KONG -Y
NameDescriptionContent
Location:

Motorola MVME162 Embedded Controller

From:MOTOROLA | Author:kongjiang | Time :2026-03-20 | 870 Browse: | 🔊 Click to read aloud ❚❚ | Share:

MVME162  Embedded Controller

Features of the MVME162 include:

25MHz 32-bit Microprocessor: either an MC68LC040 Enhanced 32-bit

Microprocessor with 8KB of cache and MMU, or an optional 25MHz

MC68040 32-bit Microprocessor with 8KB of cache, MMU, and FPU

1MB, 4MB, or 8MB of shared Dynamic Random Access Memory (DRAM)

with programmable parity

512KB of Static Random Access Memory (SRAM) with battery backup

One JEDEC standard 32-pin PLCC EPROM socket (EPROMs may be

shipped separately from the MVME162)

1MB Flash memory: either one Intel 28F008SA (for older boards) or four

Intel 28F020s (for newer boards)

Four 32-bit programmable timers and programmable Watchdog Timer

(MCchip)

Two 32-bit programmable timers and programmable Watchdog Timer

(optional VMEchip2)

8K by 8 Non-Volatile Random Access Memory (NVRAM) and Time of

Day (TOD) clock with battery backup (Thompson MK48T08)

Input/Output– Two serial ports (one EIA-232-D DCE; one EIA-232-D or EIA-530

DCE/DTE) – Serial port controller (Zilog Z85230)– Optional Small Computer Systems Interface (SCSI) bus interface with

32-bit local bus burst Direct Memory Access (DMA) (NCR 53C710

controller)– Optional LAN Ethernet transceiver interface with 32-bit local bus

DMA (Intel 82596CA controller)– Four MVIP IndustryPack interfaces

VMEbus interface (VMEchip2)—non-VMEbus version optional– VMEbus system controller functions– VMEbus interface to local bus (A24/A32. D8/D16/D32

(D8/D16/D32/D64BLT) (BLT = Block Transfer)– Local bus to VMEbus interface (A16/A24/A32. D8/D16/D32)– VMEbus interrupte

VMEbus interrupt handler– Global CSR for interprocessor communications– DMA for fast local memory-VMEbus transfers (A16/A24/A32.

D16/D32[D16/D32/D64BLT])

Switches and Light-Emitting Diodes (LEDs)– Two pushbutton switches (ABORT and RESET)– Eight LEDs (FAIL, STAT, RUN, SCON, LAN, FUSE, SCSI, and VME)

Specifications

Table 1-2. MVME162 Specifications, lists the specifications for an MVME162

without IndustryPacks. The subsequent sections detail cooling requirements

and FCC compliance.

Cooling Requirements

The Motorola MVME162 Embedded Controller is specified, designed, and

tested to operate reliably with an incoming air temperature range from 0° to

55° C (32° to 131° F) with forced air cooling at a velocity typically achievable

by using a 100 CFM axial fan.  Temperature qualification is performed in a

standard Motorola VMEsystem 3000 chassis.  Twenty-five watt load boards

are inserted in two card slots, one on each side, adjacent to the board under

test, to simulate a high power density system configuration.  An assembly of

three axial fans, rated at 100 CFM per fan, is placed directly under the VME

card cage.  The incoming air temperature is measured between the fan

assembly and the card cage, where the incoming airstream first encounters the

controller under test.  Test software is executed as the controller is subjected to

ambient temperature variations.  Case temperatures of critical, high power

density integrated circuits are monitored to ensure component vendors

specifications are not exceeded.

While the exact amount of airflow required for cooling depends on the

ambient air temperature and the type, number, and location of boards and

other heat sources, adequate cooling can usually  be achieved with 10 CFM

and 490 LFM flowing over the controller.  Less airflow is required to cool the

controller in environments having lower maximum ambients.  Under more

favorable thermal conditions, it may be possible to operate the controller

reliably at higher than 55° C with increased airflow.  It is important to note that

there are several factors, in addition to the rated CFM of the air mover, which

determine the actual volume and speed of air flowing over the controller.

Special Considerations for Elevated Temperature Operation

The following information is for users whose applications for the MVME162

may subject it to high temperatures.

The MVME162 uses commercial grade devices.  Therefore, it can operate in an

environment with ambient air temperatures from 0° C to 70° C.  Several factors

influence the ambient temperature seen by components on the MVME162.

Among them are inlet air temperature; air flow characteristics; number, types,

and locations of IndustryPack (IP) modules; power dissipation of adjacent

boards in the system, etc.

A temperature profile of the MVME162-023 was developed in an MVME945

12-slot VME chassis.  This board was loaded with one GreenSpring IP-Dual

P/T module (position a) and three GreenSpring IP-488 modules (positions b,

c, and d).  One twenty-five-watt load board was installed adjacent to each side

of the board under test.  The exit air velocity was approximately 200 LFM

between the MVME162 and the IP-Dual P/T module.  Under these conditions,

a 10° C rise between the inlet and exit air was observed.  At 70° C exit air

temperature (60° C inlet air), the junction temperatures of devices on the

MVME162 were calculated (from the measured case temperatures) and did

not exceed 100° C.

The following are some steps that the user can take to help make elevated

temperature operation possible:

1. Position the MVME162 board in the chassis for maximum airflow over the

  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • ADLINK SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO  HSL-4XMO-TB-D103  HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • ADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840
  • Adlink PICMG Single Board Computers NuPRO-935A
  • ADLINK ADLINK NuPRO-841 REV:1.0 PICMG Single Board Computers
  • ADLINK PCI-8254 / PCI-8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NUPRO-780 PICMG Single Board Computers
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • Adlink Technology 51-37111-0C1 cPCI-R8217 cPCI-R3700A PCB Interface Card
  • ADLINK DPAC-3020-11(G) Embedded PC Automation Controller
  • ADLINK NuPRO-840 PICMG 1.0 industrial Single Board
  • Adlink 6U CompactPCI 2.0 Blades cPCI-6965
  • ADLINK PCI-9114DG Multi-Function DAQ Card
  • Adlink NuPRO-E43 PICMG Single Board Computers
  • Adlink PCI-7856 Distributed Motion Control
  • ADLINK Mini-ITX Embedded Boards MI-965
  • ADLINK NuPRO-E340 ICMG Single Board Computers
  • ADLINK NuPRO-595 Series Full-Size PICMG 1.0 SBC
  • ADLINK PCIe-GIE64+ / PCIe-GIE62+ 4 / 2-CH PCI Express® Power over Ethernet Frame Grabbers
  • ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC