IS200EISBH1A

Part Number IS200EISBH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series EX 2100e Function Module Availability In StockIS200EISBH1A is an Exciter ISBus Board and is part of the GE EX2100. 

The Exciter ISBus Board (EISB) is a unique communication board for the M1, M2, and C controllers. It receives and transmits fiber-optic feedback signals to the DSPX controller via the control backplane, and it also communicates between the DSPX and the tool and keypad ports via the backbone connector using RS-232C. EISB also includes ISBus interface electronics for redundant exciters. 

 IS200EISBH1A Functional Description ISBus is a GE proprietary communications interface that is used here to transfer data between the exciter's M1, M2, and C controllers. EISB is a single-slot, 3U high module found in the control rack beneath the DSPX. It accepts current and voltage signals from the generator field (and the Exciter if necessary) via fiber-optic connectors on the front panel, and receives and transmits signals to the Ground Detection module. 

 Application Data EISB has no LED indicators, jumpers, or fuses. 

 Connectors The following fiber optic connectors are located on the board's front panel for receiving and transmitting variable frequency signals: EDCF board generator field dc voltage input dc Generator Field The EDCF board's current input EDCF Exciter Voltage input (optional) EDCF exciter current input (optional) Voltage input for Ground Detector Voltage output from the Ground Detector A reset switch is also recessed behind a hole in the lower part of the front panel. Optical Connectors On the front panel, there are two groups of four optical receive receptacles. In the lower section, there is a two-piece group consisting of one optical receiver and one transmitter. Keypad and Tool For communication with the keypad, EISB has an RS-232C driver. It provides the power source with +24 V dc and 24 V dc return from the backplane. 

EISB also includes an RS-232C driver for communicating with a computer via the tool port. The data rates range between 1200 and 38.4 KBaud. IS200EISBH1A Board Replacement To replace a board in a control rack while it is offline Ensure that the exciter has been deactivated; Open the control cabinet door and ensure that the power indicators on the EPDM and EPSM power supplies, as well as the controller's LEDs, are turned off. 

Disconnect the fiber-optic cables from the EISB board's front. Make sure they are labeled correctly for reassembly. Carefully remove the DSPX board and its attached EISB board from the control rack, as shown below: Loosen the screws near the ejector tabs at the top of the DSPX faceplate and the bottom of the EISB faceplate. (The screws in the faceplate are captive and should not be removed.) Remove the DSPX and EISB by pulling up on the ejector tabs. Gently pull both boards from the rack with both hands. Remove the DSPX from the top of the EISB and replace it with the new EISB board. Place the replacement DSPX and EISB boards in the appropriate rack slot. Begin seating the boards by firmly pressing the top and bottom faceplates with your thumbs at the same time. Finish seating the boards in the slot by tightening the screws at the top and bottom of the faceplate assembly alternately. Screws should be tightened evenly to ensure that the boards are seated squarely. Reconnect all communication cables that were removed from the old module.EXCITER IN-SYNCH-BUS

Related models

0880001-01

104X905BA603

12A0-0103-A3

12HFA51A42H

12HGA11J52

269 PLUS-D/O-100P-125V

369-A200

369B1860G0026

369B1860G0030

369-C100

369-C101

369-HI-0-0-0-0

369-HI-0-M-F-E-0

369-HI-R-M-0-0-0-E

369-HI-R-M-0-E-0

  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System