Omron Relay G9SX-GS226-T15-RT
USB-Serial Conversion Cable
Applicable OS
Applicable software
Applicable models
Windows XP/Vista/7/8/10 *1
CX-Thermo version 4.5 or higher
(Version 4.61 or higher is required for the
E5CC-U, Version 4.65 or higher is required
for the E5CC-B *3.)
E5@C-T Series, E5@C Series, and E5CB Series
USB interface standard Conforms to USB Specification 2.0.
DTE speed
38400 bps
Connector
specifications
Power supply
Computer: USB (type A plug)
Digital Temperature Controller:
Special serial connector
Bus power (Supplied from USB host controller.)*2
Power supply voltage 5 VDC
Current consumption 450 mA max.
Output voltage
Output current
Ambient operating
temperature
4.7±0.2 VDC

(Supplied from USB-Serial Conversion Cable
to the Digital Temperature Controller.)
250 mA max.
(Supplied from USB-Serial Conversion Cable
to the Digital Temperature Controller.)
0 to 55°C (with no condensation or icing)
Ambient operating humidity 10% to 80%
Storage temperature-20 to 60°C (with no condensation or icing)
Storage humidity
10% to 80%
Altitude
Weight
2.000 m max.
Approx. 120 g
Windows is a registered trademark of Microsoft Corporation in the
United States and or other countries.
*1.CX-Thermo version 4.65 or higher runs on Windows 10.
*2.Use a high-power port for the USB port.
*3.CX-Thermo version 4.67 or higher is required for the E5CC-B
linear current output type.
Note: A driver must be installed on the computer. Refer to the Instruction
Manual included with the Cable for the installation procedure.
Communications Specifications
Transmission line
connection method RS-485: Multidrop
Communications
RS-485 (two-wire, half duplex)
Synchronization method Start-stop synchronization
Protocol
Baud rate *
CompoWay/F, or Modbus
9600. 19200. 38400. or 57600 bps
Transmission code ASCII
Data bit length *
Stop bit length *
7 or 8 bits
1 or 2 bits
Component
Communications *1
Copying *2
| IS200AEBMG1A GE Control Card w/CIMPLICITY |
| IS200AEBIH1ADC GE Control Card w/CIMPLICITY |
| IS200AEADH1A GE rectangular circuit board |
| IS200AEAAH1CPR GE rectangular board |
| IS200AEAAH1C GE printed circuit board |
| IS200AEAAH1AAA GE Speedtronic Mark VI Printed Circuit Board |
| IS200AEAAH1A GE printed circuit board |
| IS200ADIIH1AAA GE AUXILIARY DRIVE TO ISBUS INTERFACE BOARD |
| IS200ADIIH1A GE Dual Channel/Dual Port Input Output Module |
| IS200ACLEH1BCB GE Mark VI (Mark 6) Speedtronic Control card |
| IS200ACLEH1A GE Application Control Layer Module |
| TU811V1 3BSE013231R1 Compact Module Termination Unit 28 signal terminals ABB |
| IS200ACLAH1A GE Application Control Layer Module |
| 2711-PT10C21D8S PanelView Plus 7 Standard Terminals Allen Bradley |
| DS200FGPAG1A GE Gate Pulse Amplifier Board |
| DS2020DACAG2 GE 115/230 VAC input to 126 VDC output |
| DS2020DACAG1 GE AC to DC Converter Power Supply |
| IS200EXMDG1A GE Exciter MD Feedback Board |
| IS200EXAMG1A GE Bridge and Protection Module |
When Digital Temperature Controllers are
connected, set points and RUN/STOP
commands can be sent from the Digital
Temperature Controller that is set as the
master to the Digital Temperature
Controllers that are set as slaves.
Slope and offsets can be set for the set point.
Number of connected Digital Temperature
Controllers: 32 max. (including master)
When Digital Temperature Controllers are
connected, the parameters can be copied
from the Digital Temperature Controller that is
set as the master to the Digital Temperature
Controllers that are set as slaves.
MELSEC is a registered trademark of Mitsubishi Electric Corporation.
KEYENCE is a registered trademark of Keyence Corporation.
*1.A Temperature Controller with version 1.1 or higher is required.
A Temperature Controller with version 2.1 or higher is required for
the FX Series or the KV Series.
*2.Both the programless communications and the component
communications support the copying.
Current Transformer (Order Separately) Ratings
E54-CT1
E54-CT3
E54-CT1L
E54-CT3L
Dielectric strength 1.000 VAC for 1 min 1.500 VAC for 1 min
Vibration resistance
Weight
Accessories
50 Hz, 98 m/s2
E54-CT1: Approx. 11.5 g
E54-CT3: Approx. 50 g
E54-CT3 Only
Armatures (2)
Plugs (2)
E54-CT1L: Approx. 14 g
E54-CT3L: Approx. 57 g
None
Heater Burnout Alarms and SSR Failure Alarms
CT input (for heater
current detection)
Models with detection for single-phase
heaters: One input
Models with detection for singlephase or
three-phase heaters: Two inputs
Maximum heater current 50 A AC
Input current
indication accuracy ±5% FS ±1 digit max.
Heater burnout alarm
setting range *1
0.1 to 49.9 A (in units of 0.1 A)
Minimum detection ON time: 100 ms *3
SSR failure alarm
setting range *2
0.1 to 49.9 A (in units of 0.1 A)
Minimum detection OFF time: 100 ms *4
*1.For heater burnout alarms, the heater current will be measured
when the control output is ON, and the output will turn ON if the
heater current is lower than the set value (i.e., heater burnout
detection current value).
Error detection
Flow control
Interface
Retry function
Vertical parity (none, even, odd)
Block check character (BCC) with
CompoWay/F or CRC-16 Modbus
Communications buffer 217 bytes
Communications
response wait time
0 to 99 ms
Default: 20 ms
*The baud rate, data bit length, stop bit length, and vertical parity can
be individually set using the Communications Setting Level.
Communications Functions
Programless
communications *1
You can use the memory in the PLC to read and write
E5@C parameters, start and stop operation, etc. The
E5@C automatically performs communications with
PLCs. No communications programming is required.
Number of connected Digital Temperature
Controllers: 32 max. (Up to 16 for the FX Series)
Applicable PLCs
OMRON PLCs
CS Series, CJ Series, CP Series,
NJ Series, or NX1P
Mitsubishi Electric PLCs
MELSEC Q Series, L Series, FX3 Series,
or iQ-R Series
KEYENCE PLCs
KEYENCE KV Series
*2.For SSR failure alarms, the heater current will be measured when the
control output is OFF, and the output will turn ON if t