PQM II Power QualIty Meter

Power quality metering with waveform capture and

historical data logging

• Easy to program and use with keypad and large illuminated

40 character display

• Multiple communication ports for integration with DCS and

SCADA systems

aPPlICatIons

• Supports DNP 3.0 and Modbus protocols

• Digital and analog I/Os for control and alarms

• Voltage disturbance recording capability for electrical

sag and swell events.

• Metering of distribution feeders, transformers, generators,

capacitor banks and motors

• Medium and low voltage systems

Features

Features

• Commercial, industrial, utility

• Flexible control for demand load shedding, power factor, etc.

Monitoring and Metering

• Ia Ib Ic In

• Va Vb Vc Vab Vbc Vca

• V I unbalance

• True PF crest and K factor

• Hz W var VA

• Wh varh VAh W cost

• Demand: A W var VA

• Harmonic analysis through 63rd with THD and TIF

• Event recorder - 150 events

• Waveform capture

• Data logger -98.000 events

• Voltage Disturbance Recorder (VDR) -500 events

Communications

• Front RS232 serial port (1.200 to 19.200 bps)

• Two rear RS485 serial ports with ModBus and

DNP 3.0 protocol

• Ethernet connectivity provided by MultiNet

• EnerVistaTM software is provided for setup and

monitoring functions

• External dial-in modem capabilities

Protection & Control

• Load shedding

• Power factor control

• Pulse input totalizing

Introduction

GE Multilin has set a new standard in

metering technology with the introduction

of the PQM II.  This meter, designed on

the latest industry specifications, provides

accurate and reliable three-phase power

metering with an optional Ethernet and

fiber communications module in a small

and modern package. The PQM II  can

be used for a variety of applications

including metering of distribution feeders,

transformers, generators and motors.

robust Metering and Power Quality

Capabilities in one Package

Digital Metering

The PQM II is an ideal choice when

continuous monitoring of a three phase

system is required. It provides metering for

current, voltage, real and reactive power,

energy use, cost of power, power factor

and frequency. Waveform capture and

Voltage Disturbance Recorder continuously

monitors power quality. Programmable

setpoints and 4 assignable output relays

allow control functions to be added for

specific applications.

Communications Made easy

Integrate process, instrumentation

and electrical requirements in a plant

automation system by connecting PQM II

meters to a DCS or SCADA system. Meter

provides multiple communication ports that

can provide data simultaneously to multiple

masters such as SCADA, DCS, BMS etc.

Meter supports both ModBus and DNP 3.0

protocol. A computer running EnerVistaTM

software can change system setpoints,

monitor values, status and alarms.

Continuous monitoring minimizes process

downtime by immediately identifying

potential problems due to faults or

changes.

Industry leading software makes

setup simple

The PQM II comes complete with

EnerVistaTM GE Multilin's suite of software

tools for managing the entire lifecycle

implementation of the PQM II. EnerVistaTM

contains all of the tools for setting up and

configuring your PQM II in minutes via

RS232. RS485. external modem or Ethernet

LAN.

ethernet capability

With the optional Multinet module, users

can add Ethernet capability to their meter.

Multinet is an Ethernet communications

module that allows connection of up to 30

ModBus devices, providing ModBus TCP/IP

communications for these devices over

Ethernet. This allows connection to Fiber

Optic LAN and WAN systems for remote

access to data on the PQM II.

standard Features

The PQM II provides continuous monitoring

of a three-phase system. It provides

metering of current, voltage, real and

reactive power, energy use, cost of power,

power factor and  frequency. Ethernet

communications are available through the

optional Multinet module.

Metering

PQM II is a true RMS meter with 0.2%

accuracy for voltage and currents. The

PQM II provides advanced features for

monitoring and metering which include:

•    Ia        Ib            Ic            In

•    Va        Vb        Vc        Vab        Vbc        Vca

•    V    I    unbalance

•    True    PF    crest    and    K    factor

•    Hz    W    var    VA

•    Wh        varh        VAh        W    cost

•    Demand:    A        W        var    VA

Keypad and illuminated 40 character

dis play provides local setpoint settings and

monitoring of values and status.

