KONG -Y
NameDescriptionContent
Location:

Hirschmann MM20-P9P9P9P9SAHH In installation instructions

From: | Author:kongjiang | Time :2025-04-16 | 604 Browse: | 🔊 Click to read aloud ❚❚ ▶ | Share:

Important information 

 Note: Read these instructions carefully, and familiarize yourself with the device before trying to install, operate, or maintain it. The following notes may appear throughout this documentation or on the device. These notes warn of potential hazards or call attention to information that clarifies or simplifies a procedure.  Symbol explanation This is a general warning symbol. This symbol alerts you to potential personal injury hazards. Observe all safety notes that follow this symbol to avoid possible injury or death. If this symbol is displayed in addition to a safety instruction of the type “Danger” or “Warning”, it means that there is a danger of electric shock and failure to observe the instructions will inevitably result in injury. This symbol indicates the danger of hot surfaces on the device. In connection with safety instructions, non-observance of the instructions will inevitably result in injuries.

Safety instructions

UNCONTROLLED MACHINE ACTIONS To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices individually. Before you start any machine which is controlled via data transmission, be sure to complete the configuration of all data transmission devices. Failure to follow these instructions can result in death, serious injury, or equipment damage

Certified usage 

  Use the device solely for the application cases described in the Hirschmann product information, including this manual. Operate the device solely according to the technical specifications. 

  Supply voltage The devices are designed for operation with Safety Extra-low Voltage (SELV). Connect only SELV circuits with voltage restrictions according to IEC 60950-1 or ES1 according to IEC/EN 62368-1 to the supply voltage connections and to the signal contacts. The supply voltage is electrically isolated from the housing. 

  Use undamaged parts. 

  For power supply via DC voltage: All following prerequisites are fulfilled: 

  There are fuses suitable for DC voltage in the positive conductors of the supply lines, or the voltage sources are appropriately current limited. Regarding the properties of this fuse: See “General technical data” on page 67. 

  The negative conductors of the voltage inputs are on ground potential. 

  For power supply via AC voltage: All following prerequisites are fulfilled: 

  There are fuses in the supply lines, or the voltage sources are appropriately current-limited. Regarding the properties of this fuse: See “General technical data” on page 67. 

  The power sources are electrically isolated from the ground

  Relevant for North America: The device may only be connected to a Class 2 supply voltage that fulfills the requirements of the National Electrical Code, Table 11(b). If the voltage is being supplied redundantly (two different voltage sources), the combined supply voltages must fulfill the requirements of the National Electrical Code, Table 11(b). 

  Relevant for North America: For use in Class 2 circuits. Only use copper wire/conductors of class 1, 75 °C (167 °F). Start connecting the electrical wires only if all the above safety requirements are fulfilled

Use in Hazardous Locations

Relevant for North America for modules certified for Hazardous Locations: This equipment is suitable for use in Class 1, Division 2, Groups A, B, C and D or Non-Hazardous (unclassified) locations only. Make sure that peripheral devices are suitable for the application environment. The wiring for the voltage supply and for the inputs and outputs (I/O) must adhere to the wiring regulations for Class 1, Division 2 [article 501(b) of the National Electrical Code (USA), NFPA 70] and to the applicable statutory regulations. Note: Observe the control drawing (document number 000160011DNR) on the following pages. Avertissement - Risque d'explosion - Ne pas débrancher tant que le circuit est sous tension à moins que l'emplacement soit connu pour ne contenir aucune concentration de gaz inflammable. Avertissement - Risque d'explosion - La substitution de tout composant peut rendre ce matériel incompatible pour une utilisation en classe I, division 2


