GE Fanuc IC800SSI228RD2 servo electric controller

From: | Author:kongjiang | Time :2024-09-30 | 484 Browse: | 🔊 Click to read aloud ❚❚ | Share:

GE Fanuc IC800SSI228RD2 servo electric controller

This upgrade resolves a few issues.

• With S2K firmware revision 2.4 and prior, if the value in AIB1 (Analog Input Deadband1) waschanged, it changed the value in CCB (Cam Compile Begin point) and vice versa. This was dueto the fact that, internally,these registers were set to the same RAM address. Firmware revision2.5 resolves this problem by mapping these registers to their appropriate addresses.

• An issue existed in S2K firmware revision 2.4 and prior involving the use of dual loop positionmode. If the polarity of the main encoder feedback was opposite of the auxiliary encoder, thendual loop mode (PFE=1 andPFN>0) would be unstable, resulting in a following error fault onany move. This was due to the fact that the DIR register controlled the polarity of both theauxiliary and main encoder feedback paths in dual loopmode. The DIRX register was added toresolve this issue.

• In extremely noisy environments, false drive over-temperature faults were encountered. TheDrive Over-Temperature fault now has a software filter (1 second) on all models to eliminate thepossibility of noisetransients affecting the drive over temperature circuit.Behavioral ChangesAside from the new registers (URB, FRC, DIRX, DIRXN) the following behavioral changes must be

noted:

• Dual Loop Position Mode (PFE=1, PFN>0)In Revision 2.4 dual loop mode, DIR controlled the polarity of both the auxiliary encoder andmain encoder feedback paths (before entering the control loop summingjunction). In revision 2.5dual loop mode, DIR controls the polarity of the auxiliary feedback path while DIRX controls thedirection of the main encoder feedback path.

• CMR updateIn revision 2.4 encoder feedback S2Ks, the CMR register was used to specify certainmotor/encoder combinations. For instance, setting CMR=1 would configure the S2K tocommutate GE Fanuc S-Seriesmotors. Firmware revision 2.5 (with the addition of the FRCregister) now offers a more universal solution for commutating encoder based motors. Below is adescription of the revamped CMR:

With encoder based controllers, this register must be set to the number of motor pole pairs(firmware revision 2.5 and later).

Note: To run GE Fanuc S-Series motors, the CMR value must be set to 1, which is thecontroller default and the value set by the Motion Developer wizard. Setting CMR=1will automatically set FRC=10000 (firmwarerevision 2.5 and later). The CMR registercan be set automatically with the MOTORSET command (see MOTORSET descriptionfor procedure).


• MOTORSET Procedural Change

For encoder feedback S2Ks, the MOTORSET procedure has changed to the following: If using amotor with an encoder, the following steps are required to correctly determine the CMO andCMR of a motor.

1. Initialize RegistersSet KL and CURC accordinglySet FR and FRC to the feedback resolution of the encoderSet CMR to a value other than 1 (from 2 to 16)Execute a SAVE command

2. Determine CMRCycle the powerTurn the motor shaft at least a ¼ of a revolutionExecute a MOTORSET commandNow CMR is computed, but CMO may be incorrectExecute a SAVE command (thus saving CMR)

3. Determine The Correct CMOCycle the powerTurn the motor shaft at least a ¼ of a revolutionExecute a MOTORSET commandCMO is now computed correctlyExecute a SAVE command (saving CMO)



  • SAMSUNG SSAS-PRO SPTB-AI dedicated analog input terminal board
  • SAMSUNG SSAS-PRO SPTB-DO dedicated digital output terminal board
  • SAMSUNG SSAS-PRO SPTB-DI dedicated terminal board
  • SAMSUNG SSAS-PRO SPBK-X32-12 Heavy-duty 8-slot system chassis backplane
  • SAMSUNG SSAS-PRO SPBK-X32-08 Heavy-duty 8-slot system chassis backplane
  • SAMSUNG SSAS-PRO SPSU-X32 heavy-duty rack-mounted
  • SAMSUNG SSAS-PRO SPIRU-16 versatile universal mixed I/O module
  • SAMSUNG SSAS-PRO SPRI-16 RTD Temperature Input Module
  • SAMSUNG SSAS-PRO SPAO-8 Analog Output Module
  • SAMSUNG SSAS-PRO SPAI-16 Analog Input Module
  • SAMSUNG SSAS-PRO SPRDO-16 Relay digital output module
  • SAMSUNG SSAS-PRO SPDO-16 (Transistor Digital Output Module)
  • SAMSUNG SSAS-PRO SPDI-24 high-density digital input module
  • SAMSUNG SPDI-16 (Digital Input Module)
  • ADLINK 3U Enclosures & Systems AD-3100
  • Power Supplies cPS-H300S/AC ADLINK
  • CPCI Serial Peripheral cPCI-A3H10 ADLINK
  • ADLINK CPCI Serial Peripheral cPCI-A3XMC
  • CPCI Serial Peripheral cPCI-A3H20 ADLINK
  • CPCI Serial Peripheral cPCI-A3MXM ADLINK
  • ADLINK CPCI Serial Peripheral cPCI-A3COM
  • ADLINK CPCI Serial Peripheral cPCI-A3USB
  • ADLINK CPCI Serial Peripheral cPCI-A3ETH
  • CPCI Serial Peripheral cPCI-A3CAN ADLINK
  • 3U CompactPCI Serial Blades cPCI-A3525 Series
  • 3U CompactPCI Serial Blades cPCI-A3535 Series ADLINK
  • CompactPCI Backplanes cBP-6402 ADLINK
  • ADLINK CompactPCI Backplanes cBP-6402R
  • ADLINK CompactPCI Backplanes cBP-6105R
  • CompactPCI Backplanes cBP-6405R ADLINK
  • CompactPCI Backplanes cBP-6108F ADLINK
  • CompactPCI Backplanes cBP-6108R ADLINK
  • CompactPCI Backplanes cBP-6014R ADLINK
  • ADLINK 6U Enclosures & Systems cPCIS-6130R
  • ADLINK 6U Enclosures & Systems cPCIS-6230R/ 6240R Series
  • ADLINK 6U Enclosures & Systems cPCIS-6235R
  • ADLINK 6U Enclosures & Systems cPCIS-6400X Series
  • ADLINK 6U Enclosures & Systems cPCIS-6400U Series
  • ADLINK 6U Enclosures & Systems cPCIS-6418U
  • ADLINK 6U Enclosures & Systems cPCIS-3300BLS
  • ADLINK 6U Enclosures & Systems cPCIS-3320/AC
  • ADLINK Power Supplies cPS-H640/AC
  • ADLINK Power Supplies cPS-H640/48
  • ADLINK 6U Rear Transition Modules cPCI-R6100 Series
  • ADLINK 6U Rear Transition Modules cPCI-R6002 Series
  • ADLINK 6U Rear Transition Modules cPCI-R6600 Series
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6660
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6636(KL) Series
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6640 Series
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6540 Series
  • ADLINK CompactPCI Backplanes cBP-3064
  • ADLINK CompactPCI Backplanes cBP-3213PR
  • ADLINK 3U Enclosures & Systems cPCIS-2500 Series
  • ADLINK 3U Enclosures & Systems cPCIS-2630 Series
  • ADLINK 3U Enclosures & Systems cPCIS-2632 Series
  • ADLINK 3U Enclosures & Systems cPCIS-2642 Series
  • ADLINK U Enclosures & Systems cPCIS-2633 Series
  • ADLINK U Enclosures & Systems cPCIS-ET1100 Series
  • ADLINK Power Supplies cPS-H325/AC
  • ADLINK Power Supplies cPS-H325/48
  • ADLINK Power Supplies cPS-H325/110
  • ADLINK Power Supplies cPS-H325/24
  • ADLINK PCI-7841/cPCI-7841 Dual-port Isolated CAN Interface Cards
  • ADLINK Peripherals & Accessories cPCI-3548
  • ADLINK Peripherals & Accessories cPCI-8301
  • ADLINK Peripherals & Accessories cPCI-3W10
  • ADLINK Analog Output cPCI-6208/6216 Series
  • ADLINK Multi-Function DAQ cPCI-9116
  • ADLINK 3U CompactPCI Blades CT-3620
  • ADLINK 3U CompactPCI Blades cPCI-3620
  • ADLINK 3U CompactPCI Blades cPCI-3620
  • ADLINK 3U CompactPCI Blades cPCI-3630
  • ADLINK 3U CompactPCI Blades cPCI-3640 Series
  • 3U CompactPCI Blades cPCI-3520 Series
  • ADLINK IMB-M42H ATX Motherboards
  • Adlink PCIe-GIE74 /PCIe-GIE74V Frame Grabbers / Video Capture Cards
  • ADLINK USB-1605 Removable screw terminal blocks or high-density D-Sub
  • Adlink ETX-NR667-L7400/LXE ETX Module
  • ADLINK NuPRO-842LV/P industrial control motherboard
  • ADLINK cPCI-8994 Serial Communication
  • ADLINK / PCI-7432 Digital I/O
  • ADLINK IEC-915GV Compact industrial-grade fanless embedded system
  • ADLINK ADLINK, PLX / PCI-7296 Digital I/O
  • ADLINK HPCI-14S12U 0040 Backplane Selection Guide
  • ADLINK MXE-5500 /MXE-5501/M16G (G) Fanless Embedded Computer
  • Adlink Multi-Function DAQ PCI-9112
  • ADLINK NuPRO-852LV Control Board
  • ADLINK CompactPCI cPCI-7432R Digital I/O Module
  • ADLINK NUPRO-E320LV PICMG Single Board Computers
  • ADLINK PICMG Single Board Computers NuPRO-E72
  • ADLINK PICMG Single Board Computers NuPRO-865
  • Vibro-Meter Rack VM600SYSMK2-ABE04x 6U 19-inch rack Mk2 system
  • Vibro-Meter Relay expansion RLC16 Mk2 SIL2 (single card) 600-044L
  • Vibro-Meter Relay expansion RLC16 Mk2 SIL2 600-04
  • Vibro-Meter Relay expansion RLC16 Mk2 600-045L
  • Vibro-Meter Relay expansion RLC16 Mk2 600-045
  • Vibro-Meter I/O interface card  IOCN Mk2    600-051
  • Vibro-Meter CPU controller   CPUM Mk2  600-050
  • Vibro-Meter I/O interface card    IOC10 Mk2 (rear card)    600-046
  • Vibro-Meter Temperature / Analog Acquisition  AMC10 Mk2  600-042
  • Vibro-Meter I/O interface card IOC4 Mk2 600-043
  • Vibro-Meter Protective measuring card MPC4 Mk2 SIL2 601-041-A10
  • Vibro-Meter Protective measuring card MPC4 Mk2 601-041-A0
  • Vibro-Meter PSU-VM600 VM600 Rack Power Module
  • Vibro-Meter ABE056 - 1U ultra-thin single-rack
  • Vibro-Meter ABE046 - 6U 19-inch rack
  • Vibro-Meter ABE045 - 6U 19-inch rack
  • Vibro-Meter ABE044 - 6U 19-inch rack (with expansion slots)
  • Vibro-Meter ABE042 6U 19-inch rack (4 slots)
  • Vibro-Meter I/O interface card XIO16T
  • Vibro-Meter XMC16 16-channel combustion monitoring card
  • Vibro-Meter XMV16 - 16-channel vibration condition monitoring card
  • Vibro-Meter RLC16 Relay Card
  • Vibro-Meter IRC4 Intelligent Relay Card
  • Vibro-Meter IOCR2 input/output rear interface card
  • Vibro-Meter CPUR2 Central Processing and Controller Card
  • Vibro-Meter I/O interface card  -  IOCR
  • VIBRO-METER CPU controller CPUR
  • VIBRO-METER IOCN 200-585-000-322 I/O interface card
  • VIBRO-METER IOCN 200-585-000-321 I/O Interface Card
  • VIBRO-METER 200-595-074-323 VM600 system CPU management card, non-redundant
  • VIBRO-METER CPUM 200-595-074-322 CPU Controller
  • VIBRO-METER CPU controller CPUM 200-595-070-321
  • Vibro-Meter IOC8T VM600 Mk1 I/O Interface Card
  • Vibro-Meter AMC8 Analog Monitoring Card
  • VIBRO-METER IOC4G2 I/O interface card
  • VIBRO-METER MPC4G2 Protective measuring card
  • VIBRO-METER IOC4T 200-560-101-017 VM600 Mk1 Isolated I/O Interface Card, equipped with MPC4