ABB 3HAC7681-1
Important
All control parameters are determined in an optimum way for most actuators during Autoadjust. Changes should only be made when Autoadjust cannot be executed or control stability cannot be achieved.
The positioner issues an amplified positioning signal for the defined pulse length and with the actuator not moving, in order to achieve accelerated starting of the actuator. This improves the dynamic, in particular, for small setpoint changes.
To compensate for existing dissymmetries in the controlled system, the go pulse should be set separately for both directions (up/down).
If the control response consistently overshoots the setpoint, decrease the go pulse. For small and fast actuators, it may be necessary to set the go pulse to 0, even if Autoadjust has determined a higher value.
Important
The value determined by Autoadjust should not be increased, as this may result in overshooting!
You can use parameter GOPULSE DN to move the go pulse for adjustment towards 0 %.
3BSE018296R1
DSDI 120AV1 Digital Input Board 32
3BSE018297R1
DSDX 180AK02 DI/DO Module, 32ch
3BSE018298R1
DSDO 115A Digital Output Board 32 Channe
3BSE018311R1
DSTA 171 Connection Unit for Analog
3BSE018405R1
TC513V1 AF100 Twisted pair Coax Modem
3BSE018451R1
CI522AK04 AF 100 Comm. Interface
3BSE018452R1
CI522AK05 AF 100 Interface for Bus
3BSE018453R1
CI522AK06 AF 100 Interface for Bus
3BSE019210R15
TK626V115 Cable assembly
3BSE019210R5
TK626V050 Cable assembly
3BSE019419R1
Label Set S800L, 16ch
3BSE019419R2
Label Set S800L, 8ch
3BSE019999R1
DSRF 197K01 I/O Subrack with single 5V
3BSE020178R1
DSRF 200K01 I/O Subrack with redundant
3BSE020508R1
DI801 Digital Input 24V 16 ch
3BSE020510R1
DO801 Digital Output 24V 16 ch
3BSE020512R1
AI801 Analog Input 8 ch
3BSE020514R1
AO801 Analog output 8 ch
Add: Building F05, High-tech Software Park, Xiamen City, Fujian Province
Tel: 0592-5211302
Mobile: 17750019513 (WhatsApp)
Email: yy4291644@gmail.com
ivy@kongjiangauto.com
Website: https://www.abb-sis.com