Description
IS200TBTCH1C

Part Number IS200TBTCH1C Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200TBTCH1C is a thermocouple terminal board developed by General Electric. It is a part of the Mark VIe control system. The thermocouple terminal board accommodates up to 24 thermocouple inputs of types E, J, K, S, or T. These inputs are connected to two barrier-type blocks on the terminal board, and communication with the I/O processor is established through DC-type connectors. In the Mark VIe system, the PTCC I/O pack collaborates with the board, supporting simplex, dual, and TMR (Triple Modular Redundant) systems. In simplex configurations, two PTCC packs can be plugged into the TBTCH1C, providing a total of 24 inputs. When using the TBTCH1B, one, two, or three PTCC packs can be connected, supporting a range of system setups, although only 12 inputs are accessible in this configuration. Installation Mounting the Removable Terminal Blocks: The first step in the installation process involves mounting the removable terminal blocks on the terminal board. These blocks are instrumental in connecting the thermocouples to the system. They are secured in place using two screws to ensure stability and a reliable connection. Connecting Thermocouples: Thermocouples, which are temperature sensors, are then wired directly to the terminals on these blocks. The terminal blocks have 24 terminals, each capable of accepting wires up to 12 AWG in size. 

These terminals are where the wires from the thermocouples are securely attached. Shield Terminal Strip for Grounding: On the left side of each terminal block, there is a shield terminal strip that is attached to chassis ground. This strip plays a crucial role in grounding and shielding the thermocouple wires, preventing interference and ensuring accurate temperature measurements. Cabling: Mark VIe systems utilize I/O packs that plug into the J-type connectors on the thermocouple terminal board. The number of cables or I/O packs needed depends on the level of redundancy required for the system. Redundancy ensures system reliability by providing backup components. Operation Flexibility with Thermocouple Inputs: It offers remarkable flexibility as it can accommodate 24 thermocouple inputs, whether they are grounded or ungrounded. This adaptability allows it to work effectively with a variety of temperature-sensing setups. Long-Distance Connectivity: One notable feature is its ability to handle thermocouple inputs located up to 300 meters (approximately 984 feet) away from the turbine control panel. This long-distance capability enables the placement of temperature sensors in various parts of the system while maintaining reliable communication with the control panel. Cable Resistance Tolerance: To ensure accurate and dependable data transmission, it is designed to tolerate a maximum two-way cable resistance of 450 ohms. This tolerance ensures that cable length and resistance variations do not compromise the quality of the temperature data collected. High-Frequency Noise Suppression: Noise in electrical signals can interfere with temperature measurements. TBTC addresses this concern by incorporating high-frequency noise suppression mechanisms. These mechanisms help filter out unwanted electrical noise, ensuring that the temperature readings remain precise and free from interference. Cold Junction Reference Devices: Equipped with two cold junction reference devices These devices are essential for compensating for temperature variations at the junction where the thermocouple wires connect to the terminal blocks. By providing reference points, they enable accurate temperature measurements, even in varying environmental conditions. Analog-to-Digital Conversion in the I/O Processor: The analog-to-digital conversion process, which translates analog temperature signals into digital data, occurs in the I/O processor. This step is vital in preparing the temperature readings for further processing and analysis. Linearization for Different Thermocouple Types: Different thermocouple types exhibit unique temperature-voltage relationships. To ensure accurate temperature readings, the TBTC handles the linearization of these relationships for individual thermocouple types. This means that the temperature data is adjusted to reflect the specific characteristics of the thermocouples in use. Product Attributes Reference Junction Temperature Measurement: Cold junction compensation is achieved by measuring the reference junction temperature at specific locations on each H1C terminal board. This reference junction, also known as the cold junction, is a crucial reference point for thermocouples. Accurate measurement of its temperature is essential for compensating temperature readings. TMR H1B Board's Multiple Cold Junction References: In the case of the TMR H1B board, there are six cold junction references available. Please contact us. Gmail: yy4291644@gmail.com   Enterprise mailbox: ivy@kongjiangauto.com 

