KONG -Y
NameDescriptionContent
Location:
product
DS200TCPDG2B Distribution circuit board
❤ Add to collection

DS200TCPDG2B Distribution circuit board

DS200TCPDG2B
U.S.$26150.00
U.S.$18025.00
U.S.$17123.75
U.S.$16763.25
Weight:1.280KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
DS200TCPDG2B

Part Number DS200TCPDG2B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockThe DS200TCPDG2B is a power distribution circuit board developed by GE. The 125 V dc power is distributed to the TCPS boards in each IO core, the Control Engine core, and the TCEA boards in the P1 core by the Power Distribution Board (TCPD), which is located in PD. The TCPD board includes switches for individually powering down each core. The digital I/O cores (Q11, Q21, and Q51) are not powered directly by PD; instead, they are powered by their associated IO core. The TCPD board powers the DTBC and DTBD (solenoid output power) terminal boards in the digital cores. The TCPD board supplies the 120/240 V ac power for the ignition transformers connected to DTBC. The CTBA terminal board in the R5 receives power from the TCPD to monitor PD power output. DS200TCPDG2B Configuration Hardware: On systems with an external reference, the BJS hardware jumper is provided to isolate the ground reference. When the jumper is inserted, the external reference systems are given a ground reference. Software: The TCPD board has no software configuration. DS200TCPDG2B Switches Several switches are connected to the TCPD board. Each switch toggles the power for the specific core or board associated with it on and off. SW1 - Controls the power in the R1 core. SW2 - Controls the power in the R2 core. SW3 - Changes the power of the R3 core. SW4 - Changes the power of the R5 core. SW5 - Changes the power in the R core. SW6 - Changes the power on X in the P1 core. SW7 - Changes the power on Y in the P1 core. SW8 - Changes the power on Z in the P1 core. DS200TCPDG2B Power External 115/230 V ac power and 125 V dc power are fed into the TCPD board via TB1, which is mounted on the PD core and hard wired to it. If ac power is supplied, it is converted to 125 V dc via the JZ2 connector in a DACA (ac to DC). The connectors listed above are used to distribute power from PD to the various cores and boards. For applications requiring lower voltages for contact #18 on the DTBC board in the Q51 core, an optional JZ3 connection is available. Power is additionally conditioned across resistors via the JZ1 connector before being distributed to the TCEA boards in the P1 core. If ac power is available, the JZ5 connector supplies it to the ignition transformer outputs. DS200TCPDG2B Connectors J1R - Distributes 125 V dc power to the R1 core's TCPS board. J1S - Distributes 125 V dc power to the R2 core's TCPS board. J1T - Distributes 125 V dc power to the R3 core's TCPS board. J1C - Distributes 125 V dc power to the R5 core's TCPS board. J1D - Distributes 125 V dc power to the R core's TCPS board. J7W - Distributes 125 V dc power to the P1 core's TCTG board. J7X - Distributes 125 V dc power to the TCEA board in P1 core location one, X. J7Z - Distributes 125 V dc power to the TCEA board in P1 core location five, Z. J8A - Provides the DTBC board in the Q51 core with 125 V dc power for the solenoids. J8B - Distributes the 125 V dc power for the solenoids to the DTBD board in the Q51 core. J8C - Provides the DTBC board in the Q11 core with 125 V dc power for the solenoids. J8D - Distributes the 125 V dc power to the solenoids via the DTBD board in the Q11 core. J12A - Distributes 125 V dc power to the Q51 core's DTBA board for the wetted contact inputs. J12B - Provides the DTBA board in the Q11 core with 125 V dc power for the wetted contact inputs. J15 - Not commonly used. J16 - Not commonly used. J19 - Not commonly used. J20 - Not commonly used. JPD - In R5, distributes power to CTBA. R5 uses this to monitor the PD ac and DC power output. JZ1 - TCEA board and contact input power drop across external resistors connection. JZ2 - Incoming ac from the TB1 terminal board connected to the DACA (ac to DC converter) via the DACA box's JZ connector. Used for converting alternating current to direct current. JZ3 - Substitute for JZ2 if a lower voltage is required for a special contact output circuit (contact output #18 on the Q51's DTBC board). JZ4 - Auxiliary alternating current source connection point for applications requiring an isolated input for an uninterruptible power source connection(s) and/or switched backup power source. Usually applied to a Black Start Inverter. JZ5 - The ignition transformers' standard ac power source connection. J2R - Not commonly used. J2S - Not commonly used. J2T - Not commonly used. J7A - Not commonly used. J12C - Not commonly used. J17 - Not commonly used. J18 - Not commonly used. Installation The signal wire terminals are described in the installation instructions that came with the original board from the manufacturer. This explains what each terminal does and how to connect signal wires to it. It specifies whether the terminal receives or transmits signals from another board, for example. It also specifies the type of data conveyed by signal wires connected to it. It is not essential to determine which signal wires to connect to the terminals while replacing the board. All the installer has to do on the replacement board is connect the identical wires to the same terminals. Examine the signal wire terminals first, noting that each one is labeled with an ID. AC1N, AC1H, AC2N, and AC2H are the IDs. Each wire should be labeled with the ID of the terminal to which it is connected. Use a tag that won't come off the wire easily. It is not essential to determine which signal wires to connect to the terminals while replacing the board. All the installer has to do on the replacement board is connect the identical wires to the same terminals. Examine the signal wire terminals first, noting that each one is labeled with an ID. AC1N, AC1H, AC2N, and AC2H are the IDs. Each wire should be labeled with the ID of the terminal to which it is connected. Use a tag that won't come off the wire easily. A screw holds the wires in place in the termination. To liberate the signal wire, unscrew the screw with a screwdriver. Carry out the same procedure with all of the signal wires connected to the terminals. When you're ready to install the signal wires, unscrew the screws on the terminals first. The cables should then be inserted and the screws tightened. To make sure the signal wire is secure, gently tug on it.POWER DISTRIBUTION M

DS200DCFBG1BLC

MS90376-12Y

VMIVME-7807RC

SERVOSTAR 310

IS200ERIOH1AAA

IS220PSCAH1A 336A4940CSP9

D20-PS LFDSC143-4000

IS200TDBTH6ABC

DS200SHVMG1AGE

IS2020RKPSG3A

DS200SHVMG1AFE

IC660ELB912

IS220PPRFH1A

IC698PSA350

HYDRAN M2

IC693PWR321

IS215VCMIH2BB IS200VCMIH2BCC

  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives