Signal conditioner
FEATURES
» From the Vibro-Meter ® product line
» For CAxxx piezoelectric accelerometers
and CPxxx dynamic pressure sensors
» Configurable high-pass and low-pass filters
» Frequency range: 0.5 Hz to 20 kHz
» Optional integrator to produce a velocity output
» Optional 2-wire current or 3-wire voltage
transmission
» Certified for use in potentially explosive
atmospheres
» A range of installation options are available
DESCRIPTION
The IPC704 signal conditioner converts the chargebased signal from a piezoelectric-based transducer into a current or a voltage signal. This current or voltage signal is transmitted to the processing electronics via a standard 2-wire or 3-wire transmission cable. The current modulation technique allows transmission over a distance of up to 1 km. A GSI galvanic separation unit is required for this configuration.
The electronic circuitry of the IPC704 signal conditioner is incorporated into a moulded aluminium enclosure. The signal conditioner has configurable high-pass and low-pass filters and an optional integrator to give a velocity output. Furthermore, RFI filters protect the input and output against radiofrequency interference and other electromagnetic influences.
A range of installation options are available for the IPC704 signal conditioner, including:
» A polyester enclosure providing environmental protection against dust, oil and water jets.
» A mounting adaptor allowing the IPC704 signal conditioner to be mounted on a DIN rail
DESCRIPTION (continued)
Two versions of the IPC704 signal conditioner are available:
» An IPC704 for sensors using standard piezoelectric materials, for example, CAxxx, CP10x and CP2xx (ordering number 244-704-000-042-... )
» An IPC704 for sensors using GaPO4 piezoelectric material, for example, CP50x (ordering number 244-704-000-511-... ).
* Not engraved on the product marking.
For specific parameters of the mode of protection concerned and special conditions for safe use, refer to the certificates that are available from Meggitt SA on demand. When using protection mode ‘nA’ (non-sparking apparatus), the user shall ensure that the signal conditioner is installed in an enclosure that ensures a protection rating of at least IP54 (or equivalent). For the most recent information on the Ex certifications that are applicable to this product, refer to the Ex product register (PL-1511) document that is available from Meggitt SA. Industrial housing (ordering option G1) Available in Ex approved versions for use in hazardous locations
• Environment : II 2 G (Zones 1, 2) Ex e II < 109 Ω (DIN 53482)
• Surface resistivity for Ex version : Stuffing glands Available in Ex approved versions for use in hazardous locations
• Environment : II 2 G/D (Zones 1, 2) Ex e II For specific parameters of the mode of protection concerned and special conditions for safe use, refer to the certificates that are available from Meggitt SA on demand. For the most recent information on the Ex certifications that are applicable to this product, refer to the Ex product register (PL-1511) document that is available from Meggitt SA.
Add: Building F05, High-tech Software Park, Xiamen City, Fujian Province
Tel: 0592-5211302
Mobile: 17750019513 (WhatsApp)
Email: yy4291644@gmail.com
ivy@kongjiangauto.com