PQM II Power QualIty Meter

Power quality metering with waveform capture and

historical data logging

• Easy to program and use with keypad and large illuminated

40 character display

• Multiple communication ports for integration with DCS and

SCADA systems

aPPlICatIons

• Supports DNP 3.0 and Modbus protocols

• Digital and analog I/Os for control and alarms

• Voltage disturbance recording capability for electrical

sag and swell events.

• Metering of distribution feeders, transformers, generators,

capacitor banks and motors

• Medium and low voltage systems

Features

Features

• Commercial, industrial, utility

• Flexible control for demand load shedding, power factor, etc.

Monitoring and Metering

• Ia Ib Ic In

• Va Vb Vc Vab Vbc Vca

• V I unbalance

• True PF crest and K factor

• Hz W var VA

• Wh varh VAh W cost

• Demand: A W var VA

• Harmonic analysis through 63rd with THD and TIF

• Event recorder - 150 events

• Waveform capture

• Data logger -98.000 events

• Voltage Disturbance Recorder (VDR) -500 events

Communications

• Front RS232 serial port (1.200 to 19.200 bps)

• Two rear RS485 serial ports with ModBus and

DNP 3.0 protocol

• Ethernet connectivity provided by MultiNet

• EnerVistaTM software is provided for setup and

monitoring functions

• External dial-in modem capabilities

Protection & Control

• Load shedding

• Power factor control

• Pulse input totalizing

Introduction

GE Multilin has set a new standard in

metering technology with the introduction

of the PQM II.  This meter, designed on

the latest industry specifications, provides

accurate and reliable three-phase power

metering with an optional Ethernet and

fiber communications module in a small

and modern package. The PQM II  can

be used for a variety of applications

including metering of distribution feeders,

transformers, generators and motors.

robust Metering and Power Quality

Capabilities in one Package

Digital Metering

The PQM II is an ideal choice when

continuous monitoring of a three phase

system is required. It provides metering for

current, voltage, real and reactive power,

energy use, cost of power, power factor

and frequency. Waveform capture and

Voltage Disturbance Recorder continuously

monitors power quality. Programmable

setpoints and 4 assignable output relays

allow control functions to be added for

specific applications.

Communications Made easy

Integrate process, instrumentation

and electrical requirements in a plant

automation system by connecting PQM II

meters to a DCS or SCADA system. Meter

provides multiple communication ports that

can provide data simultaneously to multiple

masters such as SCADA, DCS, BMS etc.

Meter supports both ModBus and DNP 3.0

protocol. A computer running EnerVistaTM

software can change system setpoints,

monitor values, status and alarms.

Continuous monitoring minimizes process

downtime by immediately identifying

potential problems due to faults or

changes.

Industry leading software makes

setup simple

The PQM II comes complete with

EnerVistaTM GE Multilin's suite of software

tools for managing the entire lifecycle

implementation of the PQM II. EnerVistaTM

contains all of the tools for setting up and

configuring your PQM II in minutes via

RS232. RS485. external modem or Ethernet

LAN.

ethernet capability

With the optional Multinet module, users

can add Ethernet capability to their meter.

Multinet is an Ethernet communications

module that allows connection of up to 30

ModBus devices, providing ModBus TCP/IP

communications for these devices over

Ethernet. This allows connection to Fiber

Optic LAN and WAN systems for remote

access to data on the PQM II.

standard Features

The PQM II provides continuous monitoring

of a three-phase system. It provides

metering of current, voltage, real and

reactive power, energy use, cost of power,

power factor and  frequency. Ethernet

communications are available through the

optional Multinet module.

Metering

PQM II is a true RMS meter with 0.2%

accuracy for voltage and currents. The

PQM II provides advanced features for

monitoring and metering which include:

•    Ia        Ib            Ic            In

•    Va        Vb        Vc        Vab        Vbc        Vca

•    V    I    unbalance

•    True    PF    crest    and    K    factor

•    Hz    W    var    VA

•    Wh        varh        VAh        W    cost

•    Demand:    A        W        var    VA

Keypad and illuminated 40 character

dis play provides local setpoint settings and

monitoring of values and status.

Mounting Versatility

PQM II panel mount with display, offers an

easy local interface. Standard models have

RS485 communications for programming

and monitoring. Users can replace

expensive additional devices by-adding

the CONTROL, TRANS DUCER and POWER

analysis options to the PQM II as required.

alarms

Any of the assignable outputs may be

used to trigger an alarm for specific

applications. Simple alarm messages

provide easy notification

ConDItIon

aPPlICatIon

motors/transformers

pumps/compressors

leakage/unbalance

motors

overcurrent

undercurrent

neutral current

current unbalance

overvoltage

undervoltage

phase sequence

overfrequency

underfrequency

power factor

switch input

equipment protection

motors/load transfer

pumps/equipment

generators

load shedding

capacitor banks

process control

Communications

Integrate process, instrumentation

and electrical requirements in a plant

automation system by connecting PQM II

meters to a DCS or SCADA system. Initially

PQM II meters can be used as stand-alone

units. Open architecture allows connection

to other ModBus® compatible devices

on the same communication link. At a

later stage PQM II can be integrated in a

complete plant wide system for overall

process monitoring and control.

The standard PQM II comes complete

with a rear RS485 and front RS232 port.

RS232 port can be used for data collection,

printing reports or problem analysis without

disturbing the main RS485 communication

interface at rear. The standard meter

provides:

•    RS485    ModBus®    1.200    to    19.200‑bps

•    DNP    3.0    Level    2    Protocol

•    Mini    RTU    SCADA    system    component

•    Measure    actual    values

•    Read    status

•    Issue    control    commands

•    Load    all    setpoints    from    a    file

•    Change    individual    setpoints

A computer running EnerVistaTM software

can change system setpoints, monitor

values, status and alarms. Continuous

monitoring minimizes process downtime

by immediately identifying potential

problems due to faults or changes.

Future expansion

The PQM II uses non-volatile flash memory

for firmware storage. This allows future

product upgrades to be loaded via

the serial port. Upgrades can also be

downloaded from the GE Multilin website.

options

There are a variety of options available

to the user, allowing a range of custom

configurations:

transducer

Four analog outputs: Four isolated analog

outputs can be used to replace eight

analog transducers. Output signals can

be selected from any of the measured

parameters for direct interface to a PLC or

other devices.

analog Input: PQM II meter can accept

two analog inputs from external devices.

Meter can be programmed to activate a

control relay based on analog input from

transducers (temperature, level etc.)

Communications

second rear Comm Port: An additional

rear RS485 comm port is provided for

simultaneous monitoring by process,

instrument, electrical or maintenance

personnel.

Control

Three output relays and four inputs allow

measured parameters from the standard

PQM II to be combined with setpoints

and I/Os for control applications. With the

control option, three output relays and

four switch inputs are added along with

programmable set points to make

a mini RTU. Output relays can also be

controlled via the communication port or

assigned to different setpoints for custom

programming to accommodate many

applications such as:

•    Undercurrent    alarm    for    pumps

•    Over    and    undervoltage    for    generators

•    Unbalance    alarm    for    rotating    machines

•    Dual    level    power    factor    for    capacitor

bank switching

•    Underfrequency/demand    output    for

load shedding resulting in power cost

savings

•    kWh,    kvarh    and    kVAh    pulse    output    for

PLC interface

Power analysis

Data Logger (Trending): Trending is

useful as a trouble shooting aid when a

problem is detected. Measured values

can be selected and plotted with a

programmable sampling rate to suit the

time interval of interest. The generated

chart recorder screen can be printed or

exported to other programs for report

writing.

Harmonic analysis: Non linear loads such

as variable speed drives, computers and

electronic ballasts can cause harmonics

which may lead to problems such as

nuisance breaker tripping, telephone

interference, transformer, capacitor or

motor overheating. Harmonic analysis

can be used for fault diagnosis such as

detecting undersized neutral wiring, need

for a harmonic rated transformer, or

effectiveness of harmonic filters. Details

of the harmonic spectrum are useful and

available with the power analysis option.

Voltage Disturbance recorder (VDr)

Digital Metering

The Voltage Disturbance Recorder (VDR)

function adds to the PQM II the ability

to monitor and record Sag and Swell

disturbances. It can record up to

500 sag/swell events for all voltages

simultaneously.

enerVistaTM software

waveform Capture: Voltage and current

waveforms can be captured and displayed

on a PC using the EnerVistaTM program

supplied with the PQM II or using third

party software. Distorted peaks or notches

from SCR switching provide clues for taking

corrective action.

event recorder: Alarms, setpoint triggers,

input and output events can be stored

in a 150 event record and time and date

stamped by the internal clock. This is

useful for diagnosing problems and

system activity. Minimum and maximum

values are also continuously updated and

time stamped.

trace Memory: The PQM II can be

configured to record a maximum of 36

cycles of data on all voltage and current

inputs based on overvoltage, undervoltage,

overcurrent or switch input state change.

enerVistaTM launchpad

EnerVistaTM Launchpad is a powerful

software package that provides users with

all of the setup and support tools needed

for configuring and maintaining GE Multilin

Products.  Launchpad allows configuration

of devices in real-time by communicating

using RS232. RS485. Ethernet, or modem

connections.

The intuitive user interface makes it simple

to enter setpoints, read metered values,

monitor status and evaluate power quality.

Powerful troubleshooting features make it

easy to retrieve and view voltage & current

waveshapes and harmonic analysis.

This vital information can help provide

early warning of problems and prevent

equipment damage or nuisance breaker

tripping.

enerVista launchpad PQM II setup and analysis

PQM II setup program contains  many tools and reports that simplify device configuration and allows viewing of power system events.

Included in Launchpad is a document

archiving and management system

that ensures critical documentation  is

up-to-date and available when needed

by automatically checking for and

downloading new versions of manuals,

applications notes, specifications, and

service bulletins.

Viewpoint Monitoring

Viewpoint Monitoring is a simple-to

use, full-featured monitoring and data

recording software package for small

systems. Viewpoint Monitoring provides a

complete HMI package that instantly puts

critical real-time device data on your PC

through pre-configured graphical screens

with the following functionality.

•    Plug‑&‑Play    Device    Monitoring

•    System    Single‑Line    Monitoring    &

Control

•    Annunciator    Alarm    Screens

•    Trending    Reports

•    Automatic    Event    Retrieval

•    Automatic    Waveform    Retrieval

enerVistaTM Integrator

EnerVistaTM Integrator is a toolkit that

allows seamless integration of GE Multilin

devices into new or existing automation

systems by sending GE device data to

HMI, DCS, and SCADA systems. Included in

EnerVista Integrator is:

•    OPC/DDE    Server

•    GE    Multilin    Drivers

•    Automatic    Event    Retrieval

•    Automatic    Waveform    Retrieva




  • BECKHOFF CX5020-0122 Controller Module
  • Beckhoff CP3915-0000 Multitouch Panel
  • BECKHOFF EL3014 | EtherCAT Terminal
  • BECKHOFF Industrial Computer c6920-1057-0030
  • Beckhoff CX5130-0141/4GB CX5130-0141 Embedded PC
  • Beckhoff C6240-1052-0040 4-086-06-3073 Industrial Computer
  • Beckhoff CX5140-0135 /4GB High-Performance Embedded Industrial PC
  • Beckhoff C6515-1001-0000 Industrial PC
  • Beckhoff AX5103-0000-0200 - Digital Compact Servo Drives
  • Beckhoff CX2030-0130-1003/4GB Basic CPU module
  • Beckhoff AX8620-0000 Power Supply Module
  • Beckhoff CX9020-0111 module with
  • Beckhoff EL7332 PLC Module
  • BECKHOFF CP7709-0001-0020 HMI
  • Beckhoff CX5120-0155/2GB Embedded PC
  • BECKHOFF CP7037-1037-0010 OPERATOR INTERFACE TOUCHSCREEN
  • Beckhoff EK9000 | ModbusTCP/UDP Bus Coupler
  • Beckhoff Touch Panel Screen CP6020 -0000-0000
  • Beckhoff CX2020-0121 Module FAST Shipping
  • Beckhoff CX2030-0125 Basic CPU Module
  • Beckhoff CP3918-0000 Multi-Touch 18.5" Control Panel
  • Automotion LC4A00010 DC BL Motor Control, ATS, Sub Assy, SCP, 115VAC,
  • 500T-115VAC - VAS ENGINEERING - DORIC 500 SERIES DIGITAL TEMP INDICATOR
  • Honeywell X-DCS2000/EN Digital Integrated System Manager 50/60Hz 100-240V #4
  • Kollmorgen S60600 Servostar600 606-Fan 4 kVA, 6 A, 3 X 230 - 480 V
  • ABB XZ C828 A101 Didt Dioder Snubber 3BHE039453R0101
  • ABB 3BHB027232R0001 1-Phase Charging Transformer
  • ABB 3BHE006412R0101 Circuit Board UFC762AE101
  • ABB XVC770BE101 3BHE021083R0101 Circuit Board
  • ABB 3BHE021887R0101 UBCC717BE101 Board 3BHB002751R0102
  • ABB 3BHE032593R0001 Isolated Power Supply
  • ABB 3BSC610023R0001 POWER SUPPLY SD812
  • Beckhoff C6650-0060 | Control cabinet Industrial PC
  • Beckhoff CP2916-0000 Industrial HMI Display Panel
  • Beckhoff AM8053-0L2B-0000 Servomotor 15.4 Nm (M0), F5 (104 mm)
  • Beckhoff CP6202-0001-0020 Industrial Panel PC
  • Beckhoff CX2020-0120 Plc Module
  • Beckhoff CX1010-0111 BASIC CPU MODULE
  • Beckhoff C6017-0010 | Ultra-compact Industrial PC
  • BECKHOFF CX2040-0155 Plc Module
  • Beckhoff CX5120-0125 Embedded PC
  • BECKHOFF C6930-0040 INDUSTRIAL CONTROL COMPUTER
  • Beckhoff CP6907-0001-0000 Economy Built-in Control Panel
  • Beckhoff CP2912-0000 Multi-Touch Built-In Control Panel
  • Beckhoff C6015-0010 Ultra-Compact Industrial PC
  • Beckhoff CX5130 | Embedded PC with Intel Atom® E3827
  • Beckhoff C6030-0060 Ultra-Compact Industrial PC
  • OMRON 3G3XV-A2007 3G3XV-A2007-NEV2
  • Omron NJ1019000 NJ1 programable logic controller
  • OMRON C120-LK202-EV1/C120LK202EV1
  • OMRON C200H-AD003 PLC
  • OMRON C200H-CPU23-E COIL 24VDC PLC
  • Omron C200HG - C200H-ID212- C200H-OC226 C200HW-BC101 PLC Base Unit
  • OMRON C200H-OC222(Output Unit),C200H-PS211(Power Supply Unit),SP001 Module Rack
  • OMRON C200H-RT201 PROGRAMMABLE CONTROLLER
