KONG -Y
NameDescriptionContent
Location:

Woodward Product Change Notification 06912

From:Woodward | Author:kongjiang | Time :2026-01-20 | 757 Browse: | 🔊 Click to read aloud ❚❚ ▶ | Share:

Product Change Notification 06912

(Revision B, 6/2013)

Overview

Woodward is releasing new ProTech®-GII models on 17 May 2013. These new models include the same

basic functionality as current ProTech-GII models, and include the improvements listed below as well as

new capabilities.

In an effort to minimize the risk of future application issues, and since the new/improved models are direct

drop-in replacements for the existing models, Woodward plans to change all existing models to “non

preferred” on 15 July 2013. and all new models to “preferred”. Refer to Table 1 below for specific part

number information. Depending on the migration rate to the new ProTech-GII models, Woodward plans to

inactivate all old non-preferred models within the next 12 to 18 months. Please inform affected purchasing

teams and customers accordingly.

Product Change / Improvement

The below listed “preferred” models include the following changes, improvements, and additions:

1.

All module speed inputs are shared with all other modules (A, B, C).

All module trip and alarm latch output statuses are shared with all other modules (A, B, C).

All module “Start”, “Reset”, and “Speed Failed Override” commands are shared with all other modules

(A, B, C).

Added Speed Redundancy Manager Block:

With all input sensors/channels healthy, each module to be configured to select the desired

speed (median, HSS, or LSS) to use for its alarm and trip logic.

Upon one failed input sensor/channel, each module to be configured to select the desired speed

(HSS or LSS) to use for its alarm and trip logic.

Upon two failed input sensors/channels, each module to be configured to select the desired

action (issue a trip command or use healthy speed input sensor/channel for its alarm and trip

logic).

Allows users to configure the use of 3 or 2 or 1 speed input sensors/channels.

Includes “Speed Difference Detection” alarm function. Note that this feature can be easily used to

assist in detecting a failed active or passive speed sensor.

Note: New speed redundancy manager logic allows users to configure the voting logic to meet Shell’s

2-out-of-2 voting requirement when only two inputs are available/healthy.

Added Acceleration Redundancy Manager Block:

With all input sensors/channels healthy, each module to be configured to select the desired

acceleration rate (median, HSS, or LSS) to use for its alarm and trip logic.

Upon one failed input sensor/channel, each module to be configured to select the desired

acceleration rate (HSS or LSS) to use for its alarm and trip logic.

Allows users to configure the use of 3 or 2 or 1 speed input sensors/channels.

Added Boolean Input Manager Functions:

Each of the ProTech-GII’s contact/Boolean inputs (Start, Reset, and Speed Failed Override) can

be configured to use the respective contact/Boolean input command from any or all of the other

modules.

When configured, any or all of the configured discrete input commands are “ORed” together.

Example—If module A’s “Reset” function is configured to use module A’s and module B’s “Reset”

contact input commands, then a “Reset” command received from the A or B module will activate

module A’s Reset logic.

Boolean Input Manager functions can only be configured from the ProTech-GII’s PCT software

service tool.

The ORed Boolean Input Manager functions, if configured, only manage the action of a module’s

contact inputs commands. The Reset and Start keys on the module’s front panel function

independently of the Boolean Input Manager and only affect the respective module’s action.

Added configurable “Failed Power Supply #1” and “Failed Power Supply #2” Alarm Override functions.

Allows users to configure the module to accept only one power supply, thus removing a nuisance

Failed Power Supply Alarm indication.

Changed Speed Fail Alarm function to be overridden during the turbine start state/mode.

This removes a nuisance alarm during a turbine start-up.

Changed Speed Lost Alarm/Trip threshold level from 100 Hz to 200 Hz to reduce/remove nuisance

alarms/trips when applied with speed gears that have less than 60 teeth and turbines that can slow roll

at low speeds.

10. Changed the name of “Periodic Overspeed Test” to “Auto Sequence Test”.

11. Added an option to start the Auto Sequence Test Routine from the Auto Sequence Test screen. This

allows a user to instantly start the Auto Sequence Test function when desired.

12. Added an option to disable Auto Sequence Test routine from the Auto Sequence Test screen. This

allows a user to disable the Auto Sequence Test function from being performed. Since the Auto

Sequence Test routine can be configured to be performed on a periodic basis, the “Disable” function

allows users to temporarily disable the periodic test routine from being performed when desired.

13. Added an Auto Simulated Speed Test Failed Alarm to indicate the failure of the Auto Simulated Test

routine.

14. Added a configurable permissive for any Test routine, which will not allow the Test function to be

started if any other module has an “Alarm” condition active. Users now have the following configurable

Test “permissive” options: None, Module Not Tripped, or Module Not In Alarm. If configured, the test

  • Eaton SPN6084LEAXX2F Power Defense SB
  • Eaton MPNC4N3LEAXXSW Magnum low voltage power circuit breaker
  • EatonSP N8403YEAXX2H Power Defense SB
  • Eaton MPS8604WEAXX2C Magnum low voltage power circuit breaker
  • Eaton MPS8404WEAXXSW Magnum low voltage power circuit breaker
  • Eaton MPN6504LEAXX3A
  • Eaton MPSC323VEAXX2A Magnum low voltage power circuit breaker
  • Eaton SPS6304WEAXX2F Power Defense SB
  • Eaton MPN6504LEAXX2H Magnum low voltage power circuit breaker
  • Eaton MPSC504HEAXX2H Magnum low voltage power circuit breake
  • Eaton SPN85N3LEAXX2F Power Defense SB
  • Eaton SPN6403CEAXX2F Power Defense SB
  • Eaton MPSC5N4MEAXX3A Power Defense SB
  • Eaton SPSC124WEAXX2A Power Defense SB
  • Eaton SPS85A4WEAXX2H Power Defense SB
  • Eaton SPSC5N4MEAXX2A Power Defense SB
  • Eaton MPN8403VEAXX2H Magnum low voltage power circuit breaker
  • NZMB2-4-A200 MCCB NZM, NZM2 TM and Elec
  • Eaton NZMN1-A63 Series NZM complete molded case circuit breaker
  • Eaton NZMB1-S26-CNA Series NZM complete molded case circuit breaker
  • Eaton NZMH2-A25-NA Series NZM complete molded case circuit breaker
  • NZMH2-A200-BT-NA Eaton Series NZM complete molded case circuit breaker
  • NZMN4-VEF1200-NA Eaton Series NZM complete molded case circuit breaker
  • NZMH2-AF250-NA MCCB NZM, NZM2 TM and Elec
  • NZMB1-AF60-NA Eaton Series NZM complete molded case circuit breaker
  • NZMN1-A50 Eaton Series NZM complete molded case circuit breaker
  • NZMH2-A80-NA Eaton Series NZM complete molded case circuit breaker
  • Eaton Cutler-Hammer HFD3030 6639C86G87 3 Pole 30A 600V Circuit Breaker
  • Moeller XV-230-57CNN-1-13-1 HMI PLC Panel Touchscreen 5.7"
  • EATON CEAG CU CG-S , 40071360300 Control Unit
  • EATON SDN90186 MOTOR CONTROL CENTER
  • EATON HMCP150U4 CIRCUIT BREAKER
  • Eaton 7801C57 Digitrip Optimizer Hand Held Programmer
  • Eaton HMCP400R5 Circuit Breaker
  • EATON MP-3000 SAFETY RELAY 66D2032GX1
  • EATON PGGLOBL1701DPRO 1785T Touch Panel
  • Eaton, Moeller, Easy MFD-CP8-NT
  • Eaton WL-35717F Vacuum Interrupter
  • EATON VICKERS EEA-PAM-535-A-32 AMPLIFIER CARD
  • EATON FP5000-00 / FP5200-00 66D2041G11 FEEDER PROTECTION RELAY
  • Eaton IQ-504 120VAC Modular Overload Relay
  • Beckhoff CX5620-0225    CPU module
  • Beckhoff CX5620-0220    CPU module
  • Beckhoff CX5620-0215    CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0210 CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0195    CPU module
  • Beckhoff CX5620-0190    CPU module
  • Beckhoff CX5620-0185    CPU module
  • Beckhoff CX5620-0175    CPU module
  • Beckhoff CX5620-0170  CPU module
  • Beckhoff CX5620-0163    CPU module
  • Beckhoff CX5620-0162 CPU module
  • Beckhoff CX5620-0161 CPU module
  • Beckhoff CX5620-0160 CPU module
  • Beckhoff CX5620-0100 CPU module
  • Beckhoff CX5120-0195    CPU module
  • Beckhoff CX5120-0190 CPU module
  • Beckhoff CX5120-0185 CPU module
  • Beckhoff CX5120-0175 CPU module
  • Beckhoff CX5120-0170    CPU module
  • Beckhoff CX5120-0163    CPU module
  • Beckhoff CX5120-0162    CPU module,
  • Beckhoff CX5120-0161    CPU module
  • Beckhoff CX5120-0160 CPU module,
  • Beckhoff CX5120-0150 CPU module
  • Beckhoff CX5120-0143 CPU module
  • Beckhoff CX5120-0142 CPU module
  • Beckhoff CX5120-0141 CPU module, Microsoft Windows 10 IoT Enterprise 2016 LTSB
  • Beckhoff CX5120-0140 CPU module
  • Beckhoff CX5120-0130 CPU module
  • Beckhoff CX5120-0123 CPU module
  • Beckhoff CX5120-0122 CPU module
  • Beckhoff CX5120-0120 CPU module
  • Beckhoff CX5120-0113 CPU module
  • Beckhoff CX5120-0112 CPU module
  • Beckhoff CX5120-0111 CPU module
  • Beckhoff CX5120-0110 CPU module
  • Beckhoff CX5120-0100 CPU module, no operating system
  • Beckhoff C6017-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6017 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0030  | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015 | Fanless ultra-compact Industrial PC
  • Beckhoff CX2500-M510 | Fieldbus master module
  • Beckhoff CX2500-M310 | Fieldbus master module
  • Beckhoff CX2500-B510 | Fieldbus slave module
  • Beckhoff CX2500-B310 | Fieldbus slave module PROFIBUS for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0070 | USB 3.0 module for CX20xx, CX52xx, CX53x0. CX56x0
  • Beckhoff CX2500-0062 | 2.5 Gbit Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1061 | Power over Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1060 | Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0031 | Serial Interface RS485/RS422
  • Beckhoff CX2500-0030 | Serial Interface RS232 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX5230-0195 CPU module
  • Beckhoff CX5230-0190    CPU module
  • Beckhoff CX5230-0175    CPU module,
  • Beckhoff CX5230-0170  CPU module
  • Beckhoff CX5230-0100    CPU module, no operating system, no TwinCAT
  • Beckhoff CU8130-0240 | UPS modul, battery-backed
  • Beckhoff CU8130-0120 | UPS module, battery-backed
  • Beckhoff CU8110-0120 | UPS module, capacitive
  • Beckhoff CU8110-0060 | UPS module, capacitive
  • Beckhoff CX5130-0195    CPU module
  • Beckhoff CX5130-0190    CPU module
  • Beckhoff CX5130-0185 CPU module
  • Beckhoff CX5130-0170    CPU module
  • Beckhoff  CX5130-0163 CPU module, Microsoft Windows 10 IoT Enterprise 2019 LTSC, 32 bit
  • Beckhoff  CX5130-0162    CPU module
  • Beckhoff CX5130-0161  CPU module
  • Beckhoff CX5130-0160    CPU module
  • Beckhoff CX5130-0155  CPU module
  • Beckhoff CX5130-0150    CPU module
  • Beckhoff CX5130-0143 CPU module
  • Beckhoff CX5130-0142 CPU module
  • Beckhoff CX5130-0140    CPU module
  • Beckhoff CX5130-0135 CPU module
  • Beckhoff CX5130-0130 CPU module
  • Beckhoff CX5130-0125    CPU module
  • Beckhoff CX5130-0123    CPU module
  • Beckhoff CX5130-0122    CPU module
  • Beckhoff CX5130-0121 CPU module
  • Beckhoff CX5130-0115    CPU module,
  • Beckhoff CX5130-0113    CPU module
  • Beckhoff CX5130-0112   CPU module
  • Beckhoff CX5130-0111   CPU module
  • Beckhoff CX5130-0110 CPU module, Microsoft Windows Embedded Compact 7. no TwinCAT
  • Beckhoff CX5130-0100  CPU module, no operating system, no TwinCAT
  • DEIF FAS-113DG Synchronisation & circuit breaker closing