Woodward MFR 300 Multifunction Relay / Measuring

From:Woodward | Author:kongjiang | Time :2026-03-13 | 21 Browse: | Share:

MFR 300

Multifunction Relay / Measuring

Transducer with CANopen /

Modbus Communication

APPLICATIONS

The MFR 300 is a measuring transducer for

monitoring single- and three-phase power

systems. The MFR 300 has both voltage and

current inputs for measuring an electrical power

source. A digital processor makes it possible to

accurately to measure true RMS values,

regardless of harmonics, transients or

disturbing pulses. The primary measured and

calculated values are transmitted via CANopen

/ Modbus protocol to a supervisory control

system.

The MFR 300 performs monitoring functions for

mains decoupling, including four freely

configurable time-dependent undervoltage

monitoring functions for FRT (fault ride

through).

The primary measured values of voltage and

current are used to calculate the real, reactive,

and apparent power and the power factor

(cosphi) values.

The list of measured values includes

• Measured

o Voltage

 Wye: VL1N / VL2N / VL3N

 Delta: VL12 / VL23 / VL31

o Frequency fL123

o Current IL1/IL2/IL3

• Calculated

o Average voltage VØL123 / Vmin / Vmax

o Average current IØL123 / Imin / Imax

o Real power Ptotal / PL1 / PL2 / PL3

o Reactive power Qtotal

o Apparent power Stotal

o Power factor (cosφL1)

o Active energy kWhpositive/negative

o Reactive energy kvarhleading/lagging

DESCRIPTION

Features

• 3 true RMS voltage inputs

• 3 true RMS current inputs

• Class 0.5 accuracy for voltage,

frequency and current

• Class 1 accuracy for real and

reactive power or energy

• Configurable trip/control setpoints

• Configurable delay timers for

individual alarms (0.02 to 300.00 s)

• 4 configurable relays (change-over)

• 1 “Ready for operation” relay

• Switchable relay logic

• 2 kWh counters (max. 1012 kWh)

• 2 kvarh counters (max. 1012 kvarh)

• CANopen / Modbus communication

• Configurable via CAN bus / RS-485

/ Service Port (USB/RS-232)

• 24 Vdc power supply

Protection (all) ANSI #

• Over-/undervoltage (59/27)

• Over-/underfrequency (81O/U)

• Voltage asymmetry (47)

• Overload  (32)

• Positive/negative load (32R/F)

• Unbalanced load (46)

• Phase shift  (78)

• Overcurrent   (50/51)

• df/dt (ROCOF)

• Ground fault

• QV monitoring

• Voltage increase

• Freely configurable time-dependent

undervoltage monitoring for:

o FRT (fault ride-through)

Accuracy ....................................................................................... Class 0.5

Power supply .......................................................... 12/24 Vdc (8 to 32 Vdc)

Intrinsic consumption .................................................................... max. 5 W

Ambient temperature (operation) ................ -20 °C (-4 °F) / 70 °C (158 °F)

Ambient temperature (storage) ................. -40 °C (-40 °F) / 85 °C (185 °F)

Ambient humidity ...................................................... 95 %, non-condensing

Voltage ........... Rated value /∆: [1] 69/120 Vac or [7] 400/690 Vac

Rated voltage Vph-ground: [1] 150 Vac or [7] 600 Vac

Max. cont. voltage Vph-ph: [1] 150 Vac or [7] 862 Vac

Rated surge voltage: [1] 2.5 kV or [7] 6.0 kV

Measuring frequency ................................................................. 45 to 65 Hz

Linear measuring range ............................................................ 1.25 × Vrated

Input resistance ........................................................................ [1] >0.5 MΩ

[7] >2.0 MΩ

Max. power consumption per path ................................................... 0.15 W

Current (Irated) ................................................................. [1] ../1 A, [5] ../5 A

Linear measuring range .................................................................. 3 × Irated

Max. power consumption per path ............................................... < 0.15 VA

Rated short-time current (1 s) ................................... [1] 10 Aac, [5] 50 Aac

Relay outputs ................................................................................ isolated

Contact type ..............................................................Form C (change-over)

Contact material ............................................................................... AgCdO

Load (GP) ...................................................................... 2.00 Aac@250 Vac

....................2.00 Adc@24 Vdc / 0.36 Adc@125 Vdc / 0.18 Adc@250 Vdc

Pilot duty (PD) ..............................................................................................

....................1.00 Adc@24 Vdc / 0.22 Adc@125 Vdc / 0.10 Adc@250 Vdc

Housing ....................................................... Type Extrusion profile UM122

for DIN rail mounting

Dimensions ................................................................... 146 × 128 × 50 mm

Connection ................................................ screw/plug terminals depending

on connector 2.5 mm² (14 AWG)

Protection system ................................................................................. IP20

Weight .................................................................................... approx. 300 g

Disturbance test (CE) .......... tested according to applicable EN guidelines

Listings ................................. UL/cUL listed (File No.: E231544), GOST-R



  • Woodward easYgen-3200-1/P1 8440-2049
  • Woodward easYPROTEC-1410-7 8441-1161 8441-1160
  • Woodward MFR300-71M/K45 8444-1111 8444-1112
  • Woodward MFR300-75M 8444-1107 8444-1108 8444-1109
  • Woodward MFR300-71M/K42 8444-1104
  • Woodward MFR300 75M/SU03, Transducer 8444-1093 8444-1094 8444-1095
  • Woodward MFR300-71M 8444-1091 8444-1092
  • Woodward MFR300-15M 8444-1090 8444-1089
  • Woodward MFR300-11M 8444-1071 8440-1089
  • Woodward MFR500-6M/WK0400 + DPC USB 8444-1070
  • Woodward MFR300-15M 8444-1064
  • Woodward SPM-D2-1040B/NYB 8440-2189
  • Woodward SPM-D2-1010B/NYB 8440-2177
  • Woodward SPM-D2-10B/PSY5-FU-D 8440-2170
  • Woodward SPM-D2-1040B/XN analog speed/voltage bias 8440-2190
  • Woodward MFR300-71M 8444-1063
  • SPM-D2-1010B/X analog speed/voltage bias 8440-2168
  • Woodward SPM-D2-1040B/X analog speed/voltage bias 8440-2171
  • Woodward SPM-D2-1010B/N wide range power supply 8440-2174
  • Woodward SPM-D2-1040B/N wide range power supply 8440-2175
  • Woodward SPM-D2-1010B /110VAC sensing 8440-2166
  • Woodward SPM-D2-1040B /400VAC sensing 8440-2164
  • Woodward DTSC-200A 8440-2297
  • Woodward DTSC-200-55B/K38 8440-2155
  • Woodward DTSC-200-51B 8440-1867 8440-1868
  • Woodward 8445-1049 8445-1048 Converter, 1x FO to CAN
  • Woodward easYlite-200 8446-1007 LED Lamp Expansion Module
  • Woodward IKD-OUT-16 16 DO Expansion Card 8440-2306
  • Woodward IKD-IN-16 16 DI Expansion Card 8440-2307
  • Woodward IKD1M 8 DI/8 DO Expansion Card 8440-2116
  • Woodward easYview-07-30 8446-1071
  • Woodward easYFLEX-3400XT-P2 (GAP) 8440-2217
  • Woodward easYFLEX-3400XT-P2 (GAP) 8440-2217
  • Woodward easY-I-3400XT-P1 8440-2293
  • Woodward easY-I-3500XT-P1 8440-2292
  • Woodward MSLC-2XT 8440-2298 Master Synchronizer and Load Control
  • Woodward DSLC-2XT 8440-2299 Digital Synchronizer and Load Control
  • Woodward: GC-3400XT-P1 8440-2267 Group Controller
  • Woodward: LS-612XT-P2 8440-2317
  • Woodward: CONTROL-LS-612XT-P1,8440-2222 Cabinet back mounting
  • Woodward: LS-522-1/P1 8440-2179
  • Woodward: LS-522-5/P1 8440-2151
  • Woodward: LS-512-1/P1 8440-2181
  • Woodward: LS-512-5/P1 8440-2153
  • Woodward: LS-521-1/P1 8440-2178
  • Woodward: CONTROL-LS-521-5/P1 8440-2150
  • Woodward: LS-511-1/P1 8440-2180 Circuit Breaker Control & Protection
  • Woodward: CONTROL-LS-511-5/P1 8440-2152 Circuit Breaker Control & Protection
  • Woodward easYgen-3500XT-P2-LT-RENTAL 8440-2291 Genset Control for
  • Woodward eeasYgen-3500XT-P2-RENTAL 8440-2290
  • Woodward easYgen-3200XT-RENTAL 8440-2285
  • easYgen-3500XT-P2-K58 8440-2318
  • easYgen-3500XT-P2-LT 8440-2089
  • Woodward easYgen-3500XT-P2 8440-2088 Genset Controller
  • Woodward: easYgen-3500XT-P1-LT 8440-2086
  • Woodward: easYgen-3500XT (P1) 8440-2085
  • Woodward: easYgen-3400XT (P2), Genset Controller 1A/5A 8440-2087
  • Woodward: easYgen-3400XT (P1) 8440-2084
  • Woodward 8440-2082 EasyGen 3200XT Genset Controller
  • Woodward: easYgen-3200XT (P1/LT) 8440-2083
  • Woodward: easYgen-3100XT 8440-2081
  • Woodward: easYgen-2500 (1A/P1) K33 8440-2096
  • Woodward easYgen-2500-5/P1-K33 Rental Version 8440-2029
  • Woodward easYgen-2500-1/P1 8440-1860
  • Woodward easYgen-2500-5/P1 8440-1884
  • Woodward easYgen-2300-1/P2 8440-2123 Controller
  • Woodward easYgen-2300-5/P2 8440-2058
  • Woodward 2300E – Ordinary Locations 8273-1017
  • Woodward Vertex Compressor Control 8200-1370
  • MicroNet Safety Module - Bulkhead Mount 8237-2492 Woodward
  • ProTech TPS - Bulkhead Mount Independent Relays 8237-2602
  • Woodward ProTech-GII - Bulkhead Mount Independent Relays 8237-2594
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX411/511010/STD Single and dual input analyzers
  • Woodward ProTech-SX - Panel Mount, HV/LV 8237-1242 8237-1243
  • Woodward SPC Servo Position Controller 8200-226 8200-227
  • Woodward Peak200 – Bulkhead Mount, LV 8200-1500
  • Woodward 505HT for Pelton Turbines 8200-1400, 8200-1401
  • Woodward 2301E-HT Hydro (Francis Turbines) P/N 8237-2046
  • Woodward 8273-1013 8273-1014 Digital Electronic Load Sharing
  • Control Panel 9907-2024 Woodward
  • ABB REF630 UBFNAAABBBAZANBBXB Feeder Protection and Device
  • ABB PPD513 A2A-11165 High-performance controller
  • UniOP CP10G-04 CP10G-04-0045 Interface Module
  • UNIOP MKDR-04-0021 Monochrome LCD (with Contrast Control)
  • UNIOP eTOP03-0046 Monochrome LCD (STN)
  • UNIOP MKDR-16-TA-0045 HMI TOUCH SCREEN
  • UNIOP Operator Interface Display MD02R-04-0042
  • UniOP Display Screen eTOP20C-0050 eTOP20C
  • UniOp eTOP05-0045 eTOP05. eTOP05P Operator Interface Touch Panel
  • UNIOP ETOP11-0050 HMI 5.6Color Operator Interface Touch Panel
  • UniOp eTOP306 Panel
  • UniOP eTOP308 ETOP308U301 HMI Panel
  • UniOP ePALM10-0061 Handheld Robot Trainer
  • UniOP CP01R-04 CP05R-04 and CP01F-02
  • Uniop MD02R-04 - MD02R-04-0045 Industrial PLC Workstation
  • Uniop Cp02r-04-0021 Operating Interface
  • UniOP ECT-16-0045 High-Performance Color Touchscreen HMI
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD04-0046 Compact Industrial Interface
  • UniOP BKDR-16 High-Reliability Monochrome Operator Interface
  • UniOP MKDR-04-004 Control Unit Panel
  • UniOP eTOP515 Series 500 HMI
  • Woodward 9907-1199 Advanced CPC-II Current-to-Pressure Converter
  • Woodward 8200-1300 High-Precision 505D Steam Turbine Controller
  • ABB PFSK130 3BSE002616R1 Core Signal Conditioning Unit
  • ABB PFSK165 3BSE027778R1 VP74201-933CW07 Signal Processing and Communication Unit
  • ABB PFSK164 3BSE021180R1 Tension sensor module and processing board
  • ABB 3BSE006505R1 PFSK142 Control board
  • ABB PFSK160A 3BSE009514R1 Regulated High-Capacity 24V DC
  • ABB PFSK162 3BSE015088R1 Signal Conditioning and Processing Board
  • ABB PFSK152 3BSE018877R1 Signal concentrator board
  • ABB PFSK151 3BSE018876R1 High-performance signal processing unit
  • ALSTOM PIB1201A 3BEC0067 Power Interface Board (PIB)
  • ALSTOM PIB310 3BHB0190 Adapter Module / Printed Circuit Board (PCB)
  • ALSTOM PIB102A 3BEB0180 Communication Card / PCB Module
  • ALSTOM BGTR8HE 24491276A1004 High-Frequency Power Controller / Rack Module
  • ALSTOM LC105A-1 Digital Discrete Output (Relay)
  • ALSTOM IR139-1 High-Efficiency Inverter / Control Board
  • ALSTOM AM164 Analog Output / Remote I/O
  • ALSTOM LE109A-1 Power System Control and Monitoring Module
  • ALSTOM UT150-1 PID temperature controller / process control board
  • ALSTOM AL132 AL132A STO0982E01 Control Motherboard / CPU Card
  • ALSTOM AS111-1 Analog Output (AO) Module
  • WATLOW AH116-2 Servo Drive / Control Module
  • WATLOW V4555724-0100 Electromechanical Contactor /Power Switch
  • Alstom KCEU142 Digital Protection Relay
  • ALSTOM MMLG01 Test block