KONG -Y
NameDescriptionContent
Location:
product
Woodward: easYgen-3400XT (P2), Genset Controller 1A/5A  8440-2087
❤ Add to collection

Woodward: easYgen-3400XT (P2), Genset Controller 1A/5A 8440-2087

Woodward: easYgen-3400XT (P2), Genset Controller 1A/5A  8440-2087


















U.S.$35720.00
U.S.$29620.00
U.S.$28139.00
U.S.$27546.60
Weight:1.290KG
Quantity:
(Inventory: 1)
Buy now
Add to cart
Description

Woodward: easYgen-3400XT (P2), Genset Controller 1A/5A  8440-2087



















Product number: 8440-2087

Manufacturer product number: 8440-2087

Description: Woodward: easYgen-3400XT (P2), Genset Controller 1A/5A

The discrete inputs may be grouped into two categories:

n Programmable–The discrete input has been assigned a default function

using either the LogicsManager or preconfigured alarms

such as "emergency stop".– The following sections describe how these functions are

assigned.– The function of a discrete input can be changed if required.– The following description of the inputs, labeled with "pro

grammable", refers to the preconfiguration.

n Fixed– The discrete input has a specific function that cannot be

changed depending upon the configured application mode.

Input Type/Preset Description

Discrete input [DI 01] Programmable

Preconfigured to "Emergency stop"

This discrete input is configured as alarm class F and is not

delayed by the engine speed.

Discrete input [DI 02] Programmable

Preconfigured to "Start in AUTO"

Enabled in the AUTOMATIC operation mode

This discrete input is configured as a Control input in the alarm

class and is not delayed by the engine speed.

n Energized

If the unit is in the AUTOMATIC operation

mode (selected with the operating mode selec

tion push button on the front panel) the con

trolled engine is started automatically.

n De-energized

The engine is stopped.

Discrete input [DI 03] Programmable

Preconfigured to "Low oil pressure"

This discrete input is configured as alarm class B and is

delayed by the engine speed.

Discrete input [DI 04] Programmable

Preconfigured to "Coolant temperature"

This discrete input is configured as alarm class B and is not

delayed by the engine speed.

Discrete input [DI 05] Programmable

Preconfigured to "Alarm acknowledge"

This discrete input is used as a remote acknowledgement for

alarms. The input is normally de-energized. When an alarm is

to be acknowledged the input is energized. The first time an

alarm in acknowledged, the centralized alarm/horn is silenced.

When the input is energized a second time, all alarms, which

are no longer active, will be acknowledged.

This discrete input is configured as a Control input in the alarm

class and is not delayed by the engine speed.

Discrete input [DI 06] Programmable

Preconfigured to "Enable MCB"

Only applicable for application mode

This discrete input is configured as a Control input in the alarm

class and is not delayed by the engine speed.

n Energized

The MCB is enabled and closure of the

breaker is permitted.

n De-energized

The MCB is not enabled and closure of the

breaker is not permitted. This function permits

a supervisory control (i.e. a PLC) to allow the

closure of the MCB by the easYgen.

Discrete input [DI 07] Fixed to "Reply: MCB open" Only applicable for application mode

This input implements negative function logic.

The controller utilizes the CB auxiliary (B) contacts into this dis

crete input to reflect the state of the MCB.

This discrete input must be energized to show when the

breaker is open and de-energized to show when the MCB is

closed. The status of the MCB is displayed on the screen.

This input is usually used in all breaker modes to change

between frequency/voltage and power/power factor control

(refer to note below).

Discrete input [DI 08] Fixed to "Reply: GCB open" Only applicable for application modes  and

This input implements negative function logic.

The controller utilizes the CB auxiliary (B) contacts into this dis

crete input to reflect the state of the GCB. This discrete input

must be energized to show when the breaker is open and de

energized to show when the GCB is closed. The status of the

GCB is displayed on the screen.

This input is usually used in all breaker modes to enable

reverse power protection, overload MOP protection, mains

decoupling and the activation of the load sharing (refer to note

below).

Discrete input [DI 09] Programmable

Preconfigured for "Alarm class B"

This discrete input is not delayed by the engine speed.

Discrete input [DI 10] Programmable

Preconfigured for "Alarm class B"

This discrete input is not delayed by the engine speed

n Programmable– The discrete output has been assigned a default function

using the LogicsManager.– The following text describes how these functions are

assigned using the LogicsManager.– It is possible to change the function of the discrete output if

required.– The following description of the outputs, labeled with "pro

grammable", refers to the preconfiguration.

n Fixed– The discrete output has a specific function that cannot be

changed depending upon the configured application mode.– The discrete output cannot be viewed or changed in the

LogicsManager.– However, the discrete output may be programmable in

some application modes.

ABBTHYRISTOR MODUL   WE-73-10/CH 64421956
ABB969.105EBG   540KKS166899
ABB3BHE024577R0101   PPC907BE AMC34
ABBCH-3185   3BHL000986P1006
ABB500MBA01   1MRB150003R0002 1MRB200053/L
ABB500MBA02   1MRB150003R000/B
ABB500MBA02   1MRB150003R0003 1MRB200053/M
ABB3BHE022294R0103   GFD233A103
ABB3BHE023784R1023   PP D113  B01-10-150000
ABB4LA41100102V1.2   KB2
ABB3BSE076940R1   PM862K01 AC 800M
ABB560PSU02   1KGT011900R0001
ABBPPD113   B03-23-100110 3BHE023584R2334
ABBXFD213A   3BHE028122R0001
ABBPFVO102  PFVO142 3BSE023732R1
ABBPM891   3BSE053240R1
ABBPPD513A0E110110   3BHE039724R0E41
ABBREF630   1KHL160003R0001CR


  • ADLINK cPCI-8168 Advanced 6U CompactPCI 8-axis Motion Controller with One HSL Network
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Centralized Motion Controllers PCI-8254/8258
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3o
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output