 

These references serve as additional reference points for compensation. However, it's important to note that only three of these references are available when associated with packs. These references are invaluable for enhancing the accuracy of temperature measurements. Cold Junction Temperature Accuracy: Achieving precise temperature measurements is a primary objective of cold junction compensation. The system's cold junction temperature accuracy is specified at 2 degrees Fahrenheit. This level of accuracy ensures that temperature readings are highly reliable and free from significant errors. Fault Detection Through High/Low Limit Checks: To further enhance the reliability of temperature measurements, hardware-based high and low limit checks are employed for fault detection. These checks are designed to identify any temperature readings that fall outside acceptable boundaries, indicating potential errors or faults in the system. Comprehensive Monitoring of Key Parameters: The monitoring process within the system is extensive and includes readings from all temperature sensors (TCs), cold junctions (CJs), calibration voltages, and calibration zero readings. This comprehensive monitoring approach ensures that all critical parameters are constantly assessed and that any deviations from expected values are promptly detected.THEROCOUPLE TERMINAL

Related models

DS200SHVMG1AFE

IC660ELB912

IS230TVBAH2A

IS215VCMIH2BB IS200VCMIH2BCC

IS210MACCH1AGG

SR489-P5-LO-A20-E

MVR1600-4601

D20 EME 2400-21004

IC697MDL350

8101-HI-TX-02

IC698PSA100

IC698RMX016-ED

IC660BBD025

531X303MCPARG1

DS200FSAAG1ABA


  • Tricon 8120E card is in stock.
  • NE870 Network Router ABB 3BSE080239R1
  • ALSTOM V4561484-0100 Amplifier Module Rev 7 Pcb Circuit Board
  • Model 10959-201 and -203 Wall-Mount Audio Messenger Interfaces
  • HIMA X-SB 01985210207 24VDC System bus module
  • HIMA X-FAN 18 03 High-efficiency cooling plate fan
  • HIMatrix F3 AIO8/4 01 HIMA Compact Controller
  • 3BHE039770R0102 PP D539 A102: AC 800PEC Contr. Device
  • ABB CMC 70, Controller, SW-Vers. 1.61/2.11
  • GE SR760-CASE 750/760Feeder Management Relay® Instruction Manual
  • ABB REG670 C30 Version 2.0 General Information
  • REF543KM127BAAA ABB FEEDER TERMINAL
  • Danaher driver SAM-DA-400/480-07N-P4N-F
  • GE FANUC/ALSTOM LC106-1- LE108 LC105 LC106 Spot model
  • ALSTOM AB121丨AY00000000266/B technical parameter
  • GE ALSTOM LE109A-1 control card data
  • GE ALSTOM IR139-1丨063022350 丨80801419 Control card. data
  • Alstom Control Set-UT150-1 Kongjiang-spot
  • ALSTOM AL132丨AL132A Control Card
  • PM1118丨ABB PM118-7BPM1118 MAGNET (NEO) .50LG
  • DEIF DLQ72-PC-PY ROLLS-ROYCE K85240 PITCH INDICATOR 10V
  • Rolls-Royce Marine R10I53S/R10I53S Panel Computer 98H0101A0000I Rev 1.9
  • ROLLS-ROYCE P001240-1 display REV 2
  • ROLLS-ROYCE RRDIO15 I/O ALARM MODULE
  • Rolls-royce UN930 Digital Display Controller 24V
