KONG -Y
NameDescriptionContent
Location:
product
IS220PSFDH1A - IO PACK, 335V POWER SUPPLY
❤ Add to collection

IS220PSFDH1A - IO PACK, 335V POWER SUPPLY

IS220PSFDH1A - IO PACK, 335V POWER SUPPLY
U.S.$5920.00
U.S.$458.00
U.S.$435.10
U.S.$425.94
Weight:3.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS220PSFDH1A - IO PACK, 335V POWER SUPPLY

Part Number IS220PSFDH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS220PSFDH1A is a Flame Detector Power Supply manufactured by General Electric as part of the Mark VI Series used in gas turbine control systems. The primary gas turbine trip protection (TRPG) terminal board is normally mounted above the Flame Detector Power Supply (PSFD). A power distribution board provides 28 V dc as the source power (JPDL). 335 V dc, 5 mA is the output's rated rating. Up to eight flame detectors can be powered by three power supplies linked in a diode-ORed, TMR arrangement to the TRPG's J3, J4, and J5. Should the other two power supplies fail, each supply has enough power to operate all eight flame detectors. The PSFD's primary characteristics are as follows: Convectional cooling, which uses no cooling fans The ambient temperature is between -30 and 65  (-22 to 149 oF) Input of 28 V dc 5% (26.6 to 29.4 V dc) Unregulated output varies by 5% depending on the input (318 to 352 V dc) Isolation at 1700 V DC Protection against output over-voltage A 335 V dc attenuated test point pair Output Three troubleshooting LEDs External diodes can be used to diode-OR the outputs. A 7 mA dc output current limit The inrush current for soft start hot swap input is capped at 550 mA. Input filtering minimizes the sensitivity to input interference and limits emissions. INSTALLATION OF FLAME DETECTOR POWER SUPPLY Install the mounting plate for the PSFD after firmly mounting the TRPG. This mounting is typically located above the TRPG on the upper level. The mounting plant must be linked to chassis ground, commonly FE, in order to reduce the risk of electrical shock (Field Earth). Using the housing's threaded studs, mechanically secure the PSFD. On the mounting plate, the studs slip into mounting brackets. Connect the PSFD 2x2 connection P2 and J3, J4, or J5 on the TRPG with the 335 V dc cable. Connect the 1x3 connector P1 on the side of the PSFD to supply 28 V dc power to it. This connector has an inherent soft-start feature that controls current inrush on power application, thus it is not essential to insert it with the power disconnected from the cable. OPERATION: The PSFD converts 28 V dc to 335 V dc. Current-limited and hot-swap compatible, the 28 V dc input. Transformer isolation separates the floating output from the input. A fixed ratio push-pull converter with an unregulated switching architecture is used. The input is also hot swappable, and the input and output are both current limited. The 25 kHz switching power supply architecture is push-pull with no feedback or an open loop. According to the input voltage, the output rises and falls. The push-pull transformer has a 1:12 turns ratio to increase the 28 V dc input to 336 V dc. Diode drops further reduce the output voltage by 1.5 V dc, leaving 334 to 335 V dc. Because the power stage's current capacity is substantially higher than the necessary load current, the load control is still good even in this open loop design. Both overcurrent and inrush current is protected by the input circuit breaker. The breaker modulates a series pass FET on and off during current limiting to reduce power loss. If connected to a P28 V dc bus that is active, the PSFD can be hot-plugged and won't interfere with other delicate loads. The fast-acting circuit breaker stops a short circuit from spreading across the 28 V dc bus if a circuit failure and short circuit happen downstream of the circuit breaker. The 28 V dc bus's exposure to noise is decreased by an EMI filter. After the input connector, a 33 V transform shields the PSFD from voltage spikes and errant reverse bias connections. Even during a direct short, the output limiter limits the current to 7 mA. Even in an environment that is , the output can remain shorted indefinitely. At the output, transient protection is provided by a 385 V MOV. DIAGNOSTICS: A differential pair of test points allow for the local monitoring of the output voltage. A 100:1 attenuator that is referred to as the chassis for security connects the positive and negative test points to the positive and negative outputs, respectively. There is no risk of electric shock when touching any test site. In addition, a permanent short to the chassis is possible at each test point. Both TP POS (inboard) and TP NEG are used to identify the test points (outboard). Rotating the top round plastic cover will allow you to reach the test spots. Three status LEDs are seen on the PSFD: At 6-7 mA, the Current Limit, Red, DS3 switch turns on. P335 Out, Green, DS2 - The output could have excessive voltage. This LED cannot reveal the exact voltage level. P28 In, Green, DS1 - The input has voltage. This LED cannot reveal the exact voltage level. The input and output LEDs only signal the existence of input or output voltage and do not represent any specific voltage level. Similar to the voltage limit LED, the current limit LED does not measure the over-current magnitude and is just intended to serve as an indication. The signal path for the activation signal and the current limit LED are connected in series. In the event that the current limit LEDs malfunction open, a circuit gets around the LED and the limiter keeps working. Each PSFD's output voltage is attenuated and detected on the TRPG terminal board. The PTUR I/O pack continuously monitors the measured voltage. An alarm is announced in the ToolboxST program or Alarm Viewer in a TMR system if any one of the three PSFDs cannot supply 335 V dc.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

DS200DCFBG1BLC

MS90376-12Y

VMIVME-7807RC

SERVOSTAR 310

IS200ERIOH1AAA

IS220PSCAH1A 336A4940CSP9

D20-PS LFDSC143-4000

IS200TDBTH6ABC

DS200SHVMG1AGE

IS2020RKPSG3A

DS200SHVMG1AFE

IC660ELB912

IS220PPRFH1A

IC698PSA350

HYDRAN M2

IC693PWR321

IS215VCMIH2BB IS200VCMIH2BCC

  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives