KONG -Y
NameDescriptionContent
Location:

Woodward MicroNet Safety Module (MSM)

From:Woodward | Author:kongjiang | Time :2026-03-04 | 766 Browse: | 🔊 Click to read aloud ❚❚ | Share:

A configurable low-pass filter was added to the acceleration signal.

Front Panel Display changes:

Speed display: The precision of the speed value on the front panel provides one decimal

precision when below 100 rpm. Configurable filtering added to the displayed speed value.

Improved front panel performance, providing faster response to a key press.

Analog Input display: Expanded the front panel display of the analog input to show the level

setpoints (e.g. Hi, Lo) as well as all the level status indications.

Trip button (front panel): Toggles display between the Trip Log and the Trip Latch.

Alarm button (front panel): Toggles display between the Alarm Log and the Alarm Latch.

Added Shared Reset, Shared Start, and Shared Speed Fail Override display screens.

Trip Latch inputs were rearranged to display more practical faults first (e.g. overspeed).

Modbus: A) Included the outputs of all analog logic blocks as Modbus analog/register reads.

B) The address numbering (Boolean and register) changed to be consecutive, removing

huge gaps in numbering. C) Added Spare Boolean read registers to prevent errors

experienced by devices that queried in increments of 16. D) Added 20 scalable analog reads,

allowing the user to select the source and set the signal scaling (for very large or very small

analog signals).

Expanded the configurable logic Boolean connections to include both the local and shared

signals for start, reset, and speed fail override.

New logic connections added:

Local and Shared Start

Local and Shared ResetLocal and Shared Speed Fail Override

ARM block Difference Detected

Outputs from the new analog blocks

Configuration Checking enhancements implemented:

Power-up trip (trip relay must be set for de-energize for trip)

configuration mismatch (function must be enabled)

Speed fail alarm (function must be enabled and local speed must enabled)

Speed Fail Trip and Speed Fail Timer (function must be enabled and speed must be

enabled)

GAP Programming Environment Updated

Updated the MSM GAP/simulation tool to include the firmware updates in this release. This tool

allows users to program the MSM using graphical function block code. 9927-2151 Revision B or

newer is required. Refer to manual 26712 for details on this tool.

This tool provides the following:

Graphical view of entire application

Completeness check to ensure the program will be accepted by the device

Documented feedback of the ProTech CRC codes to ensure program ‘fingerprint’ verifying laptop

GAP program & installed ProTech settings

GAP Block help clarifying the function and input/output fields of each block

Built-in simulation on the user PC to allow testing/debugging of logic

Simulation that allows manual entry (control) of Input signals

Compatibility Notes and Table

Field Software Conversion kit 8929-038 is compatible with and can be used to convert most older

MSM models to the newer models listed below. See table below for compatibility information.

Description

Part Numbers that Can Be Converted

MSM – Bulkhead Mount, HV/LV, Ind. Relays

8237‐1252 Rev D or Newer or 8237-1492

MSM – Bulkhead Mount, HV/HV, Ind. Relays

8237‐1253 Rev D or Newer or 8237-1493

MSM – Bulkhead Mount, HV/LV, Voted Relays

8237‐1254 Rev D or Newer or 8237-1494

MSM – Bulkhead Mount, HV/HV, Voted Relays

8237‐1255 Rev D or Newer or 8237-1495

MSM – Panel Mount, HV/LV, Ind. Relays

8237‐1375 Rev D or Newer or 8237-1496

MSM – Panel Mount, HV/HV, Ind. Relays

8237‐1376 Rev D or Newer or 8237-1497

MSM – Panel Mount, HV/LV, Voted Relays

8237‐1377 Rev D or Newer or 8237-1498

MSM – Panel Mount, HV/HV, Voted Relays

8237‐1378 Rev D or Newer or 8237-1499

MSM – Field Software Conversion Kit

8929-038

Only MSM Service Tool (9927-1684 Rev. F or newer) is compatible with both new and old MSM

models. Note that the latest revision of this service tool can be obtained/ downloaded from

Woodward’s website

Configuration files from older MSM models can be loaded into new MSM models using the MSM

service tool. However, configuration files from new MSM models cannot be loaded into older MSM

models.

Preferred Model Numbers

The following table shows the new/improved “preferred” MSM part numbers:

Description

Non-Preferred

Part Number

Preferred Part

Number

MSM – Bulkhead Mount, HV/LV, Ind. Relays

8237-1492

8237-2492

MSM – Bulkhead Mount, HV/HV, Ind. Relays

8237-1493

8237-2493

MSM – Bulkhead Mount, HV/LV, Voted Relays

8237-1494

8237-2494

MSM – Bulkhead Mount, HV/HV, Voted Relays

8237-1495

8237-2495

MSM – Panel Mount, HV/LV, Ind. Relays

8237-1496

8237-2496

MSM – Panel Mount, HV/HV, Ind. Relays

8237-1497

8237-2497

MSM – Panel Mount, HV/LV, Voted Relays

8237-1498

8237-2498

MSM – Panel Mount, HV/HV, Voted Relays

Customer Action

8237-1499

8237-2499

Customers who are currently using any MSM model and do not require any of the above listed

changes/improvements should take no action. Woodward is committed to supporting the listed “non

preferred” models for a period of 20 years after inactivation. Refer to the related product support plan

for these models.

After January 30. 2018. Woodward recommends that customers who are purchasing MSM units for use

in new applications order part numbers from the “preferred” part number list only.

After January 30. 2018. customers who currently own an older MSM model and wish to have/utilize one

  • SHINKAWA MODEL VM-5Z5,6,7  POWER SUPPLY UNIT
  • SHINKAWA MODEL VM-5Y1,2,3 RELAY MODULE UNIT
  • SHINKAWA MODEL VM-5P3 PHASE MARKER UNIT
  • SHINKAWA MODEL VM-53 DUAL COMMUNICATION UNIT
  • SHINKAWA MODEL VM-52 BOTTOM HOLD MONITOR
  • SHINKAWA MODEL VM-51 ROD DROP MONITOR
  • SHINKAWA MODEL VM-5R TACHOMETER
  • SHINKAWA MODEL VM-5S DUAL TACHOMETER
  • SHINKAWA MODEL VM-5A DUAL VALVE
  • SHINKAWA MODEL VM-5E DUAL CASE
  • SHINKAWA MODEL VM-5L COMPLEMENTARY INPUT
  • SHINKAWA MODEL VM-5N RAMP DIFFERENTIAL
  • SHINKAWA MODEL VM-5D DUAL DIFFERENTIAL
  • SHINKAWA MODEL VM-5T DUAL THRUST MONITOR
  • SHINKAWA MODEL VM-5C ECCENTRICITY MONITOR
  • SHINKAWA MODEL VM-5C ECCENTRICITY MONITOR
  • SHINKAWA MODEL VM-5M DUAL PATH MONITOR
  • SHINKAWA MODEL VM-5B DUAL ACCELERATION MONITOR
  • SHINKAWA MODEL VM-5B DUAL ACCELERATION MONITOR
  • SHINKAWA MODEL VM-5U DUAL SEISMIC MONITOR
  • SHINKAWA MODEL VM-55 VIBRATION MONITOR
  • SHINKAWA VM-742B1-5 VIBRATION MONITORING SYSTEM CARD
  • Shinkawa PSP-17B P-24-64A P-24-64B Circuit Board Module
  • SHINKAWA MGP-67 PCB
  • Shinkawa JBP-278 P-22-48A-1 P-22-48B-1 Circuit Board Module
  • Shinkawa VM-721B 18-CHANNEL RELAY MODULE
  • Shinkawa FRP-337 P-26-54A P-26-54B Circuit Board Module
  • Shinkawa WKN-142K2-2 Vibration Transmitter
  • SHINKAWA VL-202A08L-1012 Rotor Position Monitor Probe Sensor
  • Shinkawa CPP-128 P-26-74A P-26-74B Circuit Board Module
  • Honeywell 51402755-100 PROCESSOR CARD
  • Honeywell 51107595-100 Power
  • HONEYWELL 51304544-100 Control Board
  • HONEYWELL 51109919-100 BOARD
  • HHoneywell 51204160-175 Digital Input Module
  • Honeywell 51304754-150 High Level Analog Input Module
  • HONEYWELL 51304690-100 DIGITAL INPUT CARD
  • Honeywell 51401635-150  COMM CONTROL
  • HONEYWELL 51204174-175 MC-TAOY 52 ANALOG OUTPUT BOARD
  • HONEYWELL  51400596-100
  • HONEYWELL 51401291-100 board card
  • HONEYWELL 51401642-150 I/O LINK MODULE
  • Honeywell LCN‑E Hub Power Supply 38500148‑300
  • Honeywell LCN‑E Hub redundant 38500143‑202 Twisted‑pair LCN
  • Honeywell LCN‑E Hub non‑redundant,38500143‑102
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MX‑DTAC01K2
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MX‑DTAB01K2
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MT11‑520
  • Honeywell STI‑CE Smart Transmitter Interface 51304516‑150
  • Honeywell STI Smart Transmitter Interface 51304516‑100 MC‑PSTX02
  • Honeywell ulse Counter IOP 51304386‑100 MU‑PPIX02
  • Honeywell DO Digital Output IOP‑CE 51304487‑150 CE  version
  • Honeywell DO Digital Output IOP  51304487‑100 MC‑PDOX02
  • Honeywell TDC‑3000 SOE DI IOP,51402625-175 MC‑PDIS12
  • Honeywell TDC‑3000  DI Digital Input IOP‑CE 51304485‑150
  • Honeywell TDC‑3000 DI Digital Input IOP 51304485‑100 MC‑PDIX02
  • Honeywell TDC‑3000 AO Analog Output IOP 51304757‑100 MU‑PAOX02
  • Honeywell TDC‑3000  TC Thermocouple IOP 51304756‑100 MU‑TAMT03
  • Honeywell TDC‑3000   51304755‑100 MU‑TAMR03
  • Honeywell TDC‑3000 LLAI Multiplex AI IOP,51304362‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP‑CE, 51304363‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP,51304363‑100.4‑20mA
  • Honeywell TDC‑3000  HPM Power Supply,51401731‑100
  • Honeywell TDC‑3000 Standard 1986.HPM High‑Performance PM CPU,51402362‑100
  • Honeywell TDC‑3000 APM Advanced Process Manager CPU,51304459‑100
  • Honeywell TDC‑3000 Standard 1986.PM Process Manager CPU,51304362‑100
  • Honeywell TDC‑3000 NIM Network Interface Module,51304481‑200
  • Honeywell TDC‑3000 NIM Network Interface Module 51304481‑100
  • Honeywell TDC‑3000 BASIC,LCN Terminator Resistor,30732052‑001.Coaxial
  • Honeywell TDC‑3000 BASIC,Hiway Coupler,30753732‑001
  • Honeywell TDC‑3000 BASIC,LEPIU Low‑Energy PIU,4DP7APCFA309
  • Honeywell TDC‑3000 BASIC,HLPIU High‑Level PIU,4DP7APCFA106
  • Honeywell TDC‑3000 BASIC,Multifunction Controller(TDC‑2000 DHW),4DP7MFA103
  • Honeywell TDC‑3000 BASIC,Extended Controller(TDC‑2000 DHW),4DP7AXA102
  • Honeywell TDC‑3000 BASIC,Basic Controller(TDC‑2000 DHW),4DP7BBA101
  • Honeywell 51305508‑100 TDC‑3000 BASIC,XLCNE2 LCN Extender
  • Honeywell TDC‑3000 BASIC,E‑PLCG PLC Gateway,51400997‑200
  • Honeywell TDC‑3000 BASIC,PLNM Plant Network Module,51401163‑100
  • Honeywell TDC‑3000 BASIC,CG Computer Gateway,80360206‑001
  • Honeywell TDC‑3000 BASIC,HG High‑Speed Gateway,51304526‑100
  • Honeywell TDC‑3000 BASIC,HM History Module,51191596‑200
  • Honeywell TDC‑3000 BASIC,HM History Module,51191596‑100
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑800.K2LCN‑8
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑600.K2LCN‑6
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑400,K2LCN‑4
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑300.K2LCN‑3
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑200,K2LCN‑2
  • Honeywell TDC‑3000 BASIC,US Universal Station CPU,51401288‑200
  • Honeywell TDC‑3000 BASIC,US Universal Station CPU,51401288‑100
  • SHINKAWA VM-21P1 Signal Conditioner 0-50MM 24VDC
  • Shinkawa RiverNew Vibration Transducer VK202 Series
  • Shinkawa Electric VM-3E2 Vibration Monitor Module
  • Shinkawa JBP-47 P-22-48A-1 / P-22-48B-1 Circuit Board Module
  • Shinkawa MODEL VM-5K DUAL VIBRATION MONITOR
  • Shinkawa CMU-15A (CMU15A) Industrial Camera Controller
  • Shinkawa CMU-13A CMU13A Industrial Camera Controller
  • Shinkawa EFU-10 (EFU10) Spark Generator Unit
  • Shinkawa UTC-1000 ZUP-02C Board
  • Shinkawa MDP-89 MDP89 P-24-674A P-24-674B Circuit Board Module
  • Shinkawa CB-1011005001 Signal Cable Assembly
  • SHINKAWA VL-202A08L-1002 Sensor VL-08020L01 Probe Cable F84N1695
  • Shinkawa VK-202A2 Driver & VL-202A08L-1A72 Proximity Sensor Probe
  • SHINKAWA VM-703B VIBRATION MONITORING SYSTEM CARD 2R05-002-P001C
  • Shinkawa BH-150-03 Signal Conditioner / Preamplifier Unit
  • Shinkawa BH-150 Signal Conditioner / Preamplifier Unit
  • Shinkawa Electric VM-3D2 Thrust Monitor Module
  • Shinkawa LCU-37 Monitoring module
  • Shinkawa LCU-44B-06 Local Control Unit Module
  • ABB 3BHE039724R2643 PPD513 high-performance programmable controller module
  • Samsung SSAS21-RTD Resistance Temperature Detector Input Module
  • Samsung SSAS21-AI Analog Input Module
  • Samsung SSAS21-DO Digital Output Module
  • Samsung SSAS21-DI Digital Input Module
  • Samsung SSAS21-CPU Central Processing Unit Module
  • Samsung SMTB-RTD RTD/TC Terminal Board
  • Samsung SMTB-AI Analog Input/Output Terminal Board
  • Samsung SMTB-DO Digital Output Terminal Board
  • Samsung SMTB-DI Digital Input Terminal Board
  • SAMSUNG SMBK-12 IOU Rack Backplane
  • SAMSUNG SMBK-08 IOU Rack Backplane
  • SAMSUNG SMPS-08 Rack Power Module
  • SAMSUNG SMCOM-08 Communication Expansion Card
  • SAMSUNG SMPI-8 Pulse Count Input Module
  • SAMSUNG SMTC-8 Thermocouple Input Module
  • SAMSUNG SMAOC-12 Analog Output Module (12CH)
  • SAMSUNG SMAOC-8 Analog Output Module (8CH)
  • SAMSUNG SMAIC-12 Analog Current Input Module (12CH)
  • SAMSUNG SMRTD-8 RTD Pt100 Temperature Input Module (8CH)