  • ROLLS-ROYCE MARINE LAUER LCA 325.P2 PROFIBUS-DP NET DISPLAY PANEL UN924
  • ROLLS-ROYCE MARINE AS 5880-PC1002 STEERING GEARS-TENFJORD PCB card
  • ROLLS-ROYCE UN31 ECR panel 000127603
  • Rolls-royce ship AS UN991.1 distributing plate
  • ROLLS-ROYCE 5045 K THRUSTER CONTROLLER PANEL
  • Rolls-Royce SLIO 02 Canman controller network
  • Rolls-Royce E-1071 automatically displays 07918 B UN 921 ECR 24VDC
  • ROLLS ROYCE PCC1030C ULSTEIN panel controller card
  • ROLLS-ROYCE KAMEWA PROPELLERS control room panel basic R160637A
  • ROLLS-ROYCE UN925 Panel Controller
  • Rolls-royce Marine AS UN921 OPRETOR panel
  • Rolls-Royce Marine r10I53s/R10I53S Panel Computer 98H0101A0000I
  • ROLLS-ROYCE H1111.0104 ocean controller P/N:75669
  • Rolls-Royce H1111.0203 Marine Controller Version 2.2
  • Rolls-Royce H1111.0102 Marine Controller
  • Rolls-Royce H1127-0101 Marine Controller 00068308H6045/433
  • Rolls-Royce H1111.0103 Marine Controller 75669 Version 2.2
  • EMERSON KJ3221X1-BA2 VE4035S2B1 ATEX Instruction Sheet
  • EMERSON VE4017P0 M-series FOUNDATION™ Fieldbus I/O
  • A6740 16-Channel Output Relay Module for the AMS 6500 Machinery Health Monitor
  • EMERSON A6120 Protection Cards for AMS 6500 Classic Systems
  • A6000 series A6125 electric vibration monitor Emerson
  • EMERSON A6000 series control card A6410
  • EMERSON A6370 Overspeed Protection Monitor
  • ABB 3BHB015651P0001 DKTFM418B Power converter assembly
  • Westingouse Ovation 5X00500G01 Speed detector module
  • Emerson 5X00875G01 Analog input EMOD module
  • UNIOP ETT-VGA-0045 HMI touch unit with colour graphic display and VGA resolution. Available with high-quality TFT
  • General Electric Mark VI series IS200JPDBG1A IS200JPDBG1ABB printed circuit
  • General electric IS200EDISG1A distribution board
  • IS400TDBTH6A Mark* VIe control system Extended product life cycle description
  • DS200DCFBG1BLC General Electric Power Supply Board
  • 5485C Velocity Sensor Metrix
  • ABB 3BSE031155R1 BC810K02 CEX-bus Interconnection Unit
  • DCS602-0250-51-15 ABB DCS 600 Overload Capability
  • DCS602-0520-51/15 ABB Permanent drive
  • 853-032776-001 Lam Research Paddle Lifter
  • Modbus Plus Communication Module MVI56-MBP
  • PLC board (head) module KEBA CPU IP70
  • DS200DSFBG1A Driver/Shunt Feedback Board technical specifications
  • DS200DPCAG1ADB IOS + Power Connect Board Technical Specifications
  • DS200DPCAG1A IOS & Power Connect Card Assembly
  • Hirschmann MM20-P9P9T1T1SAHH Media Converters
  • Hirschmann MM20-P9P9P9P9SAHH In installation instructions
  • Hirschmann MM4-2TX/SFP Media Converters
  • Hirschmann MM4-4TXSFP-datasheet
  • Hirschmann MM3-1FXL23TX1_techdata MM3-1FXL2/3TX1
  • Hirschmann MM3-4FXS2 PowerMICE series industrial switch products
  • Hirschmann MM3-2FXS2/2TX1 Media Converters
  • MM3-1FXM2/3TX1 Hirschmann Ethernet & Communication Modules
  • Hirschmann MM3-4TX5 Media module
  • Hirschman MM2-2FXM3/2TX1 Media Module article will analyze the technical features of this product in detail
  • Hirschmann MM2-4TX1 Performance parameters of compact and modular managed Ethernet switch
  • MS4128-L3E ATEX Power mouse, modular, managed industrial Ethernet switch
  • Hirschmann MS4128-L2P ATEX 943009101, Power MICE, modular, managed Industrial
  • Hirschmann Managed Ethernet Switch MM20-M2M2T1T1SAHH
  • Hirschmann MM20-T1T1T1T1SZHH Managed Ethernet switch
  • Hirschmann MM20-M4T1T1T1SAHH Media converter
  • Detailed explanation of Hirschmann GMM20-mmmmmev9HHS9 xx.x.xxx Ethernet module
  • Hirschmann MM20-M2M2M2T1SAHH Management Ethernet Switch Function and Configuration Guide
  • Product introduction and technical specifications of Hirschmann MM20-M2M2M2M2EAHH media converter
  • Hirschmann MM20-M4M49999TAHH Media converter
  • Hirschmann MM20-Z6Z6Z6Z6TAHH Media converter
  • Media converter MM20-M2M29999EAHH Data
  • Media converter MM20-G2T1T1T1SAHH Hirschmann
  • Hirschmann Media converter MM20-M2T1T1T1TAHH
  • Hirschmann Ethernet module GMM GMM20-VVVVVVVVSY9HHS999.9.XX
  • Managed Ethernet Switch MM20-M4M4M4M4TAHH
  • Hirschmann Managed Ethernet Switch MM20-M2M2T1T1SSHH
  • Hirschmann Managed Ethernet Switch MM20-Z6Z6Z6Z6SSHH
  • Media converter MM20-T1T1T1T1TAHH Hirschmann
  • Hirschmann Media converter MM20-M4M4T1T1EAHH
  • MM20-M4M4M4M4EAHH Hirschmann Media converter
  • Hirschmann Media converter MM20-M2M2M2M2SAHH
  • Hirschmann Managed Ethernet Switch MM20-S2S2T1T1SYHH
  • ABB SDCS-POW-4 POWER SUPPLY
  • AMAT 0090-35032 ARSINE DETECTOR 0-1000PPB
  • SMC XLFD-100D-X1236 high vacuum valve 0.4 ~ 0.7MPa 5 ~ 60°C
  • 50DW412745 Control Module United Technologies Carrier
  • Carrier 50DW404638 Control module CEAS430189-02
  • TRICONEX 2481 I/O Module
  • WARNER ELECTRIC HMCS2000-PRG Programmer
  • WARNERELECTRIC MCS2000-ECA Digital control
  • Related Manuals for WAGO WAGO-I/O-IPC 758-870 and 58-873Series
  • IOC4T-RLC16 Vibro-Meter company VM600 system and sensor technical data
  • MEGGITT VIBRO-METER 200-510-076-114 VM600 MPC4 Descriptive data
  • IPC704 Signal conditioner MEGGITT VIBRO-METER IPC704 244-704-000-032 AMP
  • GSI127 galvanic separation unit MEGGITT VIBRO-METER GSI 127 244-127-000-017 A1-B02 MODULE
  • ABB Relion® 650series REC650/REL650/RET650/REB 650/REQ 650
  • Rexroth Sercos III analog, axis module R-ILB S3 AI12 AO4 SSI-IN4
  • DS200DMCBG1ABB DOS DUP Processor Board
  • DS200DMCAG1AAA Gen/Log/Key Interface Board
  • DS200DKLBG1ABB Power Connect Board
  • General Electric DS200DENCF1BDE01 EEPROM with Firmware
  • DS200DDTBG2ABB LCI Auxiliary I/O Terminal Board
  • DS200DCVAG1A DC Power and Instrumentation Board
  • DS200DCPAG1 DC Power Board GE General Electric
  • DS200DCFBG1B DC Feedback Power Supply Board
  • DS200DCFBG1AAA DC Power Feedback Board
  • DS200DACAG1 TC/DC AC/DC Convertor Board
  • DS200CVMAG3AEB Cap/Fuse Voltage Monitor Board
  • DS200CVMAG1AEB Capacitor Voltage Monitor Assembly
  • DS200CTBAG1A Analog Termination Module