134 control module
  • AMAT 0100-71075 high-performance VME Communication/Control Interface Board
  • AMAT 0100-71047 safety and logic control module
  • AMAT 0660-01699 5-Channel Convectron Gauge Controller
  • AMAT 0660-01635 control module
  • AMAT 0660-01534 Communication or logic control board card
  • AMAT 0190-52419 Processor Module
  • AMAT 0190-36769 high-density communication interface card
  • AMAT 0190-35776 Seriplex Multiplexed I/O Control Board
  • AMAT 0190-35775 VME Bus Interface / Controller Board
  • AMAT 0190-35653 Applied Materials G6 FPD Digital I/O Interface
  • AMAT 0190-30079 | Applied Materials CDN496R DeviceNet I/O PCB
  • AMAT 0190-26873 Applied Materials Delta Tau Turbo PMAC2 CPU Motion Control Card
  • AMAT 0190-25911 Applied Materials HDPCVD Interlock Board
  • AMAT 0190-23509 Applied Materials Advanced DeviceNet Scanner Pro Module
  • AMAT 0190-17952 Applied Materials Advanced DeviceNet Interface Card
  • AMAT 0190-16926 Applied Materials G6 FPD Thermal Control Interface
  • AMAT 0190-14903 | Applied Materials 4-Port DeviceNet CPCI Interface Module
  • AMAT 0190-07906 Applied Materials MESA DC/DC Power Supply Card
  • AMAT 0190-07847 Applied Materials SBS PCMIP SLOT 4 II Carrier Board
  • AMAT 0190-07451 Applied Materials CPCI 32/16 Analog I/O Interface Board
  • AMAT 0190-06279 | Applied Materials Digital I/O Interface Module
  • AMAT 0190-04745 Applied Materials CDN494 Analog I/O Interface Board
  • AMAT 0190-02774 Applied Materials Advanced Interface Module
  • AMAT 0101-57017 PCA, AKT MUX (Multiplexer) Board
  • AMAT 0100-76042 PCA, Digital I/O Interface Board (76K Series)
  • AMAT 0190-35310 0100-35175 PCA, Viking Interconnect Board Viking Valve Manifold Assembly
  • AMAT 0100-09162 H-Bridge Stepper Motor Driver PCB manufactured for Applied Materials
  • AMAT 0100-09115 high-precision Analog Input PCB (Printed Circuit Board)
  • AMAT 0100-09102 ower and Signal Distribution PCB
  • AMAT 0100-09099 PCA, System Controller / VME Interface Board
  • AMAT 0100-02735 Digital input/output (input/output) interface printed circuit board
  • AMAT 0100-01577 PCB, Step/Direction Motor Interface
  • AMAT 0100-00957 Simulation Input/Output (A-I/O) Control Printed Circuit Board
  • AMAT 0100-00048 Diagnostic/Interface PCB
  • AMAT 0100-00011 PWM (Chopper) Constant Current Drive
  • AMAT 0100-00003 B-Sized VME Module
  • AMAT 0101-57144 AKT Multiplexer
  • AMAT 0100-71121 AKT Chamber Control CVD 25K Board
  • AMAT 0190-24116 Analog I/O Plugin Module
  • AMAT 0190-72235 Viking Valve / Diaphragm Valve
  • AMAT 0190-08680 Special dual-channel DeviceNet scanning card
  • AMAT 0190-26769 high-performance Universal Vacuum Gauge
  • AMAT 0090-04247 high-performance ATX Power Supply Module
  • AMAT 0190-23623-001 RF Impedance Matching Network
  • AMAT 0190-26495 6-Channel Temperature Controller
  • AMAT 0190-26463 Temperature Controller / Thermal Control Module
  • AMAT 0190-22205 6-Channel Temperature Controller