KONG -Y
NameDescriptionContent
Location:

UNIOP EPALM10-DA71 state-of-the-art handheld HMI

From:UNIOP | Author:kongjiang | Time :2026-02-05 | 266 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Graphical display 120x64 pixels (up to 8 lines

20 characters)

• Highly visible transflective LCD display

• 27-keys keypad with tactile feedback

• Connection to industrial bus systems

• Large memory size (512 KB Flash)

• IP65 protection

• Includes Emergency Stop button

• Includes enabling switches, normal or 3

positions

• Available in version for connection to Ethernet

and Profibus DP

The ePALM HMI panels are the handheld products of the UniOP family. All of the ePALM products

support the rich common functionality of the UniOP operator panels:

• Versions available for connection to

Ethernet and Profibus DP. Ethernet

version allows connection to field devices

as well as programming the HMI from

Designer.

• Powerful and intuitive programming with

the UniOP Designer 6 software

• Support of more than 130 communication

drivers for industrial devices

• Transflective LCD display ensures

readability under the most critical light

conditions

• Display dynamic data in numerical, text,

bargraph and graphic image formats

• Recipe data storage. Recipe data can be

transferred to a host computer using the

Ethernet connection.

• Multilanguage applications. The number

of runtime languages is limited only by the

available memory. All text information in

the application can be exported in Unicode

format for easier translation.

• Powerful macro editor to configure

keypad operation

• Alarms and historical alarm list. Alarm

and event information can be printed or

transferred to a host computer using the

Ethernet connection.

• Eight level password protection.

• Report printing to serial printer. Reports

are freely configurable using Designer.

• Ethernet-based UniNet network to share

data between UniOP HMIs and to serve

data using UniNet OPC Server.

In addition some unique features make the

ePALM10 a perfect fit for handheld operation.

• Emergency Stop button. Hardwired.

• Enabling switches. Hardwired.

• High-quality polyurethane cable for

mobile applications

Model Cable Type/Length PC/Printer Port PLC Port Module Enabling switches

ePALM10-0061 Serial/5m Yes Yes - two normal

ePALM10-0062 Serial/10m Yes Yes - two normal

ePALM10-3P61 Serial/5m Yes Yes - one 3-position

ePALM10-3P62 Serial/10m Yes Yes - one 3-position

ePALM10-0066 Ethernet/5m - - SCM11 one 3-position

ePALM10-0068 Ethernet/10m - - SCM11 one 3-position

ePALM10-0067 Profibus DP/10m Yes - TCM08 one 3-position

ePALM10-0069 Profibus DP/5m Yes - TCM08 one 3-position

Enabling switches are implemented in two different solutions in the various ePALM models:

Two independent 2-positions switches with NO contacts

One 3-positions switch with two NO contacts

The operator must operate the two independent 2-positions switches simultaneously. The two

normally open contacts are wired directly to the controller.

The 3-positions switch must be operated as described in the table.

Position Button status Contacts Function

1 Released Open Not enabled

2 Pressed Closed Enabled

3 Pressed completely Open Panic

The switch provides two normally open contacts to be wired directly to the controller.

3.2 Indicators and Keypad

The standard keypad of the ePALM panels is shown in the figure below.

Custom artwork may be designed and produced on request. Please inquire for more information.

Battery Replacement

A Lithium battery is required for data back-up. The battery maintains the following data:

• Hardware real time clock

• Event list

• Recipe data

Note:  replacing the battery will cause the loss of the data maintained by the battery.

To replace the battery follow the procedure listed below:

1) turn off the power to the device

2) using a screwdriver loose the 6 screws securing the plastic enclosure

3) open the handheld; the battery is located on the CPU subsystem

4) remove the battery

replace the battery with a new one

6) close the handheld and tighten the six screws

7) apply power to the handheld and check that the battery good status is reported.

The unit must always be grounded to protection earth (PE). Grounding helps limit the effects of noise

due to electromagnetic interference on the control system.

The power supply circuit may be floating or grounded. In the latter case connect to ground the power

source common as shown in figure 4 with a dashed line.

When using the floating power scheme, note that the panels internally connect the power common to

ground with a 1 M resistor in parallel with a 3.3 nF capacitor.

The power supply must have double or reinforced insulation

The suggested wiring for the power supply is shown in figure 4.

All the electronic devices in the control system must be properly grounded. Grounding must be

performed according to applicable regulations.

3.5 Applicable Regulations

Regulations and recommendations have been issued in Europe covering the main safety-related issues

in control systems, which include operator interfaces.

