Using IPL600 and an IP or a dedicated serial port connection between a host PC and an S600+, you can transfer and receive configuration files (reports, Modbus configurations, customised displays, and LogiCalc programs). While included as the Config Transfer utility in Config600, IPL600 has a standalone use for situations when you do not need the full functionality of Config600. Details on using Config Transfer/IPL600 are provided in the Config600 Software User Manual (Part D301220X412).
1.3.1 Config600 Lite
Use the Config 600 Lite software editor suite to modify pre-developed configurations, transfer existing configurations, edit items on the front panel display, and customise reports.
Note: You typically use Config600 Lite to custom-configure a new S600+ during installation.
With Config600 Lite you can:
Edit process configuration data, including orifice size, analog input scaling, alarm limits, and keypad values.
Build and customise Modbus slave maps, Modbus master polling sequences, front panel displays, and period report formats.
Customise the alarm system, including alarm groups, suppression, and inhibits.
Configure system security by setting user names and passwords, and assigning access levels for each data object on the displays.
Specify the engineering units and totalisation rollover value.
Reflash the CPU module firmware with software upgrades and transfer configurations via the Config Transfer utility (IPL600).
Config600 Lite Plus
The Config600 Lite Plus software editor suite provides all the functionality of the Config600 Lite suite, but adds the ability to create a configuration file.
With Config600 Lite Plus you can:
Create a new application from base templates for gas, liquid, and prover applications.
Edit process configuration data, including orifice size, analog input scaling, alarm limits, and keypad values.
Build and customise Modbus slave maps, Modbus master polling sequences, front panel displays, and period report formats.
Customise the alarm system, including alarm groups, suppression, and inhibits.
Configure system security by setting user names and passwords, and assigning access levels for each data object on the displays.
Specify the engineering units and totalisation rollover value.
Reflash the CPU module firmware with software upgrades and transfer configurations via the Config Transfer utility (IPL600).
Config600 Pro
configurations, modify existing configurations, transfer existing configurations, edit items on the front panel display, and edit custom reports.
With Config600 Pro you can:
Create a new application from base templates for gas, liquid, and prover applications.
Edit process configuration data, including orifice size, analog input scaling, alarm limits, and keypad values.
Build and customise Modbus slave maps, Modbus master polling sequences, front panel displays, and period report formats.
Specify the engineering units and totalisation rollover value.
Customise the alarm system, including alarm groups, suppression,
text, and inhibits.
Configure system security by setting user names and passwords,
and assigning access levels for each data object.
Add and remove objects from the database.
Program special features using LogiCalc.
Reflash the CPU module firmware with software upgrades and
transfer configurations via the Config Transfer utility (IPL600).
Additional Technical Information
Refer to the following technical documents (available at
www.Emerson.com/EnergyandTransportation) for additional and
most-current information.
Table 1-1. Related Technical Information
Name Form Number Part Number
FloBoss™ S600+ Flow Computer S600+ D301151X412
Config600™ Configuration Software Config600 D301164X012
Config600™ Configuration Software User Manual A6169 D301220X412
Preparing for Installation
Add: Building F05, High-tech Software Park, Xiamen City, Fujian Province
Tel: 0592-5211302
Mobile: 17750019513 (WhatsApp)
Email: yy4291644@gmail.com
ivy@kongjiangauto.com
Website: https://www.abb-sis.com