HONEYWELL CC-PAOX01 High-Level Analog Output Module 16 Pt w/o Hart
In virtually all configurations, the C300 controller and Series C I/O provides useful, maintainable process equipment connections in a smaller footprint than existing competitors and Honeywell equivalent products. Installing Series C I/O modules contributes to overall total installed cost savings. IOTA sizes vary based on the application. In general, an analog module has 16 points and resides on a 6 inch (152mm) IOTA for non-redundant applications and a 12 inch (304mm) IOTA for redundant applications. A discrete module has 32 points and resides on a 9-inch (228mm) IOTA for non-redundant applications and a 12 inch (304mm) IOTA for redundant applications. Specific information on the size of a particular module is described in the Model Number Table.
• High Level Analog Input /HART Input Module (16pt) – The High Level Analog Input Module supports both high
level analog and HART inputs. Analog inputs are typically 4-20mA DC for both traditional and HART devices. HART
data can be used for status and configuration. HART data, such as the secondary and tertiary variables, can also be
used as process control variables. Two versions are available.
• High Level Analog Input w/o HART (16pt) - The High Level Analog Input Module supports high level analog inputs
Analog inputs are typically 4-20mA DC for traditional devices.
• Analog Output/HART Output Module (16pt) – The Analog Output Module supports both standard 4-20mA DC
outputs and HART transmitter outputs. Two versions are available.
• Analog Output w/o HART (16pt) – The Analog Output Module supports standard 4-20mA DC outputs.
• Digital Input 24 VDC (32pt) – Digital input sensing for 24V signals. Two versions are available.
• Digital Input High Voltage (32pt) – Digital input sensing for 110 VAC, 220 VAC, 125VDC.
• Digital Output 24 VDC (32 pt) – Current sourcing digital outputs. Outputs are electronically short-circuit protected.
Two versions are available.
• Relay Digital Output (32 pt) – Digital output with NO or NC dry contacts. Can be used for low power or high power
applications.
• Temperature Multiplexer (64 pt) – Provides thermocouple (TC) and resistance temperature device (RTD) inputs.
The Multiplexer supports up to four, field proven PMIO FTAs.
• Temperature Multiplexer (64 pt) – Provides thermocouple (TC) and resistance temperature device (RTD) inputs.
The Multiplexer supports up to four, field proven PMIO FTAs
• Pulse Input (8pt) – Provide linear counting, PV generation, and Quaduature Input for Custody Transfer
• Universal Input Output (32 pt) - Supports 32 channels of user configurable IO. Choices available – analog input,
analog output, digital input, and digital output.
Specifications Specifications for Series-C I/O modules are shown below. For information on environmental specifications, please refer to the Series-C Platform Specification and Technical data sheet EP03-520-xxx. 5.1. Analog Input with HART – CC-PAIH01 / 02 Function The Analog Input Module accepts high level current or voltage inputs from transmitters and sensing devices. Notable Features • Extensive self-diagnostics • Optional redundancy • Open Wire Detection • Supplies non-incendive field power • Non-incendive Power • HART-capable, multivariable instruments and multiple modems for fast collection of control variables • Fast loop scan • PV protection through an open wire detection diagnostic • Open-wire Bad PV Detection