EN 60204-1 lists some important guidelines applicable when using operator interfaces.

9.2.4 Suspension of safeguards

9.2.5.3 Stop

9.2.5.4 Emergency stop

9.2.5.6 Hold-to-run controls

9.2.5.7 Two-hand controls

9.4 Control function in case of failure

Do not use operator interface to directly command motors, valves or other actuators not equipped with

safeguards and potentially harmful to persons or equipment in case of fault to the unit.

The service personnel, when operating directly on the powered unit, must be electrostatically

discharged.

All safety related regulations must be observed.

Installation Environment

The equipment is not intended for continuous exposure to direct sunlight. This might accelerate the

aging process of the front panel film.

The equipment is not intended for installation in contact with corrosive chemical compounds. Check

the resistance of the front panel film to a specific compound before installation.

3.7 Cleaning Faceplates

The equipment must be cleaned only with a soft cloth and neutral soap product. Do not use solvents.

3.8 Getting Started

ePALMs  must be programmed with the Designer software.

To program an ePALM you will have to connect it to a personal computer running the Designer

software; the ePALM must be in Configuration mode to be programmed.

3.8.1 Serial Communication

Make sure that Designer is correctly configured to communicate with the communication port to

which the cable attached.

The serial communication parameters between the panel and the personal computer are:

speed: 9600/38400 baud

parity: None

stop bit: 1

The Designer software defaults to the correct parameters.

3.8.2 Ethernet Communication

When applicable, Designer can use Ethernet to connect to the panel. Make sure all network

parameters are properly set to ensure communication between Designer and the panel.

The version of Designer software must be compatible with the firmware version of the panel to be

programmed. Call technical support for more information on compatibility between firmware and

programming software.

3.9 Troubleshooting

In the case it might be impossible to switch the handheld to Configuration Mode due to problems in

the start-up phase, follow the procedure described below:

1.  Switch off the unit

2.  Press and hold any 3 keys

3.  Turn on the unit and hold the keys pressed until Configuration Mode will be shown on the screen.

Connections

The ePALM10 is available in several versions, featuring different communication cables and different

solutions for the enabling switches.

4.1 Serial Communication - Types –0061 and –0062

ePALM types –0061 and -0062 include all standard UniOP connections and are suitable for all

common serial communication links.

The ePALM10-0061 includes a communication cable with a length of 5 meters.

The ePALM10-0062 includes a communication cable with a length of 10 meters.

The cable does not have a connector at its loose end as it is intended to be wired directly in the control

cabinet.

The following groups of signals are available in the cable:

PC/Printer Port

PLC Port

Aux Port

Power

Emergency Stop button – two NC contacts

Two 2-positions enabling switches – NO contacts

In all the most common configurations, the signals are wired to the cable and there will be no need to

open the unit to access the terminal blocks.

Note:  the ePALM10 unit does not include a current loop (20 mA) interface in the PLC port. The

communication modules TCM04 (Interbus), TCM07 (Simatic S7 MPI without optical

insulation), TCM08/TCM18 (Profibus DP) and TCM10/SCM11 (Ethernet) are not supported.

Internally to the product all signals, excluding emergency stop, are wired to a detachable interface

board with five terminal blocks.

The position of the terminal blocks and the numbering of the contacts are shown in the figure belo



  • MOTOROLA MVME172PA-652SE VME Embedded Controller
  • MOTOROLA FLN4234A ACE3600 CPU3680 Processor Module
  • Motorola MVME333-2 Controller Communications Module Specs
  • MOTOROLA MVME335 PCB California VME Module 0733500
  • EMERSON MOTOROLA MVME-147SRF / MVME147SRF MPU VME MODULE
  • MOTOROLA MVME705A Serial Transition Module
  • MOTOROLA MVME705B 6-Channel Serial Transition Module
  • MOTOROLA MVME712A MVME712AM I/O Transition Module
  • MOTOROLA MVME715P Rear Transition Module
  • MOTOROLA MVME172 VME Embedded Controller
  • MOTOROLA MVME2100 Series VME Processor Modules
  • MOTOROLA MVME5100 SeriesVME Processor Modules
  • SAMSUNG SSAS-PRO RSPC-X32 ALARM AND MONITORING SYSTEM MODULE
  • MOTOROLA TMCP700 W33378F High-Performance Industrial Computing Module
  • MOTOROLA VME Single Board Computer MVME188A
  • MOTOROLA MVME162PA-344 High-Performance Embedded VME Controller
  • MOTOROLA FAB 0340-1049 High-Efficiency Intelligent Embedded Module
  • MOTOROLA 30-W2960B01A High-Performance Industrial Interface Module
  • MOTOROLA MVME712M Transition Module.
  • MOTOROLA MVME5500 Series VME Single-Board
  • MOTOROLA MVME300 High-Reliability GPIB VMEbus Controller
  • MOTOROLA CPCI-6020TM High-Performance CompactPCI Transition Module
  • MOTOROLA MVME162-210 Embedded Controller
  • MOTOROLA MVME162-522A 01-W3960B/61C Embedded Controller
  • MOTOROLA MVME162-512A Embedded Controller
  • MOTOROLA MVME162-512 Embedded Controller
  • MOTOROLA MVME162-220 Embedded Controller
  • MOTOROLA MVME162-13 Embedded Controller
  • MOTOROLA MVME162-10 Embedded Controller
  • MOTOROLA MVME162-012 Embedded Controller
  • MOTOROLA MCP750 CompactPCI Host Slot Processor
  • Phoenix 2320267 QUINT-UPS/ 24DC/ 24DC/10/3.4AH - Uninterruptible power supply
  • Phoenix 2320267 QUINT-UPS/ 24DC/ 24DC/10/3.4AH - Uninterruptible power supply
  • Phoenix QUINT4-PS/3AC/24DC/40 - Power supply 2904623
  • Phoenix 2904622 QUINT4-PS/3AC/24DC/20 - Power supply
  • Phoenix 2905012 QUINT-PS/96-110DC/24DC/10/CO - DC/DC converter, protective coating
  • Phoenix 2905011 QUINT-PS/60-72DC/24DC/10/CO - DC/DC converter, protective coating
  • Phoenix 2904600 QUINT4-PS/1AC/24DC/5 - Power supply
  • Phoenix 2904603 QUINT4-PS/1AC/24DC/40 - Power supply
  • Phoenix 2904601 QUINT4-PS/1AC/24DC/10 - Power supply
  • Phoenix 2904602 QUINT4-PS/1AC/24DC/20 - Power supply
  • Phoenix QUINT-PS/60-72DC/24DC/10 - DC/DC converter 2905009
  • Phoenix QUINT-PS/96-110DC/24DC/10 - DC/DC converter 2905010
  • Phoenix QUINT-PS/3AC/24DC/20/CO - Power supply, with protective coating 2320924
  • Phoenix QUINT-PS/1AC/12DC/20 - Power supply 2866721
  • Phoenix 2320908 QUINT-PS/1AC/24DC/ 5/CO - Power supply, with protective coating
  • Phoenix 2866213 QUINT-BUFFER/24DC/20 - Buffer module
  • Phoenix 2866585 QUINT-DIODE/48DC/40 - Redundancy module, with protective coating
  • Phoenix 2320393 QUINT-BUFFER/24DC/24DC/40 - Buffer module
  • Phoenix 2320157 QUINT-DIODE/12-24DC/2X20/1X40 - Redundancy module
  • Phoenix 2907720 QUINT4-DIODE/48DC/2X20/1X40 - Redundancy module
  • Phoenix 2907719 QUINT4-DIODE/12-24DC/2X20/1X40 - Redundancy module
  • HONEYWELL FC-R/PB2/N/12 high-integrity field controller
  • Metso A419471 High-Performance Analog Output Module
  • ABB RED670 1MRK004810-AC Transmission line differential protection
  • Applied Materials (AMAT) 0190-19092 High-Performance RF Match Controller Board
  • ABB UFC789AE101 | 3BHE014023R0101 High-Performance AC 800PEC Control Unit
  • GE MIFIIPA55E20HI00 Multilin MIF II Digital Feeder Protection Relay
  • GE DS3815PAHB1A1A Speedtronic Mark IV Processor & Interface Board
  • GE DS3800NB1A Speedtronic Mark IV Power Supply / Regulator Board
  • GE DS3800HIOC Speedtronic Mark IV High-Level Input/Output Board
  • GE DS3800NHVG Speedtronic Mark IV High-Voltage Gate Driver Board
  • ABB 1TGE120011R1010 MC M117 KIT 24VDC CMMB+PTC
  • Woodward 5448-897 Current Differential Protection Relay
  • GE IS220PAOCH1BE Mark VIe Analog I/O Module
  • ABB Feeder Protection and Control REF620E_1G NBFNAAAAAABC6BBN11G
  • ABB UUD148AE02 | 3BHE014185R0002 High-Performance UNITROL Control Module
  • ABB MT-91-ARCFPA High-Precision Tension Control Interface Module
  • HIMA PS1000/230010 982200080 high-performance power supply module
  • HIMA H7202 Distribution Fuse Board / Infeed Board
  • HIMA F60DIO24/1601 Safety-Related Controller
  • HIMA F60DO801 Safety-Related Controller
  • HIMA H7201 Line fuse board
  • HIMA HIMatrix ELOP II 892042336 Version V5.6 Build 1501.9810 IV1
  • HIMA HIMatrix SILworX 504110 895400001
  • HIMA HIMatrix SILworX 504111 895210001
  • HIMA OPC DA Server 892042400 Version 3.56.4
  • HIMA OPC Alarm & Event Server (892042420) Version 4.1.3
  • HIMA OPC Alarm & Event Server (892042420) Version 4.0.5
  • Phoenix QUINT-DIODE/12-24DC/2x20/1x40 2320157 Redundancy module
  • Phoenix QUINT-PS/1AC/24DC/40 2866789 Power supply
  • Moore SIY/PRG/4-20MA/10-42DC SIY PC Programmable Signal Isolator and Converter
  • Motorola 01-W3394F-03F Communication Interface Module
  • Motorola AP-4 256 MByte 01-W3839F-07A Communication Module
  • MOTOROLA MVME2432 01-W3394F-03C VME Processor Module
  • MOTOROLA PCE I 01-W3839F-07A VME Processor Module
  • Motorola HPR431 / SYS431 / SYS443 / MFT543 Component Assembly
  • Motorola AP-4 01-W3394F-03G Communication Interface Module
  • Emerson 01-W3878F-02D DeltaV M-Series I/O Module
  • ICS Triplex Trusted T8232 Power Pack Module
  • ALFA LAVAL AAL7000 OXYGEN ANALYSER V0.1
  • Alstom MPM123 Measurement and Protection Module
  • Honeywell 05701-A-0361 Engineering Card
  • Honeywell 05701-A-0351 PLC Module
  • Honeywell 5701 CONTROL SYSTEM
  • KONGSBERG MRU-E-JB1 Host machine
  • Woodward easYgen-3200-1/P1 8440-2049
  • Woodward easYPROTEC-1410-7 8441-1161 8441-1160
  • Woodward MFR300-71M/K45 8444-1111 8444-1112
  • Woodward MFR300-75M 8444-1107 8444-1108 8444-1109
  • Woodward MFR300-71M/K42 8444-1104
  • Woodward MFR300 75M/SU03, Transducer 8444-1093 8444-1094 8444-1095
  • Woodward MFR300-71M 8444-1091 8444-1092
  • Woodward MFR300-15M 8444-1090 8444-1089
  • Woodward MFR300-11M 8444-1071 8440-1089
  • Woodward MFR500-6M/WK0400 + DPC USB 8444-1070
  • Woodward MFR300-15M 8444-1064
  • Woodward SPM-D2-1040B/NYB 8440-2189
  • Woodward SPM-D2-1010B/NYB 8440-2177
  • Woodward SPM-D2-10B/PSY5-FU-D 8440-2170
  • Woodward SPM-D2-1040B/XN analog speed/voltage bias 8440-2190
  • Woodward MFR300-71M 8444-1063
  • SPM-D2-1010B/X analog speed/voltage bias 8440-2168
  • Woodward SPM-D2-1040B/X analog speed/voltage bias 8440-2171
  • Woodward SPM-D2-1010B/N wide range power supply 8440-2174
  • Woodward SPM-D2-1040B/N wide range power supply 8440-2175
  • Woodward SPM-D2-1010B /110VAC sensing 8440-2166
  • Woodward SPM-D2-1040B /400VAC sensing 8440-2164
  • Woodward DTSC-200A 8440-2297
  • Woodward DTSC-200-55B/K38 8440-2155
  • Woodward DTSC-200-51B 8440-1867 8440-1868
  • Woodward 8445-1049 8445-1048 Converter, 1x FO to CAN
  • Woodward easYlite-200 8446-1007 LED Lamp Expansion Module
  • Woodward IKD-OUT-16 16 DO Expansion Card 8440-2306
  • Woodward IKD-IN-16 16 DI Expansion Card 8440-2307
  • Woodward IKD1M 8 DI/8 DO Expansion Card 8440-2116
  • Woodward easYview-07-30 8446-1071
  • Woodward easYFLEX-3400XT-P2 (GAP) 8440-2217