Graphical display 120x64 pixels (up to 8 lines

20 characters)

• Highly visible transflective LCD display

• 27-keys keypad with tactile feedback

• Connection to industrial bus systems

• Large memory size (512 KB Flash)

• IP65 protection

• Includes Emergency Stop button

• Includes enabling switches, normal or 3

positions

• Available in version for connection to Ethernet

and Profibus DP

The ePALM HMI panels are the handheld products of the UniOP family. All of the ePALM products

support the rich common functionality of the UniOP operator panels:

• Versions available for connection to

Ethernet and Profibus DP. Ethernet

version allows connection to field devices

as well as programming the HMI from

Designer.

• Powerful and intuitive programming with

the UniOP Designer 6 software

• Support of more than 130 communication

drivers for industrial devices

• Transflective LCD display ensures

readability under the most critical light

conditions

• Display dynamic data in numerical, text,

bargraph and graphic image formats

• Recipe data storage. Recipe data can be

transferred to a host computer using the

Ethernet connection.

• Multilanguage applications. The number

of runtime languages is limited only by the

available memory. All text information in

the application can be exported in Unicode

format for easier translation.

• Powerful macro editor to configure

keypad operation

• Alarms and historical alarm list. Alarm

and event information can be printed or

transferred to a host computer using the

Ethernet connection.

• Eight level password protection.

• Report printing to serial printer. Reports

are freely configurable using Designer.

• Ethernet-based UniNet network to share

data between UniOP HMIs and to serve

data using UniNet OPC Server.

In addition some unique features make the

ePALM10 a perfect fit for handheld operation.

• Emergency Stop button. Hardwired.

• Enabling switches. Hardwired.

• High-quality polyurethane cable for

mobile applications

Model Cable Type/Length PC/Printer Port PLC Port Module Enabling switches

ePALM10-0061 Serial/5m Yes Yes - two normal

ePALM10-0062 Serial/10m Yes Yes - two normal

ePALM10-3P61 Serial/5m Yes Yes - one 3-position

ePALM10-3P62 Serial/10m Yes Yes - one 3-position

ePALM10-0066 Ethernet/5m - - SCM11 one 3-position

ePALM10-0068 Ethernet/10m - - SCM11 one 3-position

ePALM10-0067 Profibus DP/10m Yes - TCM08 one 3-position

ePALM10-0069 Profibus DP/5m Yes - TCM08 one 3-position

Enabling switches are implemented in two different solutions in the various ePALM models:

Two independent 2-positions switches with NO contacts

One 3-positions switch with two NO contacts

The operator must operate the two independent 2-positions switches simultaneously. The two

normally open contacts are wired directly to the controller.

The 3-positions switch must be operated as described in the table.

Position Button status Contacts Function

1 Released Open Not enabled

2 Pressed Closed Enabled

3 Pressed completely Open Panic

The switch provides two normally open contacts to be wired directly to the controller.

3.2 Indicators and Keypad

The standard keypad of the ePALM panels is shown in the figure below.

Custom artwork may be designed and produced on request. Please inquire for more information.

Battery Replacement

A Lithium battery is required for data back-up. The battery maintains the following data:

• Hardware real time clock

• Event list

• Recipe data

Note:  replacing the battery will cause the loss of the data maintained by the battery.

To replace the battery follow the procedure listed below:

1) turn off the power to the device

2) using a screwdriver loose the 6 screws securing the plastic enclosure

3) open the handheld; the battery is located on the CPU subsystem

4) remove the battery

replace the battery with a new one

6) close the handheld and tighten the six screws

7) apply power to the handheld and check that the battery good status is reported.

The unit must always be grounded to protection earth (PE). Grounding helps limit the effects of noise

due to electromagnetic interference on the control system.

The power supply circuit may be floating or grounded. In the latter case connect to ground the power

source common as shown in figure 4 with a dashed line.

When using the floating power scheme, note that the panels internally connect the power common to

ground with a 1 M resistor in parallel with a 3.3 nF capacitor.

The power supply must have double or reinforced insulation

The suggested wiring for the power supply is shown in figure 4.

All the electronic devices in the control system must be properly grounded. Grounding must be

performed according to applicable regulations.

3.5 Applicable Regulations

Regulations and recommendations have been issued in Europe covering the main safety-related issues

in control systems, which include operator interfaces.

EN 60204-1 lists some important guidelines applicable when using operator interfaces.

9.2.4 Suspension of safeguards

9.2.5.3 Stop

9.2.5.4 Emergency stop

9.2.5.6 Hold-to-run controls

9.2.5.7 Two-hand controls

9.4 Control function in case of failure

Do not use operator interface to directly command motors, valves or other actuators not equipped with

safeguards and potentially harmful to persons or equipment in case of fault to the unit.

  • ADLINK 3U CompactPCI Blades CT-3620
  • ADLINK 3U CompactPCI Blades cPCI-3620
  • ADLINK 3U CompactPCI Blades cPCI-3620
  • ADLINK 3U CompactPCI Blades cPCI-3630
  • ADLINK 3U CompactPCI Blades cPCI-3640 Series
  • 3U CompactPCI Blades cPCI-3520 Series
  • ADLINK IMB-M42H ATX Motherboards
  • Adlink PCIe-GIE74 /PCIe-GIE74V Frame Grabbers / Video Capture Cards
  • ADLINK USB-1605 Removable screw terminal blocks or high-density D-Sub
  • Adlink ETX-NR667-L7400/LXE ETX Module
  • ADLINK NuPRO-842LV/P industrial control motherboard
  • ADLINK cPCI-8994 Serial Communication
  • ADLINK / PCI-7432 Digital I/O
  • ADLINK IEC-915GV Compact industrial-grade fanless embedded system
  • ADLINK ADLINK, PLX / PCI-7296 Digital I/O
  • ADLINK HPCI-14S12U 0040 Backplane Selection Guide
  • ADLINK MXE-5500 /MXE-5501/M16G (G) Fanless Embedded Computer
  • Adlink Multi-Function DAQ PCI-9112
  • ADLINK NuPRO-852LV Control Board
  • ADLINK CompactPCI cPCI-7432R Digital I/O Module
  • ADLINK NUPRO-E320LV PICMG Single Board Computers
  • ADLINK PICMG Single Board Computers NuPRO-E72
  • ADLINK PICMG Single Board Computers NuPRO-865
  • Vibro-Meter Rack VM600SYSMK2-ABE04x 6U 19-inch rack Mk2 system
  • Vibro-Meter Relay expansion RLC16 Mk2 SIL2 (single card) 600-044L
  • Vibro-Meter Relay expansion RLC16 Mk2 SIL2 600-04
  • Vibro-Meter Relay expansion RLC16 Mk2 600-045L
  • Vibro-Meter Relay expansion RLC16 Mk2 600-045
  • Vibro-Meter I/O interface card  IOCN Mk2    600-051
  • Vibro-Meter CPU controller   CPUM Mk2  600-050
  • Vibro-Meter I/O interface card    IOC10 Mk2 (rear card)    600-046
  • Vibro-Meter Temperature / Analog Acquisition  AMC10 Mk2  600-042
  • Vibro-Meter I/O interface card IOC4 Mk2 600-043
  • Vibro-Meter Protective measuring card MPC4 Mk2 SIL2 601-041-A10
  • Vibro-Meter Protective measuring card MPC4 Mk2 601-041-A0
  • Vibro-Meter PSU-VM600 VM600 Rack Power Module
  • Vibro-Meter ABE056 - 1U ultra-thin single-rack
  • Vibro-Meter ABE046 - 6U 19-inch rack
  • Vibro-Meter ABE045 - 6U 19-inch rack
  • Vibro-Meter ABE044 - 6U 19-inch rack (with expansion slots)
  • Vibro-Meter ABE042 6U 19-inch rack (4 slots)
  • Vibro-Meter I/O interface card XIO16T
  • Vibro-Meter XMC16 16-channel combustion monitoring card
  • Vibro-Meter XMV16 - 16-channel vibration condition monitoring card
  • Vibro-Meter RLC16 Relay Card
  • Vibro-Meter IRC4 Intelligent Relay Card
  • Vibro-Meter IOCR2 input/output rear interface card
  • Vibro-Meter CPUR2 Central Processing and Controller Card
  • Vibro-Meter I/O interface card  -  IOCR
  • VIBRO-METER CPU controller CPUR
  • VIBRO-METER IOCN 200-585-000-322 I/O interface card
  • VIBRO-METER IOCN 200-585-000-321 I/O Interface Card
  • VIBRO-METER 200-595-074-323 VM600 system CPU management card, non-redundant
  • VIBRO-METER CPUM 200-595-074-322 CPU Controller
  • VIBRO-METER CPU controller CPUM 200-595-070-321
  • Vibro-Meter IOC8T VM600 Mk1 I/O Interface Card
  • Vibro-Meter AMC8 Analog Monitoring Card
  • VIBRO-METER IOC4G2 I/O interface card
  • VIBRO-METER MPC4G2 Protective measuring card
  • VIBRO-METER IOC4T 200-560-101-017 VM600 Mk1 Isolated I/O Interface Card, equipped with MPC4
  • VIBRO-METER IOC4T 200-560-101-015 VM600 Mk1 interface card
  • VIBRO-METER IOC4T 200-560-000-114 I/O interface card
  • VIBRO-METER IOC4T 200-560-000-113 I/O interface card
  • VIBRO-METER IOC4T 200-560-000-111 Sensor wiring
  • VIBRO-METER MPC4 200-510-072-212 Protection Measurement Card
  • VIBRO-METER MPC4 200-510-071-114 Protective Measurement Card
  • VIBRO-METER 200-510-071-111 4-channel vibration protection + 2-speed channels
  • VIBRO-METER 200-510-070-111 4-channel vibration protection + 2-speed channels
  • ADLINK PICMG Single Board Computers NuPRO-E315
  • ADLINK High Speed Link (HSL) PCI-7853
  • ADLINK Digital I/O PCIe-7432
  • ADLINK Mini-ITX Embedded Boards AmITX-AL-I
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6860A
  • ADLINK NuPRO-900A PICMG Single Board Computers
  • ADLINK Analog Output PCI-6308 Series
  • ADLINK USB DAQ USB-2405
  • ADLINK CRR-LX800-E-500 Compact Industrial Computer Module (COM)
  • ADLINK 15-slot 6U PXI/CompactPCI Chassis with AC PXIS-3320
  • ADLINK NUPRO-842 PICMG Single Board Computers
  • ADLINK PCI-8124-C Advanced 4-CH Encoder Card
  • ADLINK PCI-8102 Centralized Motion Controllers PCI-8102
  • ADLINK PCIe-7200 High-Speed DIO
  • SEL SEL-7201 Feeder Protection Panel
  • SEL SEL-7206 Distribution Bus Differential Protection Panel
  • SEL SEL-4388 Mirrored Bits Tester
  • SEL SEL-T4287 Traveling-Wave Test System
  • SEL SEL-4000 Relay Test System
  • SEL SEL-9510 Control Switch Module
  • SEL SEL-9502 Contact Arc Suppressor
  • SEL SEL-9501 Contact Arc Suppressor
  • SEL SEL-2652 Trip Coil Monitor
  • SEL SEL-2894 Interface Converter
  • SEL SEL-2890 Ethernet Transceiver
  • SEL SEL-2886 EIA-232 to EIA-485 Interface Converter
  • SEL SEL-9220 Fiber-Optic Adapter for SEL-300 Series Relays
  • SEL SEL-2824 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2820 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2815 Fiber-Optic Transceiver/Modem
  • SEL SEL-2814 Fiber-Optic Transceivers With Hardware Flow Control
  • SEL SEL-2812 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2810 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2831 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2830 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2829 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-C805 200 µm Multimode Fiber-Optic Cable
  • SEL SEL-C804 Multimode Arc-Flash Detection Fiber-Optic Cables
  • SEL SEL-9331 Power Supply
  • SEL SEL-9322 15 VDC Power Supply
  • SEL SEL-9321 Low-Voltage DC Power Supply
  • SEL SEL-LPS Linear Power Supply
  • SEL SEL-RPM Redundant Power Module
  • SEL SEL-7250 Digital Direct-Replacement Assemblies
  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software