  • OMRON C200HS-CPU01-E SYSMAC PROGRAMMABLE CONTROLLER
  • OMRON C200H-SNT31 C200H Programmable Controllers
  • OMRON C200HW-MC402-E Motion control unit
  • OMRON C500-CT012 PLC
  • OMRON C500-NC103-E PLC
  • OMRON C500-NC222-E PLC
  • OMRON C500-PRW05-V1 PLC
  • OMRON C500-PRW06 PROGRAMMABLE CONTROLLER
  • OMRON C500-PS223-E 3G2A5-PS223-E PLC SYSMAC PROGRAMMABLE CONTROLLER
  • OMRON C500-TU001 3G2A5-TU001 PLC PLC
  • OMRON C60H-C1DR-DE-V1 Programmable Controllers
  • OMRON C60H-C5DR-DE-V1 Programmable Controllers
  • OMRON C60H-C6DR-DE-V1 Programmable Controllers
  • OMRON CJ1G-CPU44H CPU module
  • OMRON CJ1G-CPU45H PLC
  • OMRON CJ1M-CPU13-ETN V4.0 PLC PLC
  • OMRON CJ1W-AD041-V1 Analog input uni
  • Omron CJ1W-CORT21 PLC module
  • OMRON CJ1W-IDP01 Input unit
  • OMRON CJ1W-MCH71 - MECHATROLINK-II
  • OMRON CJ1W-MD261 Digital I/O
  • OMRON CJ1W-NC413 Position control unit
  • OMRON CJ1W-NCF71 Position Control Units
  • OMRON CJ1W-PTS51 Process Simulation I/O Module
  • OMRON CJ1W-PTS52 Process Simulation I/O Module
  • OMRON CJ1W-SCU21-V1 PLC
  • Omron CJ1W-SCU22 Serial Communication Unit
  • OMRON CJ1W-TC001 CJ Series Temperature Control Unit
  • Omron CK3W-AX1515N  Motion Controller
  • Omron CP1E-N60DR-D Compact PLC CPU
  • OMRON CP1E-NA20DT1-D PLC PLC
  • OMRON CP1H-X40DT-D plc PLC
  • OMRON CPM2C-S110C-DRT Interface module
  • OMRON CQM1-AD041 PLC
  • SAACKE F‑GDSA‑1 / F‑GDSA‑2 Feuerungsautomaten
  • SAACKE F-GDSA 143303 Controller SHIPS UPS
  • ICS Triplex T8270 Trusted 24 Vdc FanAssembly
  • SCHNEIDER M522220000 SA SM_DO16R 16 DIGITAL OUTPUTS MODULE
  • LENZ EPL10200-W EPZ-10203 CANPT010W3E
  • OMRON CQM1H-CPU61 PLC
  • OMRON CQM1H-MAB42 PLC
  • OMRON CS1G-CPU44-EV1 PLC
  • OMRON CS1G-CPU44H CPU
  • OMRON CS1H-CPU63-EV1 PLC
  • OMRON CS1H-CPU66-V1 PLC
  • OMRON CS1W-CLK13 PLC communication module
  • OMRON CS1W-EIP21 PLC
  • OMRON CS1W-MAD44 PLC PLC
  • OMRON CS1W-SCU31-V1 CVM1-BC103 PLC
  • Omron CVM1-CPU21-V2 CPU Unit
  • OMRON F150-C10E-2 Vision Controller
  • OMRON F150-C15E-3 Vision Controller
  • OMRON F160-C15E VISION MATE CONTROLLER
  • OMRON F500-C10-ETN F500-C15-ETN Vision Sensor
  • OMRON F500-VS F500-S1
  • OMRON FH-3050 FH Vision Controller
  • Omron FQ2-S25050F PLC Smart Camera
  • Omron FQM1-MMA22 Motion Module
  • OMRON GRT1-TS2P Temperature Module
  • OMRON H8PR-24 Cam Positioner
  • OMRON IDSC-C1DR-A-E Controller
  • OMRON K3HB-HTA-DRT1 Temperature Panel Meter
  • Omron KM-N1-FLK Power Detector
  • OMRON CJ1G-CPU43H CPU
  • OMRON NA5-7W001S-V1 NA5-9W001B-V1 NA5-12W101B-V1 Graphic panel
  • OMRON NA5-9W001B-V1 Graphic panel
  • OMRON NB10W-TW01B INTERACTIVE DISPLAY
  • OMRON NB7W-TW01B +CP1L-EL20DR-D Complete Power Panel
  • OMRON NB7W-TX01B INTERACTIVE DISPLAY PLC
  • Omron NE1A-SCPU02 Network Controller
  • OMRON  NA5-7W001B-V1 NA5-7W001S-V1 NA5-9W001B-V1 NA5-12W101B-V1 touch screen
  • Omron NS5-SQ00B-V2 NS5-SQ00-V2 NS5-SQ01-V2 NS5-SQ01B-V2 touch display panel
  • Omron NJ301-1100 Programmable Logic Controller