  • Beckhoff FC9002 | Ethernet card, 2 channels, PCI
  • Beckhoff FC7502 | Sercos II master card, 2 channels, PCI™
  • Beckhoff FC7501 | Sercos II master card, 1 channel, PCI™
  • Beckhoff FC5322 | CAN FD card, 2 channels, PCIe® x1
  • Beckhoff FC5321 | CAN FD card, 1 channel, PCIe® x1
  • Beckhoff FC5202 | DeviceNet®, master/slave card, 2 channels, PCI™
  • Beckhoff FC5201 | DeviceNet® master/slave card, 1 channel, PCI™
  • Beckhoff FC5122 | CANopen master/slave card, 2 channels, PCIe® x1
  • Beckhoff FC5121 | CANopen master/slave card, 1 channel, PCIe® x1
  • Beckhoff FC5102 | CANopen master/slave card, 2 channels, PCI™
  • Beckhoff FC5101 | CANopen master/slave card, 1 channel, PCI™
  • Beckhoff FC3122 | PROFIBUS master/slave card, 2 channels, PCIe® x1
  • Beckhoff FC3121 | PROFIBUS master/slave card, 1 channel, PCIe® x1
  • Beckhoff FC3102 | PROFIBUS master/slave card, 2 channels, PCI™
  • Beckhoff FC3101 | PROFIBUS master/slave card, 1 channel, PCI™
  • Beckhoff FC1428 | EtherCAT G master card, 8 channels, PCIe® x4
  • Beckhoff FC1121 | EtherCAT slave card, 1 channel, PCIe® x1
  • Beckhoff FC1100 | EtherCAT slave card, 1 channel, PCI™
  • Beckhoff FC1028 | EtherCAT master card, 16 channels, PCIe® x4
  • Beckhoff FC9062 | Gigabit Ethernet PCIe® module, 2-channel
  • Beckhoff C9900-R266 | NOVRAM PCIe® module
  • Beckhoff FC3161 | PROFIBUS master/slave PCIe® module, 1 channel
  • Beckhoff C9900-E301 | RS232 PCIe® module, 2 channels
  • Beckhoff C9900-E277 | USB 3.0 PCIe® module, 2 channels
  • Beckhoff C9900-E276 | PCIe® module for CP-Link 4 – The Two Cable Display Link
  • Beckhoff C9900-E271 | USB Extender 2.0 Tx PCIe® module, 1 channel
  • Beckhoff CU8803-000x | Transmitter box for CP-Link 4 – The One Cable Display Link
  • Beckhoff CU8802-000x | Transmitter box for CP-Link-4 – The Two Cable Display Link
  • Beckhoff CU8851 | USB extension, USB Extended 2.0 receiver box
  • Beckhoff CU8801-0000 | USB extension, USB Extended 2.0 transmitter box
  • Beckhoff CU8880-0010 | Ethernet controller with USB input
  • Beckhoff CU8871 | USB CFast slot
  • Beckhoff CU8870 | USB CompactFlash® slot
  • Beckhoff CU8815 | DVI splitter
  • Beckhoff CU8810-0010 | DVI splitter with USB extender
  • Beckhoff CU8006 | 4-port USB 3.0 hub
  • Beckhoff C9900-U332-0010 | Battery pack
  • Beckhoff C9900-U330 | Battery pack
  • Beckhoff C6670-0010 | Control cabinet industrial server
  • Beckhoff C6670-0020 | Control cabinet industrial server
  • Beckhoff C6240-0070 | Control cabinet Industrial PC
  • Beckhoff C6240-0080 | Control cabinet Industrial PC
  • Beckhoff C6675-0060 | Control cabinet Industrial PC
  • Beckhoff C6675-0070 | Control cabinet Industrial PC
  • Beckhoff C6650-0050 | Control cabinet Industrial PC
  • Beckhoff C6650-0070 | Control cabinet Industrial PC
  • Beckhoff C6640-0060 | Control cabinet Industrial PC
  • Beckhoff C6640-0070 | Control cabinet Industrial PC
  • Beckhoff C5210-0030 | 19-inch slide-in Industrial PC
  • Beckhoff C5210-0040 | 19-inch slide-in Industrial PC
  • Beckhoff C5210-0050 | 19-inch slide-in Industrial PC
  • Beckhoff C5240-0010 | 19-inch slide-in Industrial PC
  • Beckhoff C5240-0030 | 19-inch slide-in Industrial PC
  • Beckhoff C7015-0020 | Ultra-compact Industrial PC in IP65
  • Beckhoff C7015-0020 | Ultra-compact Industrial PC in IP65
  • Beckhoff C7015-0030 | Ultra-compact Industrial PC in IP65
  • Beckhoff C6525-0060 | Fanless built-in Industrial PC
  • Beckhoff C6525-0070 | Fanless built-in Industrial PC
  • Beckhoff C6525-0080 | Fanless built-in Industrial PC
  • Beckhoff C6515-0060 | Fanless built-in Industrial PC
  • Beckhoff C6515-0070 | Fanless built-in Industrial PC
  • Beckhoff C6515-0080 | Fanless built-in Industrial PC
  • Beckhoff C6043-0090 | Ultra-compact Industrial PC with NVIDIA® GPU
  • Beckhoff C6040-0090 | Ultra-compact Industrial PC
  • Beckhoff C6032-0060 | Ultra-compact Industrial PC
  • Beckhoff C6032-0070 | Ultra-compact Industrial PC
  • Beckhoff C6032-0080 | Ultra-compact Industrial PC
  • Beckhoff C6030-0070 | Ultra-compact Industrial PC
  • Beckhoff C6030-0080 | Ultra-compact Industrial PC
  • Beckhoff C6027-0000 | Fanless ultra-compact Industrial PC
  • Beckhoff C6027-0010 | Fanless ultra-compact Industrial PC
  • Beckhoff C6025-0000 | Fanless ultra-compact Industrial PC
  • Beckhoff C6025-0010 | Fanless ultra-compact Industrial PC
  • Beckhoff C6025-0020 | Fanless ultra-compact Industrial PC
  • Beckhoff C6930-0060 | Control cabinet Industrial PC
  • Beckhoff C6930-0070 | Control cabinet Industrial PC
  • Beckhoff C6930-0080 | Control cabinet Industrial PC
  • Beckhoff C6925-0030 | Fanless control cabinet Industrial PC
  • Beckhoff C6925-0040 | Fanless control cabinet Industrial PC
  • Beckhoff C6915-0010 | Fanless control cabinet Industrial PC
  • Beckhoff C6915-0020 | Fanless control cabinet Industrial PC
  • Beckhoff C6905-0010 | Economy control cabinet Industrial PC
  • Beckhoff C6905-0020 Economy control cabinet Industrial PC
  • Beckhoff C6905-0030 Economy control cabinet Industrial PC
  • Eaton SPN6084LEAXX2F Power Defense SB
  • Eaton MPNC4N3LEAXXSW Magnum low voltage power circuit breaker
  • EatonSP N8403YEAXX2H Power Defense SB
  • Eaton MPS8604WEAXX2C Magnum low voltage power circuit breaker
  • Eaton MPS8404WEAXXSW Magnum low voltage power circuit breaker
  • Eaton MPN6504LEAXX3A
  • Eaton MPSC323VEAXX2A Magnum low voltage power circuit breaker
  • Eaton SPS6304WEAXX2F Power Defense SB
  • Eaton MPN6504LEAXX2H Magnum low voltage power circuit breaker
  • Eaton MPSC504HEAXX2H Magnum low voltage power circuit breake
  • Eaton SPN85N3LEAXX2F Power Defense SB
  • Eaton SPN6403CEAXX2F Power Defense SB
  • Eaton MPSC5N4MEAXX3A Power Defense SB
  • Eaton SPSC124WEAXX2A Power Defense SB
  • Eaton SPS85A4WEAXX2H Power Defense SB
  • Eaton SPSC5N4MEAXX2A Power Defense SB
  • Eaton MPN8403VEAXX2H Magnum low voltage power circuit breaker
  • NZMB2-4-A200 MCCB NZM, NZM2 TM and Elec
  • Eaton NZMN1-A63 Series NZM complete molded case circuit breaker
  • Eaton NZMB1-S26-CNA Series NZM complete molded case circuit breaker
  • Eaton NZMH2-A25-NA Series NZM complete molded case circuit breaker
  • NZMH2-A200-BT-NA Eaton Series NZM complete molded case circuit breaker
  • NZMN4-VEF1200-NA Eaton Series NZM complete molded case circuit breaker
  • NZMH2-AF250-NA MCCB NZM, NZM2 TM and Elec
  • NZMB1-AF60-NA Eaton Series NZM complete molded case circuit breaker
  • NZMN1-A50 Eaton Series NZM complete molded case circuit breaker
  • NZMH2-A80-NA Eaton Series NZM complete molded case circuit breaker
  • Eaton Cutler-Hammer HFD3030 6639C86G87 3 Pole 30A 600V Circuit Breaker
  • Moeller XV-230-57CNN-1-13-1 HMI PLC Panel Touchscreen 5.7"
  • EATON CEAG CU CG-S , 40071360300 Control Unit
  • EATON SDN90186 MOTOR CONTROL CENTER
  • EATON HMCP150U4 CIRCUIT BREAKER
  • Eaton 7801C57 Digitrip Optimizer Hand Held Programmer
  • Eaton HMCP400R5 Circuit Breaker
  • EATON MP-3000 SAFETY RELAY 66D2032GX1
  • EATON PGGLOBL1701DPRO 1785T Touch Panel
  • Eaton, Moeller, Easy MFD-CP8-NT
  • Eaton WL-35717F Vacuum Interrupter
  • EATON VICKERS EEA-PAM-535-A-32 AMPLIFIER CARD
  • EATON FP5000-00 / FP5200-00 66D2041G11 FEEDER PROTECTION RELAY
  • Eaton IQ-504 120VAC Modular Overload Relay
  • Beckhoff CX5620-0225    CPU module
  • Beckhoff CX5620-0220    CPU module
  • Beckhoff CX5620-0215    CPU module, Beckhoff RT Linux®