HIMA   F60DIO24/1601 Safety-Related Controller
❤ Add to collection

HIMA F60DIO24/1601 Safety-Related Controller

HIMA   F60DIO24/1601 Safety-Related Controller

U.S.$45477.00
U.S.$38760.00
U.S.$36822.00
U.S.$36046.80
Weight:1.290KG
Quantity:
(Inventory: 1)
Buy now
Add to cart
Description

HIMA   F60DIO24/1601 Safety-Related Controller


Configuring the System ID and the Connection Parameters

To configuring the system ID and the connection parameters

1. Select the resource in the structure tree.

2. Click the Online button located on the Action Bar or select Online on the context menu.

The System Login dialog box is displayed.

3. Click Search.

The Search per MAC dialog box appears.

4. Enter the MAC address valid for the controller - see the label on the housing - and click

Search.

In the dialog box, the values set for IP address, subnet mask and S:R:S are

displayed.

5. If the values for the project are not correct, click Change.

The Write via MAC dialog box appears.

6. Type correct values for the connection parameters and the S.R.S., and enter the access

data for a user account with administrator rigths valid on the controller. Click Write.

Connection data and S.R.S are configured and it is now possible to log in.

For further details, refer to the SILworX manual First Steps (HI 801 103 E).

Loading a Resource Configuration after a Reset

If the compact system is switched on with engaged reset key, it restarts and resets the

connections parameters and user account to the default values (only in case of a

controller). After a new restart with disengaged reset key, the original values are used.

If the connection parameters were modified in the user program, they can be configured in

the compact systems such as described in Chapter 8.2.6.

Logging in as Default User

After configuring the connection parameters and prior to loading the user program, the

default user (administrator with empty password) must be used in the following cases:

The password for the user account is no longer known.

A new user account should be used in the project.

To log in as default user

1. Select the resource in the structure tree.

2. Click the Online button located on the Action Bar or select Online on the context menu.

The System Login dialog box opens.

3. In the IP Address field, select the correct address or use the MAC address.

4. Enter Administrator in the User Group field.

5. Let the Password field empty or cancel the password.

6. Select Administrator in the Access Mode field.

7. Click Log-in.

SILworX isconnected to the HIMatrix controller with default user rights.

Use+A in the System Login dialog box to skip steps 4-6!

8.2.8

8.2.9

Loading a Resource Configuration from the PADT

Before a user program can be loaded with the connection parameters (IP address, subnet

mask and system ID) into the controller, the code must have been generated for the

resource, and ´the connection parameters for PADT and resource must be valid, see

Chapter 8.2.6.

To load a resource configuration from the PADT

1. Select a resource in the structure tree.

2. Click the Online button located on the Action Bar or select Online on the context menu.

3. In the System Login dialog box, enter a user group with administrator rights or write

access.

The Control Panel appears in the workspace and displays the controller state.

4. In the Online menu, select Resource Download.

The Resource Download dialog box appears.

5. Click OK to confirm the download.

SILworX loads the configuration into the controller.

6. Upon completion of the loading procedure, click the Resource Cold Start function on the

Online menu to start the user program.

After the cold start, System State and Program Status enter the RUN state.

The resource configuration is loaded from the PADT.

The Start, Stop and Load functions are also available as symbols on the Symbol Bar.

Loading a Resource Configuration from the Flash Memory of the

Communication System

If data errors were detected in the NVRAM thus causing the watchdog time to be exceeded,

it can be useful to load the resource configuration from the flash memory for the

communication system instead of from the PADT:

If the Control Panel (CP) is no longer accessible, the connection parameters for the project

must be reset in the controller, see Chapter 8.2.6.

If the controller adopts the STOP/VALID CONFIGURATION state after restarting, the user

program can again be started.

If the controller adopts the STOP/INVALID CONFIGURATION state after restarting, the

user program must be reloaded into the NVRAM.

Use the Load Configuration from Flash command to read a backup copy of the last

executable configuration from the flash memory for the communication system transfer it to

HIMAF8620/11
HIMAELOPII
HIMAF7131   981713102
HIMAF8621A   984862160
HIMAH51q-HS   B5233-1 997105233
HIMAF3322
HIMAF7133
HIMAZ7136
HIMAZ7126
HIMAK9203A   996920360
HIMAF6705
HIMABV7032-0,5
HIMAEABT3   B9302 997009302
HIMAF8627
HIMAF7533
HIMAF3231




  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • Reason RT431 GPS Precision-Time Clock GE
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch