KONG -Y
NameDescriptionContent
Location:

VM600Mk2/ VM600 ABE056 slimline rack Vibro-Meter

From: | Author:kongjiang | Time :2025-02-28 | 986 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Виброметр VM600Mk2 / VM600 ABE056

KEY FEATURES AND BENEFITS

• From the vibro-meter ® product line • 19 ″ slimline rack with a standard height of 1U • Robust metal construction • Modular concept allows specific modules (cards) to be added for machinery protection or condition monitoring • Cabinet or panel mounting • Backplane supporting the VM600Mk2/ VM600 system’s Open collector (OC) bus, and power supply distribution • Integrated AC-input or DC-input power supply • Power supply check relay

APPLICATIONS

• VM600Mk2/ VM600 machinery protection and/ or condition monitoring systems

DESCRIPTION

The VM600Mk2/ VM600 ABE056 slimline rack is used to house hardware for the VM600Mk2/ VM600 series of machinery protection and/or condition monitoring systems, from Meggitt’s vibro-meter ® product line. The VM600Mk2/ VM600 ABE056 slimline rack has a standard height of 1U and provides mounting space (rack slots) for one single-width VM600Mk2/ VM600 processing module (card pair) and a relay module (card). This rack is particularly suitable for industrial environments, where equipment must be permanently installed in 19 ″ cabinets or panels. Different versions of the integrated RPS1U power supply enable a VM600Mk2/ VM600 ABE056 slimline rack to be powered using either an external AC or DC mains supply. Both the power supplies support a wide input voltage range. The rack has an integrated backplane that provides the electrical interconnections between the integrated power supply (RPS1U) and the installed VM600Mk2/ VM600 modules (cards). It also includes a power supply check relay, available at the rear of the rack, which indicates

DESCRIPTION (continued)

that the integrated power supply is operating normally. VM600Mk2/ VM600 processing modules (cards) are installed in the front of the rack and the associated input /output modules (cards) are installed in the rear. The input /output modules (cards) provide connectors for the connection of sensors/measurement chains and for the sharing of various signals with external systems such as a DCS or PLC. In general, VM600Mk2/ VM600 ABE056 slimline racks are configured in the factory before delivery so they are supplied ready-to-use. Optionally, each module (card) can be reconfigured to meet the needs of a particular machinery monitoring application using the appropriate software package from Meggitt Vibro-Meter : VibroSight ® or VM600 MPSx. For further information, contact your local Meggitt representative.

General

Housing : Zinc-plated painted sheet steel Colour :Grey white (RAL 9002) Power supply :An integrated RPS1U power supply provides the VM600Mk2/ VM600 rack itself and all installed modules (cards) with + 5 VDC and ±12 VDC. See also AC-input power supply on page 3 and DC-input power supply on page 3. Power supply input : The power supply input has an AC or DC connector (with an RFI filter) and an on/off switch. See Ordering information on page 6 for information on mains power supply leads (power cords). Backplane :Proprietary VM600Mk2/ VM600 rack bus (Open collector (OC) bus) for data/signal sharing between modules (cards) Rack slots (module (card) positions) : Front of rack: 

 • 1 × slot – module (card) position 01 – for a processing module (card) such as MPC4Mk2, XMx16, MPC4 or AMC8. Rear of rack: 

 • 1 × slot – module (card) position 01 – for an associated input / output module (card) such as IOC4Mk2, XIO16T, IOC4T or IOC8T. 

 • 1 × slot – module (card) position 00 – for an associated relay module (card) such as RLC16Mk2 or RLC16. See also Mechanical drawings on page 5. Notes In general, associated input /output modules (cards) are required while relay modules (cards) are optional. For safety reasons, any VM600Mk2/ VM600 rack slot not populated by a module (card) must be covered by a blank panel.

SPECIFICATIONS (continued)

Rack slot number coding : For modules (cards) installed in the rear of the ABE056 rack, an electronic keying mechanism known as slot number coding is used to help ensure that the module (card) is installed in the correct slot, as defined by the configuration (that is, by the VibroSight ® or VM600 MPSx software). For ABE056 racks, the rack’s slot number is configurable by DIP switch and slot number coding requires that the rack’s slot number is set to match the slot number used by the module (card). Slot number coding range : 0 to 12 Slot number coding defaults : Factory assigned default values as follows: 

 • Slot 01 = 1 (0001 binary) for an ABE056 rack configured for use by a VM600Mk2 system such as a VM600Mk2 MPC4Mk2 + IOC4Mk2. 

 • Slot 01 = 3 (0011 binary) for an ABE056 rack configured for use by a VM600 system such as a VM600 MPC4 and IOC4T. Notes For a VibroSight / VM600Mk2 MPC4Mk2 + IOC4Mk2 system, the ABE056 rack DIP switch must be set to 01, as this is the default slot number used by the VibroSight Protect configuration software for an ABE056 rack (VM600 – 1U). For a VM600 MPSx / VM600 MPC4 and IOC4T system, the ABE056 rack DIP switch is typically set to 03, as this is the default slot number used by the VM600 MPSx configuration software for the ABE056 rack (VM600 – 1U).

  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • ADLINK SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO  HSL-4XMO-TB-D103  HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • ADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840
  • Adlink PICMG Single Board Computers NuPRO-935A
  • ADLINK ADLINK NuPRO-841 REV:1.0 PICMG Single Board Computers
  • ADLINK PCI-8254 / PCI-8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NUPRO-780 PICMG Single Board Computers
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • Adlink Technology 51-37111-0C1 cPCI-R8217 cPCI-R3700A PCB Interface Card
  • ADLINK DPAC-3020-11(G) Embedded PC Automation Controller
  • ADLINK NuPRO-840 PICMG 1.0 industrial Single Board
  • Adlink 6U CompactPCI 2.0 Blades cPCI-6965
  • ADLINK PCI-9114DG Multi-Function DAQ Card
  • Adlink NuPRO-E43 PICMG Single Board Computers
  • Adlink PCI-7856 Distributed Motion Control
  • ADLINK Mini-ITX Embedded Boards MI-965
  • ADLINK NuPRO-E340 ICMG Single Board Computers
  • ADLINK NuPRO-595 Series Full-Size PICMG 1.0 SBC
  • ADLINK PCIe-GIE64+ / PCIe-GIE62+ 4 / 2-CH PCI Express® Power over Ethernet Frame Grabbers
  • ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC