Safety Summary (continued)
Operating Environment
Before the AC 800M Controller system is brought online, investigate which environmental conditions are applicable. Take note in particular of the following:
• The controller must not be exposed to conditions that exceed the values given in the relevant technical specifications.
• The controller must not be used in an environment exposed to strong electrical interference. Electrical machines can produce interference that exceeds levels permitted for the equipment, for example during repair work. • All products must be handled with appropriate precautions with regard to electrostatic damage.
• The controller must not be exposed to direct sunlight.
Important Software Check
• Use the system’s fault-monitoring facilities to prevent accidents or mishaps.
• When in doubt, ALWAYS CHECK before executing changes. Important Hardware Notice
• DO NOT, under any circumstances, disconnect the power supply to a normally functioning system. Always use the correct system shut-down procedure prior to disconnecting the power supply.
Signal Noise Due to Cables Cables which may cause electrical interference (for example, power supply cables) must not be installed adjacent to bus cables carrying fast digital signals. Ensure that a minimum distance of 10 cm (4 in.) is provided between cables installed inside cabinets.
Hazardous Electrical Supplies Operational and maintenance procedures, during which personnel may come into contact with high voltage, should only be carried out by personnel fully trained in the maintenance of electrical equipment within those environments, and who are fully aware of all risks involved.
Electrostatic Sensitive Device Devices labeled with this symbol require special handling precautions as described in the installation section.
Equipment Environment All components, whether in transportation, operation or storage, must be in a noncorrosive environment. Electrical Shock Hazard During Maintenance Disconnect power or take precautions to insure that contact with ener gized parts is avoided when servicing.
ABB CH-3185 3BHL000986P1006
ABB 500MBA01 1MRB150003R0002 1MRB200053/L
ABB 500MBA02 1MRB150003R000/B
ABB 500MBA02 1MRB150003R0003 1MRB200053/M
ABB 3BHE022294R0103 GFD233A103
ABB 3BHE023784R1023 PP D113 B01-10-150000
ABB 3BHE004573R0145 UFC760BE145
ABB 4LA41100102V1.2 KB2
Controller PLC- robot servo drive-electro-hydraulic servo valve -DCS system/distributed control system
System frame-communication adapter-analog output-analog input-digital output-digital input-mechanical protection system-high-speed central processor-multi-meter watt-hour meter-ignition circuit board-crimping terminal-electric AC drive-low-voltage DC power supply module-electro-hydraulic servo valve-automatic control system-switch-network communication module-controller-processor module-generator-motor-servo drive-touch screen-input and output module- Unified-thermoelectric control system-thermal power generation system-wind power generation system-medium and high voltage frequency conversion system-precision motion system-programmable control system -DCS distributed control system-steel control system-steam turbine system-power generation system-power system-chemical inspection system-petroleum control system-tension monitoring system.
Add: Building F05, High-tech Software Park, Xiamen City, Fujian Province
Tel: 0592-5211302
Mobile: 17750019513 (WhatsApp)
Email: yy4291644@gmail.com
ivy@kongjiangauto.com
Website: https://www.abb-sis.com