KONG -Y
NameDescriptionContent
Location:

Yokogawa FCN-100: Dual redundant configurable PLC/RTU

From: | Author:kongjiang | Time :2024-11-22 | 1097 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Yokogawa FCN-100: Dual redundant configurable PLC/RTU

High reliability is essential for the systems that control your critical processes.
The dual redundant model of the field control node (FCN) autonomous controller ensures that these processes continue without interruption even when a damaged module is replaced.

Exclusive features for FCN-100

Modular type PLC/RTU

Dual redundant configuration for CPU unit, power supply unit, and control networks

Information transmission package (InfoWell) available

For steady operations, high reliability is an essential requirement in the systems that controls and acquires data from various devices and processes and which interlink with other controllers in the control domain. The STARDOM autonomous controllers FCN-100 have rugged and highly reliable software and hardware, and as an optional feature support dual-redundant configurations for mission-critical applications.

Never Interrupts Your Process

High reliability is essential for the systems that control your critical processes. The dual redundant capability of the field control node (FCN) autonomous controller ensures that these processes continue without interruption even when a damaged module is replaced.

CPU unit, power supply unit, FOUNDATION™ fieldbus module, and control network can all be dual redundant.

Automatic switchover to stand-by CPU

Automatic data transfer from control side to replaced stand-by CPU

Hot-swappable modules including CPU and I/O modules

Fault-tolerant design (including ECC memory)

Durable Hardware

FCN-100 has a highly durable design. In addition to features such as fan-less cooling, there are no IC chips on the backplane, preventing mechanical failures. Furthermore, the use of error check and correct (ECC) memory* prevents software failures.

Secure control even in hazardous applications

FCN-100 has received ATEX type n certification, FM approval and CSA certification and provides safe and secure control even in hazardous applications. Optional corrosion-proof coatings are also available.

Advanced Self Diagnosis

Rich diagnostic functions make it possible to keep track of CPU temperature, SRAM memory status, and I/O module status. In addition to the diagnostic functions that are performed by the CPU, the analog input modules have embedded self diagnostic functions that can detect disconnected wires and short-circuits by continuously monitoring the loop status.

STARDOM capability of establishing connections to a various network types results in big cost reduction for the customers. Networkability of STARDOM autonomous controllers FCN-100 designed for the hazardous area shows absolute advantage in the various applications requiring remote monitoring and operation.

TCP/IP-based Redundant Network

A TCP/IP based network enables a seamless connection with control and information networks using COTS network components, and also allows the easy adaption of controllers for use with narrow bandwidth network infrastructure including public telephone lines, GSM/GPRS, satellite, and radio. The use of a redundant network configuration and data buffering guard against the loss of valuable data in the event of a disruption in network communications.

FCN-100 controller applications are written in programming languages compliant with the IEC 61131-3 international standard, so users do not need to learn manufacturer-specific programming languages and can start engineering immediately.

IEC 61131-3 Compliant Programming Languages

Concise applications can be developed by choosing the most suitable programming language for each application or the preference of the user from five IEC 61131-3 compliant languages including Function Block Diagram, Ladder Diagram, and Sequential Function Chart. Loop control and sequence control can be coded within the same environment, further improving engineering efficiency.

Reuse of Programs

Engineering efficiency is improved by reusing the programmed and verified applications by using the following methods.

Encapsulation
IEC 61131-3 compliant program allows your know-how to be encapsulated into reusable POU (Program Organization Units.) These POUs can be protected against user modification.

Network Template
Network Template, which is a code frame programmed by FBD, LD, ST or IL, makes reuse of program easier. Network Template is inserted into any applications and modified corresponding to applications.

Efficient Debugging

Software Wiring to Aid Debugging
Virtual wiring to input/output modules can be defined in the software, and so loop checks and testing of ladder sequences can be performed without actual inputs to the FCN-100 from a calibrator or test switches.

Simulator Functions for Efficient Development
The simulator functions simulate the control applications of the FCN-100 on a PC. Since this function does not require FCN-100 hardware, control applications can be developed simultaneously by two or more engineers. Alternatively, applications can be developed and debugged separately from applications running on FCN-100. 

Quick troubleshooting is the key to increasing the availability of the systems. From trouble shooting to the replacement of modules, STARDOM helps people on site perform simple maintenance procedures.

  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • ADLINK SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO  HSL-4XMO-TB-D103  HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • ADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840
  • Adlink PICMG Single Board Computers NuPRO-935A
  • ADLINK ADLINK NuPRO-841 REV:1.0 PICMG Single Board Computers
  • ADLINK PCI-8254 / PCI-8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NUPRO-780 PICMG Single Board Computers
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • Adlink Technology 51-37111-0C1 cPCI-R8217 cPCI-R3700A PCB Interface Card
  • ADLINK DPAC-3020-11(G) Embedded PC Automation Controller
  • ADLINK NuPRO-840 PICMG 1.0 industrial Single Board
  • Adlink 6U CompactPCI 2.0 Blades cPCI-6965
  • ADLINK PCI-9114DG Multi-Function DAQ Card
  • Adlink NuPRO-E43 PICMG Single Board Computers
  • Adlink PCI-7856 Distributed Motion Control
  • ADLINK Mini-ITX Embedded Boards MI-965
  • ADLINK NuPRO-E340 ICMG Single Board Computers
  • ADLINK NuPRO-595 Series Full-Size PICMG 1.0 SBC
  • ADLINK PCIe-GIE64+ / PCIe-GIE62+ 4 / 2-CH PCI Express® Power over Ethernet Frame Grabbers
  • ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC