KONG -Y
NameDescriptionContent
Location:

Model 10959-201 and -203 Wall-Mount Audio Messenger Interfaces

From: | Author:kongjiang | Time :2025-04-30 | 922 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Confidentiality Notice

This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive business and technical information that is confidential and proprietary to GAI-Tronics.   GAI-Tronics retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics product or system.  This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.

Product Overview

The GAI-Tronics Audio Messenger Interface (AMI) tone/speech generator broadcasts live pages, telephone pages, pre-recorded alarm tones, pre-recorded speech messages, etc., for use in virtually any application.

Features

 Recorded alarm tones  Eight inputs and eight outputs upgradeable to 40 inputs and outputs  600-ohm, 1 Vrms audio output  CompactFlash® memory  AMI Configuration Tool (ACT) PC Software  Scheduled events  Day/Night modes  Live/recorded speech messages  Integration to Page/Party® systems

Options

 Telephone access  Integration to Page/Party® systems  Up to 40 user defined inputs and 40 user defined outputs  Audio routing to eight zones  AMI redundancy for system reliability  Integration to ADVANCE systems

Configurations

Alarms

The ACT tool includes pre-recorded tones suitable for almost any application.  The tones include typical emergency tones (i.e., a siren, slow whoop, etc.) and signaling or process tones (i.e., a gong, steady tone, etc.).  All of the tones and speech messages broadcast by the AMI are stored in MP3 file format.  For applications where a required tone is not supplied, any tone recorded or stored in an MP3 file format can be used with the AMI.

Inputs/Outputs

The AMI includes eight configurable inputs and outputs.  Typically, the inputs are configured to activate tones and/or speech messages, mute audio playback, or reset alarms.  The outputs are typically used to activate external signaling devices, interface to automated control systems or interface to paging system equipment. If the standard eight inputs and outputs are not sufficient for an application, an I/O Control Module can be added to the system.  The I/O control module provides an additional 32 inputs and 32 digital outputs expanding the total I/O to 40 each.

Timed Events

The AMI has the capability to perform several functions based on the time of day.  With the ACT software, events can be scheduled to occur at any interval (hourly, daily, weekly, monthly, etc.).

Optional Telephone Operation

The Telephone Interface has multiple operational modes.  The appropriate mode is configurable by the AMI Configuration Tool software application. The AMI can provide passcode-protected telephone access to the system. The AMI can be configured to allow telephone access only if the correct Remote Access Security Code is entered.  The remote access code is used to prevent unwanted callers from directly accessing the system.  If the system is configured to use a security code, callers are required to enter the correct code to gain access to the system.  Day and Night modes can have different security codes. The modes of operation are as follows: 

  Page/Party® - Delivers a live voice page (not pre-recorded) to the page line output.  The party line is held open following the page. 

  Record Page - Records a page, and delivers it to the page line output. 

  Mixed Mode - Records a page, delivers it to the page line output, and holds the party line open following the page. 

  Live Page Mode - Delivers a live voice page (not pre-recorded) to the page line output.  The party line is not open following the page. 

  Ring Mode – Does not deliver a page, but instead plays a configured message on the page line to signal the incoming call.  Manual/Disabled – The Telephone Interface does not automatically answer a phone call.  However, an input can be configured for “Manual Access” to allow an attendant to manually answer the phone, and transfer calls to a party line. The AMI can support two modes of operation: Day and Night Mode.  The day and night modes can be configured independently of each other. As an example of the Day and Night modes, day mode may be configured to allow callers the ability of paging and subsequent party line communications.  The night mode may be configured to play a tone over the paging system alerting personnel of an incoming call.  In this mode, the call can be answered at any Page/Party® station.

Page/Party® Operation

The Page/Party® operation allows for the AMI to play messages/alarms and connect phone calls to a Page/Party® system. The Page/Party® operation has the ability to generate the VLC tone during a message/alarm that gives Page/Party® stations a signal to change the volume of the message/alarm being played. When the AMI is interfaced to a Page/Party® system, the operation of the telephone interface is as described above, and includes all page modes.  The selected party line is hardwired in the system, and cannot be changed by the caller or the AMI configuration. In addition to the telephone operation described above, a user on the Page/Party® system can initiate a call by using Party Hot Dial.  When configured via the ACT tool, the AMI recognizes when a station goes off hook on the designated party line, and automatically dials the preprogrammed telephone number.  When the station goes on-hook, the call is terminated after the hang-up delay expires.

  • Hirschmann RS20-2400T1T1SDAE Industrial Managed Ethernet Switch
  • Hirschmann BELDEN EAGLE30-04022O6TT999SCCV9HSE3F
  • Hirschmann MM3-2FXS2/2TX MICE Media Module
  • Hirschmann RS20-1600M2M2SDAPHC08.0.05 Industrial Managed Switch
  • Hirschmann OZD Profi 12M G12-1300 PRO Fieldbus Repeater
  • Hirschmann SPIDER 4TX/1FX-ST EEC Industrial Ethernet Switch
  • Hirschmann MM2-2FXM3/2TX1 MICE Media Module
  • Hirschmann RS20-2400M2M2SDAPHC09.0.14 Industrial Switch
  • Hirschmann RS20-0400M2M2SDAEHC07.1.05 OpenRail Switch
  • Hirschmann OZD Profi 12M G12-EEC Fieldbus Repeater
  • HIRSCHMANN MDA422-1/2-3.5c-23/46 sensor
  • Hirschmann RS30-2402T1T1SDAUHC Managed Industrial Switch
  • Hirschmann OZD GENIUS G12 Industrial Switche
  • Hirschmann OZD 485 G12-1300 PRO Fieldbus Repeater
  • Hirschmann MM2-2FXM2 MICE Media Module
  • Hirschmann RS20-1600S2T1SDAUHC Managed Industrial Switch
  • Hirschmann MS20-0800SAAEHH04.2.04 MICE Switch
  • Hirschmann SPIDER 4TX/1FX EEC Unmanaged Industrial Switch
  • HIRSCHMANN MS4128-L3P EEC Managed Industrial Ethernet Switch
  • HIRSCHMANN RS20-0400M2T1SDAPHC08.0.01 Managed Switch
  • ETEL EA-S0M-400-40/80A-0000-00 AccurET Modular Power Supply
  • ETEL EA-B0I-0-0-0000-00 Backplane Interface Board
  • ETEL EA-P2M-400-15/40A-0000-00 Position Controller
  • ETEL EA-P2M-400-15/40A-0000-00 Position Controller
  • ETEL EA-P2M-400-15/40A-0000-00 Position Controller
  • ETEL EA-P2M-400-10/20A-0000-01 Position Controller
  • ETEL EA-P2M-400-5/10A-0100-01 Position Controller
  • ETEL EA-P2M-048-2.5/5A-0000-01: Modular Position Controller
  • ETEL EA-S0M-300-40/80A-0000-00 Power Supply Module
  • ETEL EA-P2M-300-07/15A-0100-01 Position Controller
  • ETEL EA-P2M-300-07/15A-0000-01 Modular Position Controller
  • ETEL EA-P2M-300-4/7.5A-0100-01 Overview
  • Basler Electric MOC2. Motor Operated Potentiometer
  • Basler Electric BE1-11 RTD Module, Resistance Temperature Detector
  • Basler Electric RDP-110C, Remote Display Panel
  • Basler Electric VRM-2020. Voltage Regulation Module
  • Basler Electric IDP-1500. Interactive Display Panel
  • Basler Electric AEM-2020. Analog Expansion Module
  • Basler Electric IDP-2020. Interactive Display Panel
  • Basler Electric CEM-2020. Contact Expansion Module
  • Basler Electric CEM-125. Contact Expansion Module
  • Basler Electric BE2000E, Digital Voltage Regulator
  • Basler Electric SMC-150. Synchronous Motor Controller
  • Basler Electric AVC125-10. Voltage Regulator
  • Basler Electric BE1-25. Sync-Check Relay
  • Basler Electric DGC-2020ES, Digital Genset Controller
  • ETEL EA-P2M-400-5/10A-0000-01 Position Controller
  • Basler Electric BE1-64F, Ground Fault Relay
  • Basler Electric BE1-79M, Multi Shot Reclosing Relay
  • Basler Electric BE1-81O/U, Digital Frequency Relay
  • Basler Electric BE1-87B, High Impedance Bus Differential Relay
  • Basler Electric BE1-79A, Reclosing Relay
  • Basler Electric BE1-27. BE1-59. BE1-27/59. Voltage Relay
  • Basler Electric SMC-250. Synchronous Motor Controller
  • Basler Electric SGC-250N, Synchronous Generator Controller
  • Basler Electric SGC-250. Synchronous Generator Controller
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric DECS-2100. Digital Excitation Control System
  • Basler Electric DECS-250E, Digital Excitation Control System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric DECS-250. Digital Excitation Control System
  • Basler Electric DECS-450. Digital Excitation Control System
  • Basler Electric DECS-150. Digital Excitation Control System
  • Basler Electric Basler Electric ES-49. Temperature Relay
  • Basler Electric ES-81O/U, ES-81O,ES-81U Overfrequency Relay
  • Basler Electric ES-74V, DC Voltage Sensing Relay
  • Basler Electric ES-27/59. Under/Overvoltage Relay
  • Basler Electric ES-27. Undervoltage Relay
  • Basler Electric ES-25. Sync-Check Relay
  • Basler Electric ES-47, ES-47N Phase Sequence Relay
  • Basler Electric ES-37.ES-37/51 Undercurrent Relay
  • Basler Electric ES-32. Reverse Power Relay
  • Basler Electric ES-32. Reverse Power Relay
  • Basler Electric ES-59. Overvoltage Relay
  • Basler Electric ES-55. Power Factor Relay
  • Basler Electric DGC-2020HD, Digital Genset Controller
  • Basler Electric BE1-FLEX, Protection, Automation, and Control System
  • Schneider GUTOR OC0935 Power Factor Sampling Board
  • Schneider GUTOR OC0922 Analog Signal Isolation Board
  • Schneider GUTOR OC0908 Battery Voltage Detection Board
  • Schneider GUTOR OC0947 Temperature / IGBT Sampling Board
  • Schneider GUTOR OP2601 Communication Expansion Board
  • Schneider Electric GUTOR OP2312 bypass control board
  • Schneider Electric GUTOR OP2130 Cooling Fan Monitoring & Control Board
  • Schneider Electric GUTOR OP2010 Battery Test Board / Battery Management Diagnostic Card
  • Schneider Electric GUTOR OP2552 Three-phase Power Connection Board Assembly
  • Schneider Electric GUTOR OP1922A Parallel Control Board / Load-Sharing Synchronization Module
  • Schneider Electric GUTOR OP6290B Inverter Feedback Acquisition Board / Signal Scaling Module
  • Schneider GUTOR OP6280 Basic Signal Board
  • Schneider Electric GUTOR OP2456 / OP2456B Main control board
  • Schneider Electric GUTOR OP2452 Power Plug-in Panel
  • Schneider Electric GUTOR OP2450 Parallel Communication Board
  • Schneider Electric GUTOR OP2406 Interface Fuse Monitoring Board
  • Schneider Electric GUTOR OC0919 High-Power Semiconductor Module
  • Schneider Electric GUTOR OP6281A System Logic Interface Board
  • Schneider Electric GUTOR OP6285A Power Signal Acquisition Board
  • Schneider Electric GUTOR OP2438 Fan Monitor & Drive Protection Board
  • Schneider Electric GUTOR OP2446 Main Control CPU Board
  • ROLLS-ROYCE CE05-00 Steering Gear Control Module
  • ROLLS-ROYCE MARINE AS-BRATTVAAG WRC1021A CONTROLLER CARD
  • ROLLS ROYCE DECK MACHINERY MPC-300-A7029099 TERMINAL CONTROLLER UNIT
  • ROLLS-ROYCE HELICON THRUSTER CONTROL PANEL LF90S-01-06
  • Rolls-Royce PCC1030C Panel Controller Card
  • Rolls-Royce RRDIO15 Remote Digital Input/Output Module
  • Rolls-Royce TDI-11 Pitch & Direction Indicator Module
  • Rolls-Royce CCN 01 CANman Controller Network Module
  • Rolls-Royce SLIO 01 CANman Controller Network Module
  • Rolls-Royce MPC-210 Winch & Propulsion Control Module
  • Rolls-Royce MTI-144 Engine Control Module
  • Rolls-Royce Tenfjord FB10-002 Steering Gear Module (E-4500-40-1)
  • ROLLS ROYCE MARINE AS CIRCUIT BOARD (PCB) RRAI016
  • Rolls-Royce Marine AS PIP6-1 Marine Controller
  • ROLLS-ROYCE MPC-300 STARTER CONTROL UNIT A7029099
  • Rolls-Royce Data Respons MPCF1-10.4" Maritime Panel Computer
  • ROLLS-ROYCE MARINE OLC-40009 PCB CARD
  • Rolls-Royce Marine Brattvaag WRC1021B Controller Board
  • ROLLS-ROYCE CCN 01 & ROLLS-ROYCE SLIO 02 CANMAN CONTROLLER NETWORK
  • ROLLS-ROYCE ATC-3-A7033172 AQUAMASTER TURNING CONTROLLER
  • ROLLS-ROYCE POSCON V.3 JOYSTICK MODULE 6459
  • Rolls-Royce Marine 389-496-00 Joystick Remote Control Panel 6799-W, 389-996-00
  • Rolls-Royce data respons 10.4'' Panel Computer 98H010A0000I/R10I53S
  • Rolls-Royce H1127.0101 Marine Controller 000068308
  • Rolls-Royce CU40-0106-50 Steering Gear Control Panel
  • Beckhoff Polaris CP7011-1002-0010 operator operator HMI display 30.5 cm
  • Beckhoff AM8052-0JH1-0000 Servomotor 10.7 Nm (M0), F5 (104 mm)
  • Beckhoff AM8052-0JH1-0000 Servomotor 10.7 Nm (M0), F5 (104 mm)
  • Beckhoff BX5100-0000 CANopen Bus Terminal Controller
  • Beckhoff CX9020-0115 PLC Module CX90200115