Description
IS200JPDFG1A - DC PMD CARD

Part Number IS200JPDFG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200JPDFG1A is a Power Distribution Board developed by GE. The JPDF board accepts redundant 125 V dc power inputs and distributes power to other system boards. JPDF operates on a floating dc bus centered on Earth rather than a grounded system. This detects system ground faults and has a non-hazardous live 125 V dc rating. IS200JPDFG1A Features Input 125 V dc battery power is connected to a terminal board on the module. Before being connected to the board via the J1 connector, the power is routed through a 125 V dc 30 A circuit breaker and line filter. The alternating current voltage is then routed to three fused non-switched outputs and six fused switched outputs. The alternating current power is routed through the board to the DACA modules, where it is converted to direct current power. DC power is returned to JPDF and combined with the battery power input. JPDF can operate with any combination of one or more active inputs, resulting in a high-reliability 125 V dc power source for the control system. The JPDF module provides full status feedback via a PPDA I/O pack connection. Feedback includes detection of bus magnitude, ground faults, and excessive ac voltage on the dc bus. Each fused branch circuit is checked for the presence of output power. Installation The module is vertically mounted on a metal back base in a PDM cabinet. The JPDF sheet metal must be connected to the system's protective earth (PE). Terminals DCHI and DCLO receive input battery power. Ac power is applied to JAF1 when one or two DACA modules are used, typically from a JPDB module. JZ2 and JZ3 connectors connect DACA modules to JPDF. The system's output circuits are connected as documented. A 50-pin ribbon cable from JPDF connector P1 to the P2 connector on the board containing PPDA is required for a power distribution system with a PPDA power diagnostic I/O pack. Using the P2 connector, this connection can be extended to other core PDM boards. Ground Fault Detection The module supports the use of a dc bus with a high resistance that is centered on ground potential. This configuration detects a ground fault when the positive or negative bus voltages reach ground potential. It includes separate voltage feedback sensing for positive and negative power with respect to ground to support this arrangement. When the feedback is connected to a PPDA I/O pack, the system detects ground faults. The resistance used to center the dc bus on ground determines the sensitivity of ground detection and the ground fault currents that can flow. It has centering resistors chosen by jumper JP1. If centering resistance is provided elsewhere, the JPDF jumper should be left open. JPDF is then designed to introduce the least amount of centering resistance into the system. JP1 should be closed if JPDF is providing the centering function. Only one JPDF module should have a closed JP1 jumper if two are used. Operation Terminals DCHI and DCLO are powered by a dc battery. It then passes through a 30 amp dc circuit breaker and into a filter assembly located beneath the IS200JPDF circuit board. The filtered output is then routed to the JPDF circuit board via a series diode. The JAF1 connector receives alternating current power. The 115/230 V alternating current is routed to two connectors, JZ2 and JZ3, and then out to two DACA modules. The DACA modules convert alternating current to direct current (125 V dc). DC power returns to JPDF via the same JZ2 and JZ3 connectors, where it is combined with battery power if present.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

IS200JPDFG1A technical specification

General electric manufacturing company

SeriesMark VI Speedtronic

The part number is 200JPDFG1A.

Functional abbreviations

Function description DC PDM card

PCB coating ordinary coating

IS200JPDFG1A is an ag component as a part of Mark VI system. The system is a part of the long-running Speedtronic series, which was created and developed by General Electric Company for gas/steam turbine management. For more than 30 years, various systems named after Speedtronic have been used for heavy turbine management. Mark VI is one of the last systems released, including Ethernet communication and operating interface based on Windows PC. This is the Mark VI turbine control system series to which 200JPDFG1A PCB belongs. According to its complete GE series name, you may have guessed that this series is specially suitable for the management system and control mode of GE-compatible automatic drive components for gas, wind and steam turbines. In this case, the Mark VI series, which includes the larger Mark VI series of IS200JPDFG1A products, is a considerable improvement over the previous Mark V turbine control system series, because the Mark V series has specific applications only in a more limited range of gas and steam turbine products.

Hardware tips and specifications

IS200JPDFG1A is a part of IS2020JPDF power supply module, which consists of circuit board, metal plate structure with DC circuit breaker, input filter, current limiting resistor and series diode. IS200JPDFG1A can provide connection for two DACA modules if necessary. IS200JPDFG1A board is used to distribute DC power to DC. IS200JPDFG1A uses ribbon cable connection, and carries out system feedback such as DC bus voltage and ground fault detection through PPDA board. IS200JPDFG1A has six toggle switches on a line. Three of them include a warning label that says "Attention, wait 30 seconds after cutting off the power supply". To recharge. IS200JPDFG1A has 18 fuses, and each fuse has its own rated power. It has 14 plug connectors, including a 2-bit plug (10,) a 12-bit plug (2,) and a 9-bit and 5-bit plug. IS200JPDFG1A includes a metal film resistor, a box capacitor, a ceramic capacitor, a TP test point and a transistor. Components are marked with reference marks. For more information about the motherboard and its components, please refer to GE publication GEI-100613. Most of the mentioned resistors, diodes, application specific integrated circuits and various types of capacitor components allocated to normal Mark VI series components of IS200JPDFG1A printed circuit board products only exist as standard components of Mark VI series, which are particularly important for voltage protection and regulation process.

IC697MDL740

IC670PBI001

IC698CHS117C

DS200TCQAG1BHF

IS200AEPCH1ABC

IC697MDL250

IC697MDL250

760-P1-G1-S1-LO-A20-R

SR489-P5-LO-A20-E

IC670CHS001E

IC697MDL653

IS200VTCCH1CBB

VMIVME-4150

  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives