ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G

From:ABB | Author:kongjiang | Time :2026-06-17 | 133 Browse: | 🔊 Click to read aloud ❚❚ | Share:

ontinuous Gas Analyzers AO2000 Series

AO2040CU Ex   Central Unit in Category 2G

Cable opening M20 for power supply on the control unit for the pressurized

enclosure system

Cable openings for internal wiring connections

Connection plate with 6 black cable openings M20 for non-intrinsically safe

wiring (some cable openings are used for internal wiring connections)

Metallic cable opening M20 for the shielded system bus cable of the

AO2060-... analyzer module

Cable opening M20 for the 24-VDC connection cable of the

AO2060-... analyzer module

Potential compensation connectors

3 light blue cable openings M20 for intrinsically safe wiring

Threaded Cable

Connections

Permissible Cable

Diameters

Inserting the Cable in

the Housing

Type of Connector

Application

Light blue M20 connector Intrinsically safe connecting leads

Black M20 connector

Non-intrinsically safe connecting leads, AO2060-...

analyzer module 24 VDC connecting cable

Metallic M20 connector

AO2060-... analyzer module system bus cable (see

page 14 for special notes and instructions)

The M20 threaded connectors are suitable for cables with outer diameters of

6-12 mm.

Step Action

1

Remove the cap nut on the threaded connector and remove both seal

rings.

2

Slide the cap nut 1 and seal rings over the cable.

6-8 mm OD Cable: Use seal rings 2 and 3.

8-12 mm OD Cable: Use seal ring 2 only.

Pass the cable through the intermediate openings 4 in the housing.

4

Tighten cap nut 1 (torque to 2.5 Nm).

Sealing Unused

Cable Connections

• Only the manufacturer’s original equipment plugs should be used to close off the

threaded cable connectors.

• Unused cable connectors must be closed off with factory-provided plugs.

• Securely tighten the cap nuts on the unused cable connectors (torque to 2.5 Nm).

AO2040-CU Ex Central Unit Electrical Equipment

Device

Description

For Connection, See -K01 -K02 -K03 -K04

Isolation relays (-K01 standard, -K02 through -K04 optional) for system bus and

non-intrinsically safe signal leads, maximum load 30 VDC/0.4 A

Page 15 -K05

Terminal strip for connecting the 8-wire AO2060-... analyzer module system bus

cable leads not connected to isolation relay -K01

Page 13 -Z01

Line filter for connecting the 3-wire AO2060-... analyzer module 24 VDC cable

Page 13 -B01

Pressurized enclosure system control unit, power supply (230 VAC or 115 VAC,

non-adjustable) status signal pe

< 1.2 hPa

Page 21 -B02

ER 144A/Ex isolation amplifier (option) for condensate monitor,

intrinsically safe connection, EEx ia IIC input current circuit,

electrical specifications per EC type certification TÜV No. 00 ATEX 1604

Page 16 -B03.1 -B03.2

Contrans I V17131-530 isolation amplifier (option) for flow monitor,

intrinsically safe connection, EEx ia IIB/IIC or EEx ib IIB/IIC input current circuit,

electrical specifications per EC type certification PTB 99 ATEX 2119

Page 17 -B04.1 -B04.2 -B04.3 -B04.4

Contrans I V17153-510 passive isolator (option) for current output,

intrinsically safe connection, EEx ib IIB/IIC output current circuit,

electrical specifications per EC type certification PTB 00 ATEX 2017X

Page 18 -B05.1 -B05.2 -B05.3

Contrans I V17132-520 valve control unit (option) for solenoid valves,

intrinsically safe connection, EEx ib IIC output current circuit,

electrical specifications per EC type certification PTB No. Ex-96.D.2013

Page 19 -B06.1 -B06.2

Contrans I V17133-510 isolation relay (option) for switch contact,

intrinsically safe connection, EEx ia IIB/IIC or EEx ib IIB/IIC switch contact circuit,

electrical specifications per EC type certification PTB 99 ATEX 2067X

AO2060-... Analyzer

Module Connecting

Cables

System Bus

The following cables are factory-connected to the AO2060-... analyzer module:

• 10 meter system bus cable (8 x 0.5 mm2) and

• 10 meter 24 VDC connecting cable (3 x 2.5 mm2).

The cables are routed through pressure-tight cable passages.

Connecting

AO2060-...

Analyzer Module to

AO2040-CU Ex

Central Unit

Use of a

Connection Box

System Bus

Termination Resistor

Total Length of

System Bus Wiring

Normally the following connections are made (see Figure 4):

• System bus cable to isolation relay -K01 and to terminal strip -K05 and

• 24 VDC connecting cable to line filter -Z01.

A connection box should be used if the AO2060-... analyzer module cable is too

short or multiple AO2060-... analyzer modules are to be connected to the

AO2040-CU Ex central unit.

For additional information and connecting diagrams see the AO2060-... analyzer

modules operator’s manual (publication number 42/24-12 EN).

In the AO2040-CU Ex central unit, the system bus termination resistor is attached

to the electronics module.

The total system bus wiring length should not exceed 350 meters.



  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • ADLINK SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO  HSL-4XMO-TB-D103  HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • ADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840
  • Adlink PICMG Single Board Computers NuPRO-935A
  • ADLINK ADLINK NuPRO-841 REV:1.0 PICMG Single Board Computers
  • ADLINK PCI-8254 / PCI-8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NUPRO-780 PICMG Single Board Computers
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • Adlink Technology 51-37111-0C1 cPCI-R8217 cPCI-R3700A PCB Interface Card
  • ADLINK DPAC-3020-11(G) Embedded PC Automation Controller
  • ADLINK NuPRO-840 PICMG 1.0 industrial Single Board
  • Adlink 6U CompactPCI 2.0 Blades cPCI-6965
  • ADLINK PCI-9114DG Multi-Function DAQ Card
  • Adlink NuPRO-E43 PICMG Single Board Computers
  • Adlink PCI-7856 Distributed Motion Control
  • ADLINK Mini-ITX Embedded Boards MI-965
  • ADLINK NuPRO-E340 ICMG Single Board Computers
  • ADLINK NuPRO-595 Series Full-Size PICMG 1.0 SBC
  • ADLINK PCIe-GIE64+ / PCIe-GIE62+ 4 / 2-CH PCI Express® Power over Ethernet Frame Grabbers
  • ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC