Description
DS200TCEBG1A

Part Number DS200TCEBG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockThe Mark V Speedtronic DS200TCEBG1A is a Common circuit EOS card which is known as Protective Termination Expander Board.The DS200TCEBG1A has four signal transformers,three bayonet connectors,one 26 pin connector,four 10 pin connectors and three 20 pin connectors.The DS200TCEBG1A holds the alarm horn for Mark V LM, The board has an audible alarm.The Mark V DS200TCEBG1A is located in location 2 of core.Always adhere to the manufactures installation guidelines while installing or replacing the board.COMMON CIRCUITS EOS

Technical specification of DS200TCEBG1A

Original manufacturer general electric company

Product series logo v

Functional part number DS200TCEBG1A

Function description protection terminal expansion board

Functional abbreviations

PCB coating type common coating

First functional revision a

About DS200TCEBG1A

As mentioned earlier, the DS200TCEBG1A printed circuit board was originally manufactured for the Mark V turbine control system series of General Electric Company. Mark V series, to which DS200TCEBG1A belongs, as you may know from its extended series name, has specific application in the control and management system of compatible automatic drive components of wind, steam and gas turbines, and it is regarded as the legacy series of General Electric because it finally stopped production within a few years after its initial release. Although the Mark V turbine control system series of DS200TCEBG1A board is a traditional series, it is also one of the final Mark product series of General Electric Company using the patented technology of Speedtronic control system. Although the PCB with this function originally produced in Mark V series is the DS200TCEBG1A protection terminal extension board, it is indeed easier to define the DS200TCEBG1A printed circuit board as the protection terminal extension board through its official functional product description.

Hardware tips and specifications

Like any product of Mark V turbine control system series of General Electric Company, DS200TCEBG1A printed circuit board adopts its own necessary function series-supporting and introducing hardware components. GE protection terminal extension board DS200TCEBG1A has three bayonet connectors, four signal transformers and one 26-pin connector. It also includes four 10-pin connectors and three 20-pin connectors. Because the extension board DS200TCEBG1A of GE protection terminal is equipped with many heavy components, it is designed with 8 screw holes to support the weight of the board when it is installed in the driver. The components of the DS200TCEBG1A protection terminal expansion board are also filled with various voltage limiting hardware components standardized to Mark V series. Includes resistors, diodes, capacitors and integrated circuits, as described in the DS200TCEBG1A instruction manual attached above. As stated in the above-mentioned DS200TCEBG1A instruction manual, the DS200TCEBG1A PCB does not provide hardware components for software or hardware configuration, but provides a series of connectors that are very important for the Mark V series interface. Some specific connectors in the DS200TCEBG1A PCB assembly include connectors with factory printed naming labels JKX/Y/Z, JMP, JU, JV, JVA, JWX/Y/Z, JPU, JPV and JPW. Except for the last three JPU, JPV and JPW connectors, the specific functions of all these connectors in the DS200TCEBG1A board and its greater Mark V series automatic drive components are included in the above-mentioned DS200TCEBG1A data sheet. These connectors are not named by function because they exist as residual structures and are usually not used during the normal operation of DS200TCEBG1A products.

Before starting to dismantle the old DS200TCEBG1A board, please pay attention to the installation position of the old board and plan to install the replacement board at the same position. Also pay attention to the connection position of cables in the greater Mark V series automatic driver of DS200TCEBG1A PCB, and create a label or mark on the circuit board to indicate the ID of the connector it is connected to. You can only disconnect cables when you record where they are connected to the new board. Use a screwdriver to unscrew the screws that secure the DS200TCEBG1A PCB in the driver. Turn the screwdriver with one hand and support the plate in the driver with the other. Keep all removed screws and washers. If any screws fall into the bottom inside the drive, please remove the hardware before continuing. Loose screws may contact electrical components of DS200TCEBG1A, resulting in short circuit, electric shock or fire. If additional maintenance is required, this may cause personal injury or extend the downtime of the drive. If the screw gets stuck in the moving parts, it may prevent the parts from moving freely and cause damage to the motor or other parts.


  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • Reason RT431 GPS Precision-Time Clock GE
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch
  • GE Reason S20 Managed Ethernet Switches
  • GE Gridcom DIP.net
  • Central Control Station at Jaenschwalde mineLausitzer Braunkohle AG, Germany 2000
  • ABB Ability™ System 800xA Advant® Master S400 I/O to S800 I/O Evolution
  • ABB with Advant Controller 400 series
  • Advant™Automation with MOD 300™ Software
  • Bently 2300/20 and 2300/25 2300 Vibration Monitors
  • ABB NGC8206 Natural Gas Chromatograph Dual Unit
  • MOTOROLA MVME2400 TM VME Processor Modules
  • 5320 Series Foxboro DCS Control Network Ethernet Equipment
  • ExtremeSwitching™ 5420 Series
  • WOODWARD EGCP-3 Engine Generator Control Package LS (Load Sharing)
  • 5520 Series Universal Edge/Aggregation-Switch Platform
  • X440-G2 Series
  • EMERSON FloBoss™ S600 Flow Manager Specification Sheet
  • KONGSBERG RAIV400 Remote Analogue Input, Voltage
  • RMP420-Remote Multipurpose Input/Output Kongsberg
  • 610 serie ABB Feeder Protection REF610 Product Guide
  • Triconex 3351S2 Controller Features
  • HBRF Megamax – Emax2 Air Circuit Breaker ABB
  • ABB MEASUREMENT & ANALYTICS | DATA SHEET LS4000 Diode laser analyzer
  • Pressductor Pillowblock Load Cells Vertical Measuring PFCL 201 User manual
  • PARKER BFR5K Series
  • AC 900F controller ABB
  • Uniop ePAD05 and ePAD06 Technical description
  • Hitachi ABB Communication Unit 560CMR02
  • MOTOROLA MVME5500 Series VME Single-Board Computer
  • ABB Symphony Plus SD Series HPC800 controller
  • ABB AC800M Controller Hardware System
  • ABB AC800M PROFIBUS DP Installation System
  • ABB Freelance 800F AC800F Control systems
  • ABB Compact control system replaces PLC AC700F
  • abb Triguard SC300E 3BNP004720R101 TMR Safety Products
  • ABB Distributed busbar protection REB500
  • ABB Advant Controller 400 series
  • ABB MEASUREMENT & ANALYTICS | PRODUCT GUIDE
  • PACIFIC SCIENTIFIC PC800 PC832 PC830 Series Digital Brushless Servo Drive
  • PSS41S-3FDCTSAA Triconex DCS System Access Application Driver for Field Device Controller 280
  • Alstom controller of ICP232 029.359325
  • DEIF DU-2/MKIII Paralleling And Protection Unit General information
  • ABB 3ADT220134R0001 SDCS-COM-81 board 10MBd
  • ABB 3BHB006338R0002 UNS 0881a-P,V2:GDI PCB assembled *PB
  • ABB GRID BREAKER UNIT GBU72 3BHE055094R0002 / 3BHE031197R0001 / 3BHB030310R0001
  • ABB PCS6000 PRODUCT FAMLIY
  • ALSTOM SPU232.2 controller UNIT 029.366 817 029366817 SPU2322
  • ABB AO2000-LS25 Operator’s Manual 41/24-109 EN Rev. 3
  • Alstom EPSD-0603 series Circuit board redundancy architecture
  • ABB GJR2390200R1411 83SR04R1411 Control Module Universal
  • GE Digital Energy Hydran 201Ti Mark IV Essential DGA monitoring
  • Bender ISOMETER®IRDH275 IRDH275B
  • ABB 3BSE017235R1 PXAH 401 Operator Unit
  • HIMax-TECHNICALFACTS
  • Power supply CP-E 24/1.25 ABB
  • ABB NSIN0070-5 (IP23) 3ABD00024914
  • ABB 1VCR000993G0002 PCB card
  • ABB 2CSG524000R2021 TMD-T4/96 Temperature control unit
  • 3BHE014135R0011 UAD149A0011 ABB AC800PEC series
  • Alstom CT94360/01 signal regulator
  • MISP2-2W-T00-1000 GE Measurement & Control Solutions
  • DEIF AGC150 independent generator controller
  • DEIF AGC-4 10102264.10 Advanced generator set controller
  • ABB Plantguard Communications P8151B P8110B
  • ABB Plantguard series P8403 Digital input module
  • ABB 3BHE041343R0102 PCD530A102 Comm. Contr. & Meas. (CCM)
  • ABB P8431 TMR analog input module
  • ABB P129740-002 SIO Assembly,Smart Weight,Interface,Pre-