Vibro-Meter I/O interface card IOC10 Mk2 (rear card) 600-046
I/O interface card IOC10 Mk2 (rear card) 600-046
DESCRIPTION (continued)
Different versions of the MPC4Mk2 + IOC4Mk2
module
The MPC4Mk2 + IOC4Mk2 machinery protection and
condition monitoring module is available in different
versions, as follows:
• MPC4Mk2 + IOC4Mk2 – this is the standard
version of the module, suitable for most
applications.
• MPC4Mk2 + IOC4Mk2 SIL – this is the SIL safety
version of the module, suitable for critical
applications demanding the highest level of
protection.
The MPC4Mk2 + IOC4Mk2 (standard) is the original
version of the module and supports all features and
processing functions.
The MPC4Mk2 SIL + IOC4Mk2 SIL is a version of the
module optimised for use in safety-related
applications (functional-safety contexts).
Accordingly, it has been designed in accordance with
the IEC 61508 “functional safety” standard and is
certified as SIL 2 capable by design.
In general, the MPC4Mk2 SIL + IOC4Mk2 SIL module
supports the same signal processing functions and
measurements as the MPC4Mk2 + IOC4Mk2
(standard) module but SIL versions of modules are
visually distinct and feature some important
differences in order to meet the strict requirements of
SIL safety systems.
For example, the MPC4Mk2 SIL module uses three
electronics processing modules in order to help
ensure that measurements can always be trusted
(compared to one processing module for the
MPC4Mk2 module) and offers more complete
separation of machinery protection system (MPS)
and condition monitoring system (CMS) functionality
so that the safety function is never compromised. The
MPC4Mk2 SIL also includes more comprehensive
diagnostics (BIST). For a more detailed comparison,
see Differences between standard and SIL
versions of the VM600Mk2 MPC4Mk2 +
IOC4Mk2 (and RLC16Mk2) modules starting on
page 6.
| Honeywell | CC-PAIH02 |
| YOKOGAWA | YTA110 |
| STUCKE | SYMAP-BCG 4512 24/1A/PT400V/D1/GC1/G1V400/RU0/C2/0/4/1/2 |
| METSO | ND9106HNT |
| HIRSCHMANN | MM20-Z6Z6Z6Z6SBHH |
| GE | FLC48SXC8V11A |
| Alstom | 29.144463 |
| Woodward | UG‐25+ 8528-300 |
| METSO | XWB11283-900N12 |
| WESTRONICS | SBGA-15P1WM |
| EMERSON | FSFB-S600+ S600P1-0-B-0-0-1 |
| GE | IS200EDISG1AAA |
| Prosoft | RLX2-IFH24E |
| GE | MM300-G-E-H-C-1-C-A-C-C-X-X-B-E |
| ABB | CM15/000S0E0/STD |
| Alstom | 29.139692 |
| Woodward | 8440-1575 |
| EPRO | PR6423/11R-131+CON041 |
| Foxboro | IGP10-T22D2E-M3A2 |
| GE | 850-E-P5-NN-G5-L-C-N-A-A-N-M-A-S-F-C-SE-N-N-B-4 |
| EATON | XVS-440-57MPI-1-10 |
| Alstom | 20X1310CRL |
| Alstom | KCC8302 |
| ABB | MCU2A02V2-4 ISCA022657R9090 |
| WOODWARD | 8440-1706 SPM-D11 |
In addition, some versions of VM600Mk2 modules are
also available with a conformal coating in order to
provide additional environmental protection
Either one or two VM600Mk2/ VM600 RPS6U rack
power supplies can be installed in a VM600Mk2/
VM600 ABE04x system rack. A rack with one
RPS6U power supply (330 W version) supports the
power requirements for a full rack of modules
(cards) in applications with operating
temperatures up to 50 °C (122 °F).
Alternatively, a rack can have two RPS6U power
supplies installed in order to either support rack
power supply redundancy or in order to supply
power to the modules (cards) non-redundantly
over a wider range of environmental conditions.
A VM600Mk2/ VM600 ABE04x system rack with two
RPS6U power supplies installed can operate
redundantly (that is, with rack power supply
redundancy) for a full rack of modules (cards).
This means that if one RPS6U fails, the other will
provide 100 % of the rack’s power requirement so
that the rack will continue to operate, thereby
increasing the availability of the machinery
monitoring system.
Note: This is known as a redundant RPS6U rack
power supply configuration.
A VM600Mk2/ VM600 ABE04x system rack with two
RPS6U power supplies installed can also operate
non-redundantly (that is, without rack power
supply redundancy). Typically, this is only
necessary for a full rack of modules (cards) in
applications with operating temperatures above
50 °C (122 °F), where RPS6U output power derating
is required.
Note: Even though two RPS6U rack power supplies
are installed in the rack, this is not a redundant
RPS6U rack power supply configuration