Mounting Versatility

PQM II panel mount with display, offers an

  • CTI 2500-C200 CPU with 256K User Memory
  • CTI 2500-C100 CPU with 128K User Memory
  • CTI 2500P-J750 Janus PAC with 3MB Project Memory
  • Shinkawa WHF3006M Displacement Converter
  • Shinkawa JBP-220 (P-24-94A / P-24-94B) Circuit Board Module
  • SHINKAWA   WKN-142K5  2-WIRE VIBRATION TRANSDUCER
  • Shinkawa FRP-321 (P-26-54A / P-26-54B) Circuit Board Module
  • Shinkawa IOP-160 (P-25-72A / P-25-72B) Circuit Board Module
  • Shinkawa PK-147B-1 / PK-147A-1 Circuit Board Module
  • Shinkawa CPP-91A Circuit Board Module
  • Shinkawa FRP-177 PCB Module
  • Shinkawa CPP-127 (P-26-74A / P-26-74B) Circuit Board Module
  • Shinkawa FRP-227 (P-24-86A / P-24-86B) Circuit Board Module
  • Shinkawa MDP-104 (P-25-83A / P-25-83B) Circuit Board Controller
  • Shinkawa VK-143P2 High-precision eddy current sensor driver/signal conditioner
  • Shinkawa FRP-226 (P-24-86A / P-24-86B) Circuit Board Module
  • Shinkawa CPP-107A P-22-99A P-22-99B Circuit Board Module
  • SHINKAWA VW-202AL-8 Axial Displacement Sensor
  • Shinkawa VL-202A08L-1A42 Vibration Sensor Transducer Probe
  • Shinkawa FRP-209A & FRP-206 Wire Bonder Circuit Board Module
  • Shinkawa MGP-72 MGP72 P-26-50A P-26-50B Circuit Board Module
  • Shinkawa FRP-249 P-25-1A P-25-1B Circuit Board Module
  • Shinkawa FRP-320 P-26-54A P-26-54B Circuit Board Module
  • Shinkawa FRP-282 P-24-35A P-24-35B Circuit Board Module
  • Shinkawa FRP-338 P-26-54A P-26-54B Circuit Board Module
  • GE IS200AEPBH1B Pitch-Charger Control PCB Board
  • GE IS200EDEXG1ADA EX2100 SCR Trigger Control Board
  • GE 151X1207CK01SA01 IS200EDEXG1A EX2100 SCR
  • GE 151X1233DD02SA02 IS200AEPBH1B - Variant for pitch control charger assembly
  • GE 151X1233DB01SA01 IS200AEPBH1B - 10kW Wind Power Converter
  • GE 151X1233DB01SA01 IS200AEPBH1B - 10kW Wind Power Converter
  • GE 151X1233DB01SA01R | IS200AEPBH1B 10KW Converter
  • GE 151X1233DD01SA02 Pitch Battery Charger (109W6931P001)
  • GE 151X1233DD01SA02 Pitch Battery Charger Assy IS200AEPBH1B
  • GE 151X1233DB02SA02 Rev A IS200AEPBH1B Wind Turbine Converter
  • GE 151X1207CK02SA02 SCR 4400 V 1850 A IS200EDEXG1ADA General Electric EX2100
  • Triconex 3723X 32-Channel TMR Analog Input Module with HART
  • SHINKAWA VM-21G  SIGNAL CONDITIONER SOCKET
  • SHINKAWA VM-21R REVOLUTION SIGNAL CONDITIONER
  • SHINKAWA VM-21T DISPLACEMENT INPUT THRUST SIGNAL CONDITIONER
  • SHINKAWA VM-21D 6-WIRE LVDT SIGNAL CONDITIONER
  • SHINKAWA VM-21P 3-WIRE LVDT SIGNAL CONDITIONER
  • SHINKAWA VM-21A  VIBRATION SIGNAL CONDITIONER
  • SHINKAWA VM-21K DISPLACEMENT INPUT VIBRATION SIGNAL CONDITIONER
  • SHINKAWA VM-25S01 CONDITION MONITORING SYSTEM
  • SHINKAWA VM-25 CONDITION MONITORING SYSTEM
  • SHINKAWA VM-772B DEVICE CONFIG
  • SHINKAWA VM-771B MCL VIEW
  • SHINKAWA VM-76B INSTRUMENT RACK
  • SHINKAWA VM-75B POWER SUPPLY MODULE
  • SHINKAWA VM-742B NETWORK COMMUNICATION MODULE
  • SHINKAWA VM-741B LOCAL COMMUNICATION &  PHASE MARKER MODULE
  • SHINKAWA VM-722B 9-CHANNEL RELAY MODULE
  • SHINKAWA VM-707B AERODERIVATIVE GAS TURBINE  MONITOR MODULE
  • SHINKAWA VM-706B ROD DROP MONITOR MODULE
  • SHINKAWA VM-705B 18-CHANNEL TEMPERATURE   MONITOR MODULE
  • SHINKAWA VM-704B TEMPERATURE MONITOR MODULE
  • SHINKAWA VM-703B TACHOMETER & ECCENTRICITY  MONITOR MODULE
  • SHINKAWA VM-702B ABSOLUTE VIBRATION  MONITOR MODULE
  • SHINKAWA VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE
  • SHINKAWA MODEL VM-5X INTERFACE UNIT
