Emerson Ovation controller model OCR1100

Features Safe and reliable mission-critical control provides "interference-free" automatic failover between redundant controllers. One-step data acquisition function of fast processor to improve productivity, defined by I/O database, has small floor space, low power consumption, and no fan to operate with Ovation and WDPF I/O interfaces, and an integrated virtual I/O function Ethernet protocol system for third-party OEMs through Ovation and digital bus integrated interface I/O modules locally and remotely. Non-volatile storage of application software, integration of point database, configuration information and operation tuning constant, event sequence ability and 1 millisecond resolution meet IEC 61131-3 standard Achilles level 1 certification. Emerson's Ovation distributed control system is famous for providing accurate control. This accuracy begins with the safety of Ovation controller and key tasks such as power generation, water supply and wastewater treatment plants. OCR1100 model of Ovation controller series implements simple or complex modulation and sequence control strategy, data acquisition function of Ovation, interface network and various I/O subsystems. It can generate as many as 32,000 points. The process application Ovation OCR1100 controller is designed to meet all kinds of demanding requirements to process applications. The function controllers executed by include: continuous (PID) control Boolean logic advanced control special logic and timing function data acquisition event processing sequence cold junction compensation.

Process point sensor/limit inspection process point alarm processing process point is converted into engineering unit process point database to store local and remote input/output interface process point listing standard function control execution Ovation OCR1100 controller, using Intel-based processor, can simultaneously execute up to five process control tasks at cycle speed ranging from 10 milliseconds to 300 seconds. Each control task consists of I/O process point input scanning, control scheme execution and output scanning. For Ovation 3.6 and earlier, two control tasks use predefined cycle speeds of one second and 100 milliseconds. The other three control tasks can have a user-selectable cycle speed. Ovation 3.7 software version has a user-selectable loop speed ranging from 10 milliseconds to 300 seconds for all five control tasks. Control scheme OCR1100 functions are defined by the control table from a large number of standard and advanced Ovation algorithms designed for the power, water and wastewater treatment industries. The control table provides the basis for execution, recording and automatically creating the tuning diagram used during control debugging, and when adjusting the control scheme. On average, OCC100 controller can execute more than 1,000 control tables. The complete event sequence processing ability is to use Ovation I/O and standard controller to provide software. The resolution is 1 millisecond, and the event sequence subsystem records the sequence, in which a set of user-defined digital inputs indicate the change of state, providing valuable troubleshooting and diagnostic tools for high-speed electrical systems. In addition to the higher resolution time stamp, the event sequence point can be used to control the same scheme as any other I/O point, including limit check and alarm. The alarm processing OCR1100 processes the limit value and the database definition of each process point of alarm based on the following factors. Whether scanning the points input into the control loop or separating the data acquisition from the control function. The alarm status of each point in the controller is updated every scan. This state may indicate whether the point value has: out of sensor range exceeds user-defined limit; state change exceeds incremental limit; alarm report may be delayed on a per-point basis for a user-specified period of time. When used in combination with workstations, Ovation OCR1100 controller can report six independent alarm thresholds, which are defined as: four upper limits, user-defined upper limits, maximum plus incremental limits, and four lower limits, user-defined lower limits, minimum plus incremental limits. Workstations can classify alarms according to the following contents and display alarm importance levels selected by users. Operator interface processing Ovation controller performs all restrictions and alarms based on database configuration. However, Ovation HMI provides the following functions to suspend the flow status or operator operation of these functions as required.

Controller Type Ovation The function of the controller can be extended to additional software licenses for simulation and virtual control or advanced control. Simulator controller is a standard controller, which uses analog I/O instead of actual hardware I/O system to model or simulate the control scheme and process. The simulator controller can be a basic factory acceptance test flow model or a high fidelity factory model. The algorithm licensed by the advanced controller has advanced functions such as automatic regression, dynamic matrix, equipment, soot blowing, fuzzy logic, time sequence control, programmable module and temperature profile. Virtual controller is a software licensed function, which uses a real-time operating system platform based on Windows. It is mainly used for Ovation simulation, and the solution with non-redundant virtual controller can reduce the hardware space. Virtual controller has most standard interface properties, and it is supported by analog or advanced controller input and output except hardware. The OCR1100 controller is designed to adapt to the multi-level redundancy of key components, including: Ovation network interface function processor, memory and network controller processor power I/O interface input feed input/output power auxiliary power remote input/output communication media controller's standard hardware configuration redundancy is a passive backplane, and both of them are based on it to install the main controller and the standby controller. Redundant 24V power supply is connected to the device and distributed to the controller respectively. Each controller consists of two modules. A module provides the processor, memory, Ovation network and additional network connections. Other modules provide local and remote interfaces Ovation and Q Line I/O, plus internal power supply. Each functional processor in a redundant pair executes the same application program, although it is only an access I/O and runs in control mode for a period of time. Partner processors are running in backup, configuration or offline mode, the difference is that they are alert. Control Mode In the control mode, the main processor has the functions of direct input and output access, reading, writing, data acquisition and control. In addition, the primary processor monitors the status and health of its backups, partners' processors and networks. Backup mode In backup mode, the backup processor performs diagnosis and monitors the status and health of the primary processor. The backup processor maintains the latest data database memory of the control processor by polling and receives all the information sent by the control processor, including process point values, algorithm adjustment constants and variable point attributes. Automatic failover control The redundant function controller of Ovation OCR1100 is equipped with automatic failover control. If the processor in control mode fails, the watchdog detection circuit disables the I/O interface processor of the master device and will fail. The backup processor immediately starts to execute the process control application and broadcasts information through Ovation network. Ovation controller uses continuous control process memory update to keep the control and backup processors synchronized. This allows the algorithm to track output values, pass information upstream and apply data during the first execution.

