Woodward: easYgen-3500XT (P1)   8440-2085


Product number: 8440-2085

Manufacturer product number: 8440-2085

Description: Woodward: easYgen-3500XT (P1), Genset Controller, 1A/5A,

Output Type/Preset Description

Relay output [R 01] Programmable

Fixed to "Ready for operation"

CAUTION! Only relay [R 01] has an

inverse logic. The relay opens (all other

relays close), if the logical output of the

LogicsManager becomes TRUE.

This discrete output is used to ensure that the internal functions

of the controller are operating properly.

It is possible to configure additional events, which cause the con

tacts of this discrete output to open, using the LogicsManager.

Relay output [R 02] Programmable

Preconfigured to "Centralized alarm (horn)"

When a centralized alarm is issued, this discrete output is ena

bled.

A horn or a buzzer maybe activated via this discrete output.

Pressing the button next to the "3" symbol will acknowledge the

centralized alarm and disable this discrete output.

The discrete output will re-enable if a new fault condition resulting

in a centralized alarm occurs. The centralized alarm is initiated by

class B alarms or higher.

Relay output [R 03] Programmable

Preconfigured to "Starter"

The generator starting circuit is engaged when this discrete

output is enabled.

This discrete output will enable depending on the start sequence

(refer to the start sequence description in Ä Chapter 4.5.9.1

“Engine Type” on page 219) to energize the starter for the config

ured starter time (parameter 3306 Ä p. 227).

Relay output [R 04] Programmable

Preconfigured to "Fuel solenoid / gas

valve"

Fuel solenoid

The fuel solenoid for the diesel engine is energized when this dis

crete output is enabled. If the engine is given a stop command or

engine speed drops below the configured firing speed, this dis

crete output is disabled immediately.

Gas valve

The gas valve for the engine is energized when this discrete

output is enabled. If the engine is given a stop command or

engine speed drops below the configured firing speed, this dis

crete output is disabled immediately.

Relay output [R 05] Fixed

Preconfigured to "Command: open MCB"

Only applicable for application mode .

The controller enables this discrete output when the MCB is to be

opened for switching operations.

If the discrete input "Reply MCB" is energized, the discrete output

"Command: open MCB" is disabled

Output Type/Preset Description

Relay output [R 06] Fixed

Preconfigured to "Command: close GCB"

Only applicable for application modes  and .

The "Command: close GCB" output issues the signal for the GCB

to close. This relay may be configured as an impulse or constant

output signal depending on parameter 3414 Ä p. 194.

Impulse

If the output is configured as "Impulse", the discrete output will

enable for the time configured in parameter 3416 Ä p. 194). An

external holding coil and sealing contacts must be installed into

the GCB closing circuit if this discrete output is configured for an

impulse output signal.

Constant

If the relay is configured as "Constant", the relay will energize and

remain enabled as long as the discrete input "Reply GCB"

remains de-energized and the generator and busbar voltages are

identical. If a class C or higher alarm occurs, this discrete will dis

able and the GCB will open immediately.

Relay output [R 07] Fixed

Preconfigured to "Command: open GCB"

Not applicable for application mode

The parameter 3403 Ä p. 194 defines how this relay functions.

If this output is configured as "N.O.", the relay contacts close

resulting in the GCB opening circuit energizing.

If this output is configured as "N.C.", the relay contacts open

resulting in the GCB opening circuit de-energizing.

If the controller is configured for the breaker application "None",

this relay is freely configurable.

Application mode

The open GCB command remains enabled until the GCB is man

ually closed and the discrete input "Reply GCB" is energized. The

open GCB command will be issued when a fault condition or an

engine shut down occurs.

Application mode  or

The controller enables the open GCB command when the GCB is

to be opened for switching operations. If the discrete input "Reply

GCB" is energized, the open GCB command will be disabled.

Relay output [R 08] Fixed

Preconfigured to "Command: close MCB"

Only applicable for application mode

The discrete output "Command: close MCB" is an impulse output

signal.

ABBTP854
ABBD2D146-AA28-28
ABBDSMB-02C
ABBFS450R12KE3/AGDR-71C
ABBPNI800
ABBCTB810,HN800
ABBPNI800 MB805
ABBDSAO120
ABBREA101-AAA
ABBTB850
ABBDI810
ABBINSEM01
ABBPM645B
ABBPFEA111-65
ABBDSQC355A
ABBAI801
ABBAFC094AE02
ABBSPBRC400
ABBPPC380AE01
ABB3HAC026271-001/DSQC646

This discrete output is enabled for the time configured in param

eter 3417 Ä p. 197.

An external holding coil and sealing contacts must be utilized with

the MCB closing circuit.

Relay output [R 09] Programmable

Preconfigured to "Stop solenoid"

Only applicable for application mode .

Inverted function of Fuel solenoid / gas valve (preconfigured [R4])

Relay output [R 10] Programmable

Preconfigured to "Auxiliary services"

The auxiliary services output (LogicsManager 03.01) will be ena

bled with the start command (prior to the engine start because of

the prerun time) and remains enabled as long as the engine is

running.

It w

Configure Monitoring

4.4.1 Generator

ID Parameter CL Setting range

[Default]

Description

1770 Generator

voltage moni

toring

2 The unit can either monitor the phase-neutral (wye) voltages or the phase

phase (delta) voltages.

If the controller is used in a compensated or isolated network, voltage protec

tion monitoring should be configured as phase-neutral to prevent earth-faults

resulting in tripping of the voltage protections.

[Phase

phase]

The phase-phase voltage will be monitored and all subsequent parameters

concerning voltage monitoring "generator" are referred to this value (VL-L).

Phase - neutral The phase-neutral voltage will be monitored and all subsequent parameters

concerning voltage monitoring "generator" are referred to this value (VL-N).

Notes

WARNING: This parameter defines how the protective functions operate



  • ADLINK cPCI-8168 Advanced 6U CompactPCI 8-axis Motion Controller with One HSL Network
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Centralized Motion Controllers PCI-8254/8258
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3o
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output