  • SHINKAWA MODEL VM-5W2 DUAL POWER SUPPLY INSTRUMENT RACK
  • SHINKAWA MODEL VM-5H4  INSTRUMENT RACK (for VM-5Z5.6.7)
  • SHINKAWA MODEL VM-5G  SINGLE UNIT   INSTRUMENT RACK
  • SHINKAWA MODEL VM-5Z5,6,7  POWER SUPPLY UNIT
  • SHINKAWA MODEL VM-5Y1,2,3 RELAY MODULE UNIT
  • SHINKAWA MODEL VM-5P3 PHASE MARKER UNIT
  • SHINKAWA MODEL VM-53 DUAL COMMUNICATION UNIT
  • SHINKAWA MODEL VM-52 BOTTOM HOLD MONITOR
  • SHINKAWA MODEL VM-51 ROD DROP MONITOR
  • SHINKAWA MODEL VM-5R TACHOMETER
  • SHINKAWA MODEL VM-5S DUAL TACHOMETER
  • SHINKAWA MODEL VM-5A DUAL VALVE
  • SHINKAWA MODEL VM-5E DUAL CASE
  • SHINKAWA MODEL VM-5L COMPLEMENTARY INPUT
  • SHINKAWA MODEL VM-5N RAMP DIFFERENTIAL
  • SHINKAWA MODEL VM-5D DUAL DIFFERENTIAL
  • SHINKAWA MODEL VM-5T DUAL THRUST MONITOR
  • SHINKAWA MODEL VM-5C ECCENTRICITY MONITOR
  • SHINKAWA MODEL VM-5C ECCENTRICITY MONITOR
  • SHINKAWA MODEL VM-5M DUAL PATH MONITOR
  • SHINKAWA MODEL VM-5B DUAL ACCELERATION MONITOR
  • SHINKAWA MODEL VM-5B DUAL ACCELERATION MONITOR
  • SHINKAWA MODEL VM-5U DUAL SEISMIC MONITOR
  • SHINKAWA MODEL VM-55 VIBRATION MONITOR
  • SHINKAWA VM-742B1-5 VIBRATION MONITORING SYSTEM CARD
  • Shinkawa PSP-17B P-24-64A P-24-64B Circuit Board Module
  • SHINKAWA MGP-67 PCB
  • Shinkawa JBP-278 P-22-48A-1 P-22-48B-1 Circuit Board Module
  • Shinkawa VM-721B 18-CHANNEL RELAY MODULE
  • Shinkawa FRP-337 P-26-54A P-26-54B Circuit Board Module
  • Shinkawa WKN-142K2-2 Vibration Transmitter
  • SHINKAWA VL-202A08L-1012 Rotor Position Monitor Probe Sensor
  • Shinkawa CPP-128 P-26-74A P-26-74B Circuit Board Module
  • Honeywell 51402755-100 PROCESSOR CARD
  • Honeywell 51107595-100 Power
  • HONEYWELL 51304544-100 Control Board
  • HONEYWELL 51109919-100 BOARD
  • HHoneywell 51204160-175 Digital Input Module
  • Honeywell 51304754-150 High Level Analog Input Module
  • HONEYWELL 51304690-100 DIGITAL INPUT CARD
  • Honeywell 51401635-150  COMM CONTROL
  • HONEYWELL 51204174-175 MC-TAOY 52 ANALOG OUTPUT BOARD
  • HONEYWELL  51400596-100
  • HONEYWELL 51401291-100 board card
  • HONEYWELL 51401642-150 I/O LINK MODULE
  • Honeywell LCN‑E Hub Power Supply 38500148‑300
  • Honeywell LCN‑E Hub redundant 38500143‑202 Twisted‑pair LCN
  • Honeywell LCN‑E Hub non‑redundant,38500143‑102
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MX‑DTAC01K2
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MX‑DTAB01K2
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MT11‑520
  • Honeywell STI‑CE Smart Transmitter Interface 51304516‑150
  • Honeywell STI Smart Transmitter Interface 51304516‑100 MC‑PSTX02
  • Honeywell ulse Counter IOP 51304386‑100 MU‑PPIX02
  • Honeywell DO Digital Output IOP‑CE 51304487‑150 CE  version
  • Honeywell DO Digital Output IOP  51304487‑100 MC‑PDOX02
  • Honeywell TDC‑3000 SOE DI IOP,51402625-175 MC‑PDIS12
  • Honeywell TDC‑3000  DI Digital Input IOP‑CE 51304485‑150
  • Honeywell TDC‑3000 DI Digital Input IOP 51304485‑100 MC‑PDIX02
  • Honeywell TDC‑3000 AO Analog Output IOP 51304757‑100 MU‑PAOX02
  • Honeywell TDC‑3000  TC Thermocouple IOP 51304756‑100 MU‑TAMT03
  • Honeywell TDC‑3000   51304755‑100 MU‑TAMR03
  • Honeywell TDC‑3000 LLAI Multiplex AI IOP,51304362‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP‑CE, 51304363‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP,51304363‑100.4‑20mA
  • Honeywell TDC‑3000  HPM Power Supply,51401731‑100
  • Honeywell TDC‑3000 Standard 1986.HPM High‑Performance PM CPU,51402362‑100