  • GE ALSTOM TI PTrack Inductor Panel - Rail Inductor Panel
  • GE ALSTOM CH-1EC5 Chassis - Computer System Frame
  • GE ALSTOM BP-2 Backplane (Endbox Terminal Box)
  • GE ALSTOM BP-1 Backplane (Colorlight / Repeater Cabinet)
  • GE ALSTOM CI-1 Case Information Board
  • GE ALSTOM CDU-1 Control Display Unit
  • GE ALSTOM VPM-3 Vital Peripheral Master CPU
  • GE ALSTOM VPM-2 Vital Peripheral Master CPU
  • GE ALSTOM CPS-1 Central Power Supply - Power Supply Board
  • GE ALSTOM CIO-1 Communication I/O Communication Interface Board
  • GE ALSTOM UCI-3 Communication Module
  • GE ALSTOM VLO-C6S Vital Lamp Output - Lamp Output Board
  • GE ALSTOM VIO-1010S Vital I/O 10 Input 10 Output Card
  • GE ALSTOM VIO-44S Vital I/O 4-In 4-Out Board Card
  • GE ALSTOM VLD-C6S Vital Lamp Driver - Signal Light Driver Board
  • GE ALSTOM VTI-2S Vital Track Interface - Track Interface Board
  • GE MVDL800-57931101-A, 800A liquid-cooled Delta power module
  • GE MVDL800-47931101-A, 800A liquid-cooled Delta power module
  • GE MVDL800-57931001-A, 800A liquid-cooled Delta power module
  • GE MVDL800-47931001-A, 800A liquid-cooled Delta power module
  • GE MVDL800-5704-93-A, 800A liquid-cooled Delta power module
  • GE MVDL800-4704-93-A, 800A liquid-cooled Delta power module
  • GE MVDL800-5702-93-A, 800A liquid-cooled Delta power module
  • GE MVDL800-4702-93-A Delta power module
  • BACHMANN OT1200 Web Terminal Panel-PC Serie
  • BACHMANN OT1300 Operator Terminal Panel-PC Serie
  • BACHMANN PPC1200 ECO Panel-PC
  • BACHMANN PPC1200 Premium Panel-PC
  • BACHMANN GSP274 Netzerfassungs-, Synchronisations- und Schutzmodul
  • BACHMANN GMP232/x2 Netzmessungs- und Schutzmodul
  • BACHMANN GM260 Netzerfassungsmodul
  • BACHMANN PSI135 Energieversorgungsmodul Busschiene isoliert
  • BACHMANN BPC101 Leerplatzabdeckung
  • BACHMANN BPR1nn Busschienen für Tragschienenmontage
  • BACHMANN NPN102 Buskoppler PROFINET RT
  • BACHMANN NCN102/D Buskoppler CAN/CANopen
  • BACHMANN NCN102 Buskoppler CAN/CANopen
  • BACHMANN NEC102 Buskoppler EtherCAT
  • BACHMANN COM104 Serielles Schnittstellenmodul
  • BACHMANN COM102/D Serielles Schnittstellenmodul
  • BACHMANN COM102 Serielles Schnittstellenmodul
  • BACHMANN EAS102 Absolutwertgebermodul
  • BACHMANN EII102 Zähler- / Zeitmessungs- / Inkrementalgebermodul
  • BACHMANN AIM112 Analoges Eingangsmodul (Multi)
  • BACHMANN AIO116 Analoges Ein-/Ausgangsmodul
  • BACHMANN AIO112 Analoges Ein-/Ausgangsmodul
  • BACHMANN AIO104/I Analoges Ein-/Ausgangsmodul
  • BACHMANN UIO108 Universales Ein-/Ausgangsmodul
  • BACHMANN UIO106 Universales Ein-/Ausgangsmodul
  • BACHMANN DOH108 Digitales Ausgangsmodul (High Power)
  • BACHMANN DOS136 Digitales Ausgangsmodul
  • BACHMANN DOS124 Digitales Ausgangsmodul
  • BACHMANN DOS112 Digitales Ausgangsmodul
  • BACHMANN DOS108 Digitales Ausgangsmodul
  • BACHMANN DIS136 Digitales Eingangsmodul
  • BACHMANN DIS124 Digitales Eingangsmodul
  • BACHMANN DIS112 Digitales Eingangsmodul
  • BACHMANN DIS108 Digitales Eingangsmodul
  • BACHMANN CPS100 Prozessormodule CPS0212/E, CPS0212. CPS0415. CPS0419
  • BACHMANN CFA200 SLC CFast Memory Speicherkarte
  • BACHMANN CF200 UDMA Compact Flash Memory
  • BACHMANN PCC201 PC-Cards Speicherkarte
  • BACHMANN BS200/E Busschienen
  • BACHMANN BS200/S Busschienen
  • BACHMANN BS200 CC Busschienen
  • BACHMANN BS200 / S200 Busschienen
  • BACHMANN LM201 Leermodul
  • BACHMANN NT255 Netzteilmodul
  • BACHMANN BES212. BES212/N Buserweiterungsmodu
  • BACHMANN BEM211 Buserweiterungsmodul
  • BACHMANN DA3284-C CAN Slave Universal-Ein-/Ausgangsmodul
  • BACHMANN TCO216-C CAN Slave Temperatur-Ein-/Ausgangsmodul
  • BACHMANN TCO208-C CAN Slave Temperatur-Ein-/Ausgangsmodul
  • BACHMANN DIO264-C CAN Slave Digital-Ein-/Ausgangsmodul
  • BACHMANN DIO32-C CAN Slave Digital-Ein-/Ausgangsmodu
  • BACHMANN DIO16-C CAN Slave Digital-Ein-/Ausgangsmodul
  • BACHMANN MBUS201-Master Feldbusmodul - Adapter
  • BACHMANN SEM201 SERCOS Master Modul
  • BACHMANN DNM201 DeviceNet-Master
  • BACHMANN DPM200 PROFIBUS®-DP-Master-Modul
  • BACHMANN CM202 CAN-Interface-Modul
  • BACHMANN CS200/x Buskoppler für M200-Module
  • BACHMANN ERS202 Ethernet-Remote-Station
  • BACHMANN RS204 Schnittstellenmodul
  • BACHMANN EM213 Industrie-Ethernet-Master
  • BACHMANN PVA208 Proportionalventilverstärker
  • BACHMANN PVA204 Proportionalventilverstärker
  • BACHMANN ACR222/2 Schrittmotormodul
  • BACHMANN PWM202 Pulsweitenmodulationsmodul
  • BACHMANN ISI222/x Positioniermodul
  • BACHMANN CNT204/x Zählermodule
  • BACHMANN DMS202 Dehnmessstreifen-Eingangsmodul
  • BACHMANN TI214/x Temperaturerfassungsmodul
  • BACHMANN PTAI216 Temperaturerfassungsmodul
  • BACHMANN AO204/SI Analog-Ausgangsmodule
  • BACHMANN AO202/SI Analog-Ausgangsmodul
  • BACHMANN AO202 Analog-Ausgangsmodul
  • BACHMANN AI204/x Analog-Eingangsmodule
  • BACHMANN AI208/SI Analog-Eingangsmodul
  • BACHMANN AI204/SI Analog-Eingangsmodul
  • BACHMANN AI202/SI Analog-Eingangsmodul
  • BACHMANN AIO288/x Analog-Ein-/Ausgangsmodule
  • BACHMANN AIO208/SI Universal-Analog-Ein-/Ausgangsmodul
  • BACHMANN AIO204/SI Universal-Analog-Ein-/Ausgangsmodul
  • BACHMANN AIO202/SI Universal-Analog-Ein-/Ausgangsmodul
  • BACHMANN AIO216 Universal-Analog-Ein-/Ausgangsmodul
  • BACHMANN AIO208 Universal-Analog-Ein-/Ausgangsmodul
  • BACHMANN AIC214 Schwingungssensor-Eingangsmodul
  • BACHMANN AIC206 Schwingungssensor-Eingangsmodull
  • BACHMANN GIO212 Universal-Ein-/Ausgangsmodul
  • BACHMANN DOR206/230 Digital-Relais-Ausgangsmodul
  • BACHMANN DIO280 Digital-Ein-/Ausgangsmodul
  • BACHMANN DIO264 Digital-Ein-/Ausgangsmodul
  • BACHMANN DIO248 Digital-Ein-/Ausgangsmodul
  • BACHMANN DIO232 Digital-Ein-/Ausgangsmodul
  • BACHMANN DIO216/x Digital-Ein-/Ausgangsmodul
  • BACHMANN DO232 Digital-Ausgangsmodul
  • BACHMANN DO216 Digital-Ausgangsmodul
  • BACHMANN DI232/x Digital-Eingangsmodul
  • BACHMANN DI216 Digital-Eingangsmodul
  • BACHMANN MC200 Prozessormodule
  • BACHMANN MX200 Prozessormodule
  • Beckhoff FC9002 | Ethernet card, 2 channels, PCI
  • Beckhoff FC7502 | Sercos II master card, 2 channels, PCI™
  • Beckhoff FC7501 | Sercos II master card, 1 channel, PCI™
  • Beckhoff FC5322 | CAN FD card, 2 channels, PCIe® x1
  • Beckhoff FC5321 | CAN FD card, 1 channel, PCIe® x1
  • Beckhoff FC5202 | DeviceNet®, master/slave card, 2 channels, PCI™