KONG -Y
NameDescriptionContent
Location:
product
HIMA  F60DO801  Safety-Related Controller
❤ Add to collection

HIMA F60DO801 Safety-Related Controller

HIMA  F60DO801  Safety-Related Controller

U.S.$35477.00
U.S.$32760.00
U.S.$31122.00
U.S.$30466.80
Weight:1.290KG
Quantity:
(Inventory: 99999)
Buy now
Add to cart
Description

HIMA  F60DO801  Safety-Related Controller


Configuring the Ethernet Interfaces

Ethernet interfaces are configured in the Detail View of the communication system. If the

remote I/Os have no communication system, the Ethernet interfaces are configured in the

Detail View of the processor system. Refer to the manuals of the HIMatrix controllers and

remote I/Os for more details.

Configuring the User Program

The following user program switches and parameters can be set in the Properties dialog

box of the user program:

To access the system variables for input and output channels

1. Display the desired resource in the Hardware Editor.

2.  Double-click the required input or output module to open the corresponding Detail View.

3. In the Detail View, open the tab with the required channels.

The system variables for the channels appear.

Use of Digital Inputs

Perform the following steps to use the value of a digital input in the user program

1. Define a global variable of type BOOL.

2. Enter an appropriate value, when defining the global variable.

3. Assign the global variable to the channel value of the input.

4

In the user program, program a safety-related fault reaction using the error code -> Error

Code [Byte].

The global variable provides values to the user program.

For digital input channels for proximity switch internally operating in analog mode, the raw

value can also be used and the safe value can be calculated in the user program. For more

information, see below.

To get additional options for programming fault reactions in the user program, assign global

variable to DI.Error Code and Module Error Code. For more information on the error codes,

refer to the manual of the corresponding compact system or module.

Use of Analog Inputs

Analog input channels convert the measured input currents into a value of type INT (double

integer). This value is then made available to the user program. With analog inputs of type

FS1000. the range of values is 0...1 000. with analog inputs of type FS2000. the range of

values is 0...2 000.

The safety-related precision is the guaranteed accuracy of the analog input without fault

reaction. This value must be taken into account when configuring the safety functions.

Perform the following steps to use the value of an analog input in the user program

1

Define a global variable of type INT.

2. Enter an appropriate value, when defining the global variable.

3

Assign the global variable to the channel value -> Value [INT] of the input.

4. In the user program, define a global variable of the type needed.

5. In the user program, program a suitable conversion function to convert the raw value

into a used type and consider the measurement range.

6. In the user program, program a safety-related fault reaction using the error code -> Error

Code [Byte].

The user program can process the measuring in a safety-related manner.

If the value 0 for a channel is within the valid measuring range, the user program must, at a

minimum, evaluate the parameter Error Code [Byte] in addition to the process value.

To get additional options for programming fault reactions in the user program, assign global

variable to AI.Error Code and Module Error Code. For more information on the error codes,

refer to the manual of the corresponding compact system or module.

Use of Safety-Related Counter Inputs

The counter reading or the rotation speed/frequency can be used as an integer value or as

a scaled floating-point value.

In the following sections, xx refers to the corresponding channel number.

Perform the following steps to use the integer value

1. Define a global variable of type UDINT.

2. Enter an appropriate value, when defining the global variable.

3

Assign the global variable to the integer value Counter[xx].Value of the input.

4. In the user program, program a safety-related fault reaction using the error code

Counter[xx].Error Code.

The global variable provides values to the user program.

To get additional options for programming fault reactions in the user program, assign global

variable to Counter.Error Code and Module Error Code. Refer to the manual of the compact

system or module for more details on how to use the error codes and other parameters of

the counter input.

Use of Digital Outputs

Perform the following steps to write a value in the user program to a digital output

1. Define a global variable of type BOOL containing the value to be output.

2. Enter an appropriate value, when defining the global variable.

3. Assign the global variable the Value [BOOL] -> channel value of the output.

4

In the user program, program a safety-related fault reaction using the error code -> Error

Code [Byte].

The global variable provides values to the digital output.

To get additional options for programming fault reactions in the user program, assign global

variable to DO.Error Code and Module Error Code. Refer to the manual of the compact

system or module for more details.

Use of Analog Outputs

Perform the following steps to write  a value in the user program to an analog output

1. Define a global variable of type INT containing the value to be output.

2. Enter an appropriate value, when defining the global variable.

3. Assign the global variable the Value [INT] -> channel value of the output.

5

In the user program, program a safety-related fault reaction using the error code -> Error

Code [Byte].

The global variable provides values to the analog output.

To get additional options for programming fault reactions in the user program, assign global

variable to AO.Error Code and Module Error Code. Refer to the manual of the compact

system or module for more details.

8.2.5

Generating the Resource Configuration

To generate the code for the resource configuration

1. Select the resource in the structure tree.

2. Click the Code Generation button located on the Action Bar or select Code Generation

on the context menu.

The Start Code Generation dialog box appears.

3. In the Start Code Generation dialog box, click OK.

An additional Start Code Generation opens, shows the code generation progress and

disappears. The logbook contains a row informing about the code generation result.

4. With the resource still selected, select the Version Comparison: function on the Extras

menu.

The Version Overview dialog box opens. It displays the CRC for the generated code.

5. Click Export.



  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • Reason RT431 GPS Precision-Time